Removal of the Waste-Water Ice-Protection Control Unit
TASK 30-71-34-000-001-A
Removal of the Waste-Water Ice-Protection Control Unit
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 30-71-34-861-050-A Subtask 30-71-34-865-059-A
Subtask 30-71-34-020-051-A
[Rev.10 from 2021]
2026.04.01 00:31:56 UTC
Removal of the Waste-Water Ice-Protection Control Unit
NOTE: The procedure is the same for all the control units.
ZONE: 130
ZONE: 160
ZONE: 170
FIN: 140DU ** ON A/C NOT FOR ALL
FIN: 15DU
FIN: 23DW ** ON A/C NOT FOR ALL
FIN: 25DU ** ON A/C NOT FOR ALL
FIN: 3DW
FIN: 33DW ** ON A/C NOT FOR ALL
FIN: 35DU ** ON A/C NOT FOR ALL
FIN: 5DU
FIN: 53DW ** ON A/C NOT FOR ALL
FIN: 80DU ** ON A/C NOT FOR ALL
1. Reason for the JobZONE: 160
ZONE: 170
FIN: 140DU ** ON A/C NOT FOR ALL
FIN: 15DU
FIN: 23DW ** ON A/C NOT FOR ALL
FIN: 25DU ** ON A/C NOT FOR ALL
FIN: 3DW
FIN: 33DW ** ON A/C NOT FOR ALL
FIN: 35DU ** ON A/C NOT FOR ALL
FIN: 5DU
FIN: 53DW ** ON A/C NOT FOR ALL
FIN: 80DU ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| FOR [140DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | ||
| FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | ||
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| FOR [15DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | ||
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| FOR [15DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | ||
| FOR [35DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | ||
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| FOR [3DW] (CONTROL UNIT, POTABLE WATERICE PROTECTION-) | ||
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | ||
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 130 | FWD CARGO COMPT AFT BULKHEAD OF AVNCS COMPT TO FWD PRESSURE BULKHEAD OF WING CENTER BOX |
| 160 | BULK CARGO COMPARTMENT AFT BULKHEAD OF AFT CARGO COMPARTMENT TO AFT BULKHEAD OF BULK CARGO COMPARTMENT |
| 170 | AFT CAB U/FLOOR COMPT AFT BHD OF BULK |
| FOR [140DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | |
| 132KW | |
| FOR [15DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | |
| 162CW | |
| FOR [15DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | |
| FOR [35DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | |
| 162CW | |
| FOR [3DW] (CONTROL UNIT, POTABLE WATERICE PROTECTION-) | |
| 132JW | |
| FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | |
| 131MW | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| FOR [140DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | |
| TASK 25-54-12-000-003-A | Removal of the Sidewall Panels in the Forward Cargo Compartment |
| FOR [140DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | |
| FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-003-A | Open the FWD or Aft Cargo-Compartment Door with the Hand Pump |
| FOR [15DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | |
| TASK 25-55-12-000-003-A | Removal of the Sidewall Panels in the Aft Cargo Compartment - FR59/FR65 |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-003-A | Open the FWD or Aft Cargo-Compartment Door with the Hand Pump |
| FOR [15DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | |
| FOR [35DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | |
| TASK 25-55-12-000-003-A | Removal of the Sidewall Panels in the Aft Cargo Compartment - FR59/FR65 |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-003-A | Open the FWD or Aft Cargo-Compartment Door with the Hand Pump |
| FOR [3DW] (CONTROL UNIT, POTABLE WATERICE PROTECTION-) | |
| TASK 25-54-12-000-003-A | Removal of the Sidewall Panels in the Forward Cargo Compartment |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-003-A | Open the FWD or Aft Cargo-Compartment Door with the Hand Pump |
| FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-) | |
| TASK 25-54-12-000-003-A | Removal of the Sidewall Panels in the Forward Cargo Compartment |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-003-A | Open the FWD or Aft Cargo-Compartment Door with the Hand Pump |
Subtask 30-71-34-861-050-A Subtask 30-71-34-865-059-A
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 30-71-34-010-051-C ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WASTE WIP-DRAINMAST-FWD | 1DU | B06 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | POT/WASTE WIP-HEATER-LINE | 21DW | A03 |
| 2000VU | POT/WASTE WIP-HEATER-LINE | 1DW | A02 |
| 2000VU | POT/WASTE WIP-HEATER-CTL | 2DW | A01 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DRAINMAST-FWD | 1DU | B03 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | POT WIP-HEATER-LINE | 21DW | A03 |
| 2000VU | WASTE WIP-DRAINMAST-FWD | 1DU | B03 |
| 2000VU | WASTE WIP-HEATER-CTL | 9DU | B02 |
| 2000VU | WASTE WIP-HEATER-LINE | 8DU | B01 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | POT WIP-HEATER-LINE | 1DW | A02 |
| 2000VU | POT WIP-HEATER-CTL | 2DW | A01 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WASTE WIP-HEATER-CTL | 9DU | B05 |
| 2000VU | WASTE WIP-HEATER-LINE | 8DU | B04 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | POT/WASTE WIP-HEATER-CTL | 32DW | D02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | POT/WASTE WIP-HEATER-LINE | 51DW | D04 |
| 2001VU | POT/WASTE WIP-HEATER-LINE | 31DW | D03 |
| 2001VU | WASTE WIP-HEATER-LINE | 31DU | E04 |
| ** ON A/C ALL | |||
| 2001VU | WASTE WIP-DRAINMAST-AFT | 11DU | E01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | POT/WASTE WIP HEATER CTL | 32DW | D02 |
| 2001VU | WASTE WIP-HEATER-LINE | 22DU | E04 |
| 2001VU | WASTE WIP-HEATER-CTL | 10DU | E03 |
| 2001VU | WASTE WIP-DRAINMAST-MID | 21DU | E02 |
C. Get Access
(1) FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the FWD cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(b) Set the CARGO COMPT light switch 6LU to ON.
(c) Remove the sidewall panel 131MW.
(2) FOR [15DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the AFT cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(b) Set the CARGO COMPT light switch 8LU to ON.
(c) Remove the sidewall panel 162CW.
Subtask 30-71-34-010-051-E ** ON A/C NOT FOR ALL (1) FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the FWD cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(b) Set the CARGO COMPT light switch 6LU to ON.
(c) Remove the sidewall panel 131MW.
(2) FOR [15DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the AFT cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(b) Set the CARGO COMPT light switch 8LU to ON.
(c) Remove the sidewall panel 162CW.
C. Get Access
(1) FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) or (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) in position below the forward cargo-copartment door.
(c) Set the cargo-compartment light switch 6LU to ON.
(d) Remove the sidewall panel 131MW.
(2) FOR [15DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-), [35DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) or (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) in position below the aft cargo-copartment door.
(c) Set the cargo-compartment light switch 8LU to ON.
(d) Remove the sidewall panel 162CW.
Subtask 30-71-34-010-051-G ** ON A/C NOT FOR ALL (1) FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) or (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) in position below the forward cargo-copartment door.
(c) Set the cargo-compartment light switch 6LU to ON.
(d) Remove the sidewall panel 131MW.
(2) FOR [15DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-), [35DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) or (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) in position below the aft cargo-copartment door.
(c) Set the cargo-compartment light switch 8LU to ON.
(d) Remove the sidewall panel 162CW.
C. Get Access
(1) FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-), [140DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) in position at the forward cargo-compartment door.
(c) Set cargo-compartment light switch 6LU to ON.
(2) FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Remove sidewall panel 131MW (Ref. AMM TASK 25-54-12-000-003).
(3) FOR [140DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Remove sidewall panel 132KW (Ref. AMM TASK 25-54-12-000-003).
(4) FOR [15DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) in position at the aft cargo-compartment door.
(c) Set cargo-compartment light switch 8LU to ON.
(d) Remove sidewall panel 162CW (Ref. AMM TASK 25-55-12-000-003).
Subtask 30-71-34-010-051-N ** ON A/C NOT FOR ALL (1) FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-), [140DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) in position at the forward cargo-compartment door.
(c) Set cargo-compartment light switch 6LU to ON.
(2) FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Remove sidewall panel 131MW (Ref. AMM TASK 25-54-12-000-003).
(3) FOR [140DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Remove sidewall panel 132KW (Ref. AMM TASK 25-54-12-000-003).
(4) FOR [15DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) in position at the aft cargo-compartment door.
(c) Set cargo-compartment light switch 8LU to ON.
(d) Remove sidewall panel 162CW (Ref. AMM TASK 25-55-12-000-003).
C. Get Access
(1) FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) or (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(c) Set cargo-compartment light switch 6LU to ON.
(d) Remove sidewall panel 131MW (Ref. AMM TASK 25-54-12-000-003).
(2) FOR [15DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-), [35DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(c) Set cargo-compartment light switch 8LU to ON.
(d) Remove sidewall panel 162CW (Ref. AMM TASK 25-55-12-000-003).
(3) FOR [3DW] (CONTROL UNIT, POTABLE WATERICE PROTECTION-)
(a) Open the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(c) Set cargo-compartment light switch 6LU to ON.
(d) Remove sidewall panel 132JW (Ref. AMM TASK 25-54-12-000-003).
Subtask 30-71-34-010-051-R ** ON A/C NOT FOR ALL (1) FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) or (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(c) Set cargo-compartment light switch 6LU to ON.
(d) Remove sidewall panel 131MW (Ref. AMM TASK 25-54-12-000-003).
(2) FOR [15DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-), [35DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(c) Set cargo-compartment light switch 8LU to ON.
(d) Remove sidewall panel 162CW (Ref. AMM TASK 25-55-12-000-003).
(3) FOR [3DW] (CONTROL UNIT, POTABLE WATERICE PROTECTION-)
(a) Open the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(c) Set cargo-compartment light switch 6LU to ON.
(d) Remove sidewall panel 132JW (Ref. AMM TASK 25-54-12-000-003).
C. Get Access
(1) FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-), [140DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) or (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(c) Set cargo-compartment light switch 6LU to ON.
(2) FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Remove sidewall panel 131MW (Ref. AMM TASK 25-54-12-000-003).
(3) FOR [140DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Remove sidewall panel 132KW (Ref. AMM TASK 25-54-12-000-003).
(4) FOR [15DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-), [35DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) or (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(c) Set cargo-compartment light switch 8LU to ON.
(d) Remove sidewall panel 162CW (Ref. AMM TASK 25-55-12-000-003).
4. Procedure(1) FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-), [140DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) or (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(c) Set cargo-compartment light switch 6LU to ON.
(2) FOR [5DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Remove sidewall panel 131MW (Ref. AMM TASK 25-54-12-000-003).
(3) FOR [140DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Remove sidewall panel 132KW (Ref. AMM TASK 25-54-12-000-003).
(4) FOR [15DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-), [35DU] (CONTROL UNIT, WASTE WATER ICE PROTECTION-)
(a) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) or (Ref. AMM TASK 52-30-00-860-003).
(b) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(c) Set cargo-compartment light switch 8LU to ON.
(d) Remove sidewall panel 162CW (Ref. AMM TASK 25-55-12-000-003).
Subtask 30-71-34-020-051-A
A. Removal of a control unit
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the screws (5), the washers (4) and the brackets (3) which hold the control unit (2) in position.
(4) Remove the control unit (2) from its support (1).
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(1) Disconnect the electrical connector (6) from the control unit (2). (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the screws (5), the washers (4) and the brackets (3) which hold the control unit (2) in position.
(4) Remove the control unit (2) from its support (1).
Control Unit 103DW