W DOC AIRBUS | AMM A320F

Removal of the Inner Line Heater


TASK 30-73-54-000-001-A
Removal of the Inner Line Heater


FIN: 25DW ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
1
CUTTER - THIN BLADE
No specific
1
PLIERS - END-CUTTING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
131GW, 812, 825
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 12-24-38-680-001-A
Draining of the Potable Water System (with Electrical Power)
TASK 12-24-38-680-002-A
Draining of the Potable Water System (without Electrical Power)
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
F Heater-Inner Line ** ON A/C NOT FOR ALL
F Heater-Inner Line ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 30-73-54-680-050-A ** ON A/C NOT FOR ALL
A. Drain the potable water system (Ref. AMM TASK 12-24-38-680-001) or (Ref. AMM TASK 12-24-38-680-002).
Subtask 30-73-54-861-050-A ** ON A/C NOT FOR ALL
B. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 30-73-54-865-050-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VUPOT/WASTE WIP-HEATER-LINE21DWA03
2000VUPOT/WASTE WIP-HEATER-LINE1DWA02
2000VUPOT/WASTE WIP-HEATER-CTL2DWA01
** ON A/C NOT FOR ALL
2000VUPOT WIP-HEATER-LINE21DWA03
2000VUPOT WIP-HEATER-LINE1DWA02
2000VUPOT WIP-HEATER-CTL2DWA01
Subtask 30-73-54-010-050-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 812 of the avionics compartment.
   (2) Open the access door 812.
   (3) Put the ACCESS PLATFORM 2M (6 FT) in position at the FWD cargo-compartment door 825.
   (4) Open the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
   (5) Set the CARGO COMPT LIGHT switch 6LU to the ON position.
   (6) In the forward cargo compartment, remove the sidewall panel 131GW.
4. Procedure
Subtask 30-73-54-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Inner Line Heater
   (1) Disconnect the electrical connector (1).
   (2) Put CAP - BLANKING on the electrical connector and the electrical receptacle.
   (3) Remove the adhesive tape (4) that holds the sleeve (5).
   (4) Remove the sleeve (5).
   (5) Loosen the nut (3).
   (6) Remove the clamps (7).
   (7) Remove the box (8).
   (8) Disconnect the tee (10) from the pipes (9), (11) and (12).
   (9) Remove the inner line heater (2) from the pipe (11) and from the tee (10).
   (10) Remove the tee (10).
   (11) Remove the inner line heater (2) from the pipe (6).
Subtask 30-73-54-020-050-B ** ON A/C NOT FOR ALL
A. Removal of the Inner Line Heater
   (1) Disconnect the electrical connector (1).
   (2) Put CAP - BLANKING on the electrical connector and the electrical receptacle.
   (3) Remove the adhesive tape (4) that holds the sleeve (5).
   (4) Remove the sleeve (5).
   (5) Loosen the nut (3).
   (6) Remove the clamps (11).
   (7) Remove the half box (12) with a CUTTER - THIN BLADE and a PLIERS - END-CUTTING.
   (8) Discard the half box (12).
   (9) Disconnect the tee (8) from the pipes (7), (9) and (10).
   (10) Remove the inner line heater (2) from the pipe (9) and from the tee (8).
   (11) Remove the tee (8).
   (12) Remove the inner line heater (2) from the pipe (6).
[Rev.10 from 2021] 2026.04.01 00:32:54 UTC