Removal of the Wiper Motor Converter
TASK 30-45-51-000-001-A
Removal of the Wiper Motor Converter
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 30-45-51-865-050-A
Subtask 30-45-51-020-053-A
[Rev.10 from 2021]
2026.04.01 00:31:29 UTC
Removal of the Wiper Motor Converter
WARNING:
MAKE SURE THAT THE CIRCUIT BREAKERS RELATED TO THE WEATHER RADAR ARE OPENED, SAFETIED AND TAGGED.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 211 | COCKPIT |
| 212 | COCKPIT |
| 211LW, 811 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 25-13-41-000-002-A | Removal of the Sidewall Panels |
| TASK 30-45-52-000-002-A | Removal of the Wiper Arm |
Subtask 30-45-51-865-050-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 30-45-51-010-050-A Subtask 30-45-51-020-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 6DB1 (MOTOR CONVERTERWIPER, CAPT) | |||
| 49VU | ANTI ICE/RAIN/RPLNT/CAPT | 1DB1 | D01 |
| ** ON A/C ALL | |||
| 121VU | COM NAV/RADAR/1 | 5SQ1 | K13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/RADAR/2 | 5SQ2 | K14 |
| ** ON A/C ALL | |||
| 122VU | ANTI ICE/WIPER/CAPT | 4DB1 | X12 |
| FOR FIN: 6DB2 (MOTOR CONVERTERWIPER, F/O) | |||
| 121VU | COM NAV/RADAR/1 | 5SQ1 | K13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/RADAR/2 | 5SQ2 | K14 |
| ** ON A/C ALL | |||
| 122VU | ANTI ICE/F/O/WIPER | 4DB2 | W12 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | ANTI ICE/RAIN/RPLNT/F/O | 1DB2 | W11 |
C. Removal of the adjacent components
(1) Remove the wiper arm (6) (Ref. AMM TASK 30-45-52-000-002).
(2) In the cockpit, remove sidewall panel 211LW (1) (Ref. AMM TASK 25-13-41-000-002).
4. Procedure(1) Remove the wiper arm (6) (Ref. AMM TASK 30-45-52-000-002).
(2) In the cockpit, remove sidewall panel 211LW (1) (Ref. AMM TASK 25-13-41-000-002).
Subtask 30-45-51-020-053-A
A. Disconnection
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
Subtask 30-45-51-020-051-A CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(1) From the manhole, disconnect the electrical connector (5) from the motor converter (4). (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
B. Removal of the Motor Converter
(2) Remove the motor converter (4) from the support bracket (7).
(3) From the outer side of the cockpit, remove and discard the O-ring (8).
NOTE: Two persons are necessary to remove the motor converter (4).
(1) From the inner side of the cockpit, remove the screws (2) and the washers (3). (2) Remove the motor converter (4) from the support bracket (7).
(3) From the outer side of the cockpit, remove and discard the O-ring (8).
Wiper Motor Converter