Installation of Sensor
TASK 30-71-19-400-001-A
Installation of Sensor
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 30-71-19-860-050-A ** ON A/C NOT FOR ALL
Subtask 30-71-19-420-050-A ** ON A/C NOT FOR ALL
Subtask 30-71-19-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:31:55 UTC
Installation of Sensor
WARNING:
DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
- FLUSH IT AWAY WITH CLEAN WATER
- GET MEDICAL AID.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION:
USE ONLY THE SPECIFIED MATERIALS AND OBEY THE INSTRUCTIONS FROM THE MATERIAL MANUFACTURERS. OTHER MATERIALS CAN CAUSE DAMAGE TO THE SURFACE PROTECTION OF THE COMPONENTS AND THE RELATED AREA.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20 |
| No specific | AR | TIE WRAP(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.05RAB9) | Adhesive Film Tape-- Aluminium Foil - |
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 150 | AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT |
| 170 | AFT CAB U/FLOOR COMPT AFT BHD OF BULK |
| 162DW |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 25-55-12-000-001-A | Removal of the Aft Cargo-Compartment Partition at FR65 |
| TASK 25-55-12-400-001-A | Installation of the Aft Cargo-Compartment Partition at FR65 |
| TASK 30-71-00-710-002-A | Operational Test of the Waste-Water Ice-Protection Heater-Elements |
| TASK 52-30-00-860-006-A | Open the Bulk Cargo-Compartment Door |
| TASK 52-30-00-860-008-A | Close the Bulk Cargo-Compartment Door |
Subtask 30-71-19-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the bulk cargo-compartment door is open (Ref. AMM TASK 52-30-00-860-006).
(3) Make sure that cargo-compartment light switch 18LU is set to on.
(4) Make sure that rear-wall partition-panel 162DW is removed (Ref. AMM TASK 25-55-12-000-001).
Subtask 30-71-19-865-054-A ** ON A/C NOT FOR ALL (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the bulk cargo-compartment door is open (Ref. AMM TASK 52-30-00-860-006).
(3) Make sure that cargo-compartment light switch 18LU is set to on.
(4) Make sure that rear-wall partition-panel 162DW is removed (Ref. AMM TASK 25-55-12-000-001).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 30-71-19-140-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | POT/WASTE WIP-HEATER-CTL | 32DW | D02 |
| 2001VU | WASTE WIP-HEATER-LINE | 31DU | E04 |
C. Preparation for Installation
(2) Do an inspection of the component interfaces and the adjacent area.
4. ProcedureWARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
(1) Clean the waste water line with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) . (2) Do an inspection of the component interfaces and the adjacent area.
Subtask 30-71-19-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Temperature Sensor
(2) Tighten the screws (1). Make sure that the sensor assemblies (3) and (4) are correctly installed on the tank connection tube (5).
(3) Connect the electrical connections (2) with the ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20.
(5) Attach the electrical wires to the tank connecting tube (5) with TIE WRAP(S).
Subtask 30-71-19-865-057-A ** ON A/C NOT FOR ALL NOTE: The operational temperature of the temperature sensor:
- the sensor will come on at 6.0 deg. +1 -1 C (42.80 deg. +1.80 -1.80 F )
- and switch off at approximately 10.0 deg. C (50.00 deg. F ).
(1) Install the sensor assemblies (3) and (4) on the tank connecting tube (5). - the sensor will come on at 6.0 deg. +1 -1 C (42.80 deg. +1.80 -1.80 F )
- and switch off at approximately 10.0 deg. C (50.00 deg. F ).
(2) Tighten the screws (1). Make sure that the sensor assemblies (3) and (4) are correctly installed on the tank connection tube (5).
(3) Connect the electrical connections (2) with the ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20.
NOTE: You must connect the electrical connections as identified during the removal procedure.
(4) Install the insulation blanket (6) and attach it with Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) . Make sure that the electrical connections (2) are free of the insulation blanket (6). (5) Attach the electrical wires to the tank connecting tube (5) with TIE WRAP(S).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 30-71-19-710-050-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | POT/WASTE WIP-HEATER-CTL | 32DW | D02 |
| 2001VU | WASTE WIP-HEATER-LINE | 31DU | E04 |
Subtask 30-71-19-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install rear-wall partition-panel 162DW (Ref. AMM TASK 25-55-12-400-001).
(3) Set cargo-compartment light switch 18LU to off.
(4) Close the bulk cargo-compartment door (Ref. AMM TASK 52-30-00-860-008).
Subtask 30-71-19-862-050-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install rear-wall partition-panel 162DW (Ref. AMM TASK 25-55-12-400-001).
(3) Set cargo-compartment light switch 18LU to off.
(4) Close the bulk cargo-compartment door (Ref. AMM TASK 52-30-00-860-008).