Removal of the Potable Water De-icing Sensor
TASK 30-73-18-000-001-A
Removal of the Potable Water De-icing Sensor
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 30-73-18-020-050-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:32:38 UTC
Removal of the Potable Water De-icing Sensor
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121 | AVIONICS COMPARTMENT |
| 131GW, 825 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
CAUTION:
USE ONLY THE GROUND SERVICE NETWORK TO SUPPLY ELECTRICITY BECAUSE THE AVIONICS VENTILATION SYSTEM IS NOT SERVICEABLE. IF YOU ENERGIZE THE AIRCRAFT ELECTRICAL CIRCUITS WITHOUT THE VENTILATION SYSTEM YOU WILL CAUSE DAMAGE TO ELECTRICAL EQUIPMENT.
Subtask 30-73-18-861-050-A ** ON A/C NOT FOR ALL Subtask 30-73-18-865-050-A ** ON A/C NOT FOR ALL B. Open, safety and tag this(these) circuit breaker(s):
Subtask 30-73-18-010-050-B ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 6HQ | D06 |
| 49VU | AIR COND/AVNCS VENT/CTL | 5HQ | D05 |
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
| 123VU | AVNCS VENT/BLOWER/FAN | 1HQ | AD10 |
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AE02 |
| 2000VU | POT/WASTE WIP-HEATER-LINE | 21DW | A03 |
| 2000VU | POT/WASTE WIP-HEATER-CTL | 2DW | A01 |
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) at the FWD cargo-compartment door 825.
(2) Open the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(3) Set the CARGO COMPT LIGHT switch 6LU to ON.
(4) In the FWD cargo compartment, remove the sidewall panel 131GW.
Subtask 30-73-18-010-051-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 2M (6 FT) at the FWD cargo-compartment door 825.
(2) Open the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(3) Set the CARGO COMPT LIGHT switch 6LU to ON.
(4) In the FWD cargo compartment, remove the sidewall panel 131GW.
D. Removal for Access to the Sensor
(1) Remove the clamp (10).
(2) Remove the clamps (7).
(3) Hold the duct (9) and remove the clamp (8).
(4) Remove the duct (9) and discard the O-ring (11).
4. Procedure(1) Remove the clamp (10).
(2) Remove the clamps (7).
(3) Hold the duct (9) and remove the clamp (8).
(4) Remove the duct (9) and discard the O-ring (11).
Subtask 30-73-18-020-050-B ** ON A/C NOT FOR ALL
A. Removal of the Potable Water De-icing Sensor
(1) Cut the tie-down straps (1) that attach the glass wool mat (6) around the sensor.
(2) Remove the glass wool mat (6) from around the clamp sensor assembly (2) and the clamp (3).
(3) Disconnect the two wires of the clamp sensor assembly (2) from the terminal strip.
(4) On the potable water pipe, loosen and remove the screws (4) and (5) from the clamp sensor assembly (2) and the clamp (3).
(5) Remove the clamp (3).
(6) Remove the clamp sensor assembly (2).
(1) Cut the tie-down straps (1) that attach the glass wool mat (6) around the sensor.
(2) Remove the glass wool mat (6) from around the clamp sensor assembly (2) and the clamp (3).
(3) Disconnect the two wires of the clamp sensor assembly (2) from the terminal strip.
(4) On the potable water pipe, loosen and remove the screws (4) and (5) from the clamp sensor assembly (2) and the clamp (3).
(5) Remove the clamp (3).
(6) Remove the clamp sensor assembly (2).