Removal of the Thermostat
TASK 30-72-11-000-001-A
Removal of the Thermostat
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 30-72-11-861-052-A ** ON A/C NOT FOR ALL Subtask 30-72-11-865-053-A ** ON A/C NOT FOR ALL
Subtask 30-72-11-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:32:17 UTC
Removal of the Thermostat
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | 1 | ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20 |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | SCREWDRIVER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 161DW, 171AL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 25-55-12-000-001-A | Removal of the Aft Cargo-Compartment Partition at FR65 |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 30-72-11-861-052-A ** ON A/C NOT FOR ALL Subtask 30-72-11-865-053-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 30-72-11-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | POT/WASTE WIP-SVCE-PNL | 15DV | D01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | POT WIP-SVCE-PNL | 15DV | D01 |
C. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) in position at potable-water service panel 171AL.
(2) Open the panel and make sure that the drain-control handle is in the NORM position.
(3) Put an ACCESS PLATFORM 2M (6 FT) in position at the aft cargo-compartment door.
(4) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(5) Remove partition 161DW to get access to the thermostat and terminal block 7510VT (Ref. AMM TASK 25-55-12-000-001).
4. Procedure(1) Put an ACCESS PLATFORM 2M (6 FT) in position at potable-water service panel 171AL.
(2) Open the panel and make sure that the drain-control handle is in the NORM position.
(3) Put an ACCESS PLATFORM 2M (6 FT) in position at the aft cargo-compartment door.
(4) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(5) Remove partition 161DW to get access to the thermostat and terminal block 7510VT (Ref. AMM TASK 25-55-12-000-001).
Subtask 30-72-11-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Thermostat
(1) Remove and discard the cable ties from the electrical wires.
(2) Make match marks on all electrical wires before you disconnect them.
(4) Remove the screws (4), the washer (2) and the nut (1).
(5) Lift the thermostat-housing cover (3).
(6) Loosen the threaded-sleeve (7) with a SCREWDRIVER.
(7) Remove the threaded-sleeve (7).
(8) Remove the thermostat-housing (6) from the stud (5).
(1) Remove and discard the cable ties from the electrical wires.
(2) Make match marks on all electrical wires before you disconnect them.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(3) Disconnect the electrical connections (8) with the ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20 from terminal block 7510VT. (4) Remove the screws (4), the washer (2) and the nut (1).
(5) Lift the thermostat-housing cover (3).
(6) Loosen the threaded-sleeve (7) with a SCREWDRIVER.
(7) Remove the threaded-sleeve (7).
(8) Remove the thermostat-housing (6) from the stud (5).
Thermostat 12DV and Thermostat 14DV