Installation of the Temperature Sensor
TASK 30-73-17-400-003-A
Installation of the Temperature Sensor
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 30-73-17-860-052-A ** ON A/C NOT FOR ALL
Subtask 30-73-17-420-053-A ** ON A/C NOT FOR ALL
Subtask 30-73-17-410-052-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:32:37 UTC
Installation of the Temperature Sensor
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 131 | FORWARD CARGO COMPARTMENT |
| 825 | |
| FOR [10DW] (SENSOR,TEMPERATURE-) | |
| 131HW | |
| FOR [300DW] (SENSOR,TEMPERATURE-) | |
| 131PW, 131RW | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 30-73-00-720-001-A | Functional Test of the Potable Water Ice-Protection |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 30-73-17-860-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
Subtask 30-73-17-010-055-A ** ON A/C NOT FOR ALL (1) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
B. Get Access
(1) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(2) Make sure that the FWD cargo-compartment door 825 is open.
(3) Make sure that the CARGO COMPT LIGHT switch 6LU is at ON.
(4) In the FWD cargo-compartment, make sure that these panel(s) is (are) removed:
(a) FOR [10DW] (SENSOR,TEMPERATURE-)
131HW
(b) FOR [300DW] (SENSOR,TEMPERATURE-)
131RW 131PW
Subtask 30-73-17-865-057-A ** ON A/C NOT FOR ALL (1) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(2) Make sure that the FWD cargo-compartment door 825 is open.
(3) Make sure that the CARGO COMPT LIGHT switch 6LU is at ON.
(4) In the FWD cargo-compartment, make sure that these panel(s) is (are) removed:
(a) FOR [10DW] (SENSOR,TEMPERATURE-)
131HW
(b) FOR [300DW] (SENSOR,TEMPERATURE-)
131RW 131PW
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | POT WIP-HEATER-LINE | 1DW | A02 |
| 2000VU | POT WIP-HEATER-CTL | 2DW | A01 |
Subtask 30-73-17-420-053-A ** ON A/C NOT FOR ALL
A. Installation of the Sensor
(1) On the potable water pipe, install the clamp sensor assembly (1) and the clamp (2) with the screws (3) and (4).
(2) Tighten the screws (3) and (4).
(3) Remove the CAP-BLANKING from each electrical connector and receptacle.
(4) Make sure that all the electrical connections are clean and in the correct condition.
(5) Connect the two wires of the sensor to the terminal block.
(6) Install the sleeve (5) around the clamp sensor assembly (1).
(7) Make sure that the sleeve (5) is correctly installed around the sensor and the pipes.
(8) Install the velcro tape (6) to attach the sleeve (5) around the clamp sensor assembly (1).
Subtask 30-73-17-865-058-A ** ON A/C NOT FOR ALL (1) On the potable water pipe, install the clamp sensor assembly (1) and the clamp (2) with the screws (3) and (4).
(2) Tighten the screws (3) and (4).
(3) Remove the CAP-BLANKING from each electrical connector and receptacle.
(4) Make sure that all the electrical connections are clean and in the correct condition.
(5) Connect the two wires of the sensor to the terminal block.
(6) Install the sleeve (5) around the clamp sensor assembly (1).
(7) Make sure that the sleeve (5) is correctly installed around the sensor and the pipes.
(8) Install the velcro tape (6) to attach the sleeve (5) around the clamp sensor assembly (1).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 30-73-17-720-052-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | POT WIP-HEATER-LINE | 1DW | A02 |
| 2000VU | POT WIP-HEATER-CTL | 2DW | A01 |
Subtask 30-73-17-410-052-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the panel(s):
(a) FOR [10DW] (SENSOR,TEMPERATURE-)
131HW
(b) FOR [300DW] (SENSOR,TEMPERATURE-)
131RW 131PW
(3) Set the CARGO COMPT LIGHT switch 6LU to OFF.
(4) Close the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
(5) Remove the access platform(s).
Subtask 30-73-17-862-052-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the panel(s):
(a) FOR [10DW] (SENSOR,TEMPERATURE-)
131HW
(b) FOR [300DW] (SENSOR,TEMPERATURE-)
131RW 131PW
(3) Set the CARGO COMPT LIGHT switch 6LU to OFF.
(4) Close the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
(5) Remove the access platform(s).
Temperature Sensor