Removal of AFT Waste-Pipe Heating Elements
TASK 30-71-58-000-001-A
Removal of AFT Waste-Pipe Heating Elements
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 30-71-58-861-050-A ** ON A/C NOT FOR ALL
Subtask 30-71-58-020-050-A ** ON A/C NOT FOR ALL
(2) Remove and discard the TIE WRAP(S) (4) from the electrical wires of the heater element (8).
(3) Remove the insulation blanket(s) (1) from the heater element (8).
(5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(6) Remove the tank connecting tube (Ref. AMM TASK 38-31-74-000-001).
(8) Remove and discard the Adhesive Tape-- Glass Cloth - (Material No.05TAB1) (7) from the heater element (8).
(9) Remove the heater element (8).
[Rev.10 from 2021]
2026.04.01 00:32:13 UTC
Removal of AFT Waste-Pipe Heating Elements
WARNING:
DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
- FLUSH IT AWAY WITH CLEAN WATER
- GET MEDICAL AID.
ZONE: 160
ZONE: 170
FIN: 71DU ** ON A/C NOT FOR ALL
FIN: 72DU ** ON A/C NOT FOR ALL
FIN: 73DU ** ON A/C NOT FOR ALL
1. Reason for the JobZONE: 170
FIN: 71DU ** ON A/C NOT FOR ALL
FIN: 72DU ** ON A/C NOT FOR ALL
FIN: 73DU ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | 1 | ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20 |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.05TAB1) | Adhesive Tape-- Glass Cloth - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 160 | BULK CARGO COMPARTMENT AFT BULKHEAD OF AFT CARGO COMPARTMENT TO AFT BULKHEAD OF BULK CARGO COMPARTMENT |
| 170 | AFT CAB U/FLOOR COMPT AFT BHD OF BULK |
| 162DW |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 25-55-12-000-001-A | Removal of the Aft Cargo-Compartment Partition at FR65 |
| TASK 38-31-74-000-001-A | Removal of the Waste Tank Drain Line |
| TASK 52-30-00-860-006-A | Open the Bulk Cargo-Compartment Door |
Subtask 30-71-58-861-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 30-71-58-865-053-A ** ON A/C NOT FOR ALL (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 30-71-58-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | POT/WASTE WIP-HEATER-CTL | 32DW | D02 |
| 2001VU | WASTE WIP-HEATER-LINE | 31DU | E04 |
C. Get Access
(1) Open the bulk cargo-compartment door (Ref. AMM TASK 52-30-00-860-006).
(2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(3) Set cargo-compartment light switch 18LU to the ON position.
(4) Remove partition panel 162DW (Ref. AMM TASK 25-55-12-000-001).
4. Procedure(1) Open the bulk cargo-compartment door (Ref. AMM TASK 52-30-00-860-006).
(2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(3) Set cargo-compartment light switch 18LU to the ON position.
(4) Remove partition panel 162DW (Ref. AMM TASK 25-55-12-000-001).
Subtask 30-71-58-020-050-A ** ON A/C NOT FOR ALL
WARNING:
YOU MUST ALWAYS WEAR RUBBER GLOVES WHEN YOU DO THIS PROCEDURE.
A. Removal of a Heater Element (Example) NOTE: The removal procedure is the same for all the heater elements.
(1) Remove and discard the TIE WRAP(S) (4) from the identification and warning labels. (2) Remove and discard the TIE WRAP(S) (4) from the electrical wires of the heater element (8).
(3) Remove the insulation blanket(s) (1) from the heater element (8).
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
CAUTION:
MAKE MATCH MARKS ON ALL THE ELECTRICAL WIRES BEFORE YOU DISCONNECT THEM. INCORRECT CONNECTION OF WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
(4) Disconnect the electrical connections (5) with an ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20. (5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(6) Remove the tank connecting tube (Ref. AMM TASK 38-31-74-000-001).
CAUTION:
BE CAREFUL WHEN YOU REMOVE/INSTALL THE SHRINKABLE SLEEVE.
IF YOU ARE NOT CAREFUL, YOU CAN CAUSE DAMAGE TO THE TUBE.
(7) Remove and discard the SLEEVE - SHRINKING (6) from the heater element (8). (8) Remove and discard the Adhesive Tape-- Glass Cloth - (Material No.05TAB1) (7) from the heater element (8).
(9) Remove the heater element (8).
AFT Waste-Pipe Heating Elements