Deactivation of the Waste-Water Drain Mast Heating-System
TASK 30-71-00-040-001-A
Deactivation of the Waste-Water Drain Mast Heating-System
1. Reason for the Job
MMEL 30-71-01A
WASTE WATER DRAIN MAST HEATING SYSTEM
MMEL 30-71-01B
WASTE WATER DRAIN MAST HEATING SYSTEM
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 30-71-00-861-055-A
Subtask 30-71-00-040-051-E
Subtask 30-71-00-860-054-A
[Rev.10 from 2021]
2026.04.01 00:31:39 UTC
Deactivation of the Waste-Water Drain Mast Heating-System
1. Reason for the Job
MMEL 30-71-01A
WASTE WATER DRAIN MAST HEATING SYSTEM
MMEL 30-71-01B
WASTE WATER DRAIN MAST HEATING SYSTEM
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | PLACARD |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 30-71-00-861-055-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 30-71-00-862-050-A (Ref. AMM TASK 24-41-00-861-002).
NOTE: Airbus recommends that you open the circuit breaker(s) related to the defective drain mast only.
DELETED
Subtask 30-71-00-865-072-A C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WASTE WIP-DRAINMAST-FWD | 1DU | B06 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DRAINMAST-FWD | 1DU | B03 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WASTE WIP-DRAINMAST-FWD | 1DU | B03 |
| ** ON A/C ALL | |||
| 2001VU | WASTE WIP-DRAINMAST-AFT | 11DU | E01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WASTE WIP-DRAINMAST-MID | 21DU | E02 |
Subtask 30-71-00-040-051-E
A. Deactivation Procedure
(1) Open the lavatory door.
(2) Close the manual shutoff valve of the related lavatory water supply. The shutoff valve is installed below the wash basin.
(3) Put a PLACARD on the related lavatory doors to show persons that the lavatories are not in use.
(4) Close and lock the lavatory doors.
(5) Close the shutoff valve of the related galley water supply.
(6) Put a PLACARD on the related galley water supply to tell persons not to operate the water faucet.
5. Close-up(1) Open the lavatory door.
(2) Close the manual shutoff valve of the related lavatory water supply. The shutoff valve is installed below the wash basin.
(3) Put a PLACARD on the related lavatory doors to show persons that the lavatories are not in use.
(4) Close and lock the lavatory doors.
(5) Close the shutoff valve of the related galley water supply.
(6) Put a PLACARD on the related galley water supply to tell persons not to operate the water faucet.
Subtask 30-71-00-860-054-A
A. Make an entry in the logbook.
Subtask 30-71-00-862-056-A
Potable Water Lavatory Shutoff Valve