W DOC AIRBUS | AMM A320F

Installation of the Window Heat Computer (WHC)


TASK 30-42-34-400-001-A
Installation of the Window Heat Computer (WHC)


ZONE: 121
ZONE: 122
FIN: 2DG1
FIN: 2DG2
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
121
AVIONICS COMPARTMENT
122
AVIONICS COMPARTMENT
811
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 30-42-00-710-001-A
Operational Test of the Windshield Anti-Icing and Defogging
3. Job Set-up
Subtask 30-42-34-860-050-A
A. Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position.
Subtask 30-42-34-010-051-A
B. Make sure that the access door 811 is open.
Subtask 30-42-34-865-051-A
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 2DG1 (WHC1)
122VUANTI ICE/WINDOWS/L4DG1X14
122VUANTI ICE/WHC/15DG1X13
123VUANTI ICE/L/WHSLD1DG1AF10
FOR FIN: 2DG2 (WHC2)
122VUANTI ICE/WINDOWS/R4DG2W14
122VUANTI ICE/WHC/25DG2W13
123VUANTI ICE/R/WHSLD1DG2AF03
4. Procedure
Subtask 30-42-34-420-050-A
A. Installation of the Window Heat Computer (WHC)
   (1) Install the WHC (3).
   (2) Install the screws (2) and washers (1). Tighten the screws (2).
   (3) Remove the blanking caps and connect the electrical connectors (4) and (5).
5. Close-up
Subtask 30-42-34-865-052-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 2DG1 (WHC1)
122VUANTI ICE/WINDOWS/L4DG1X14
123VUANTI ICE/L/WHSLD1DG1AF10
FOR FIN: 2DG2 (WHC2)
122VUANTI ICE/WINDOWS/R4DG2W14
123VUANTI ICE/R/WHSLD1DG2AF03
Subtask 30-42-34-860-052-A
B. Circuit Breaker(s) Configuration
   (1) After two seconds, remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s) that follow.
Subtask 30-42-34-865-053-A
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 2DG1 (WHC1)
122VUANTI ICE/WHC/15DG1X13
FOR FIN: 2DG2 (WHC2)
122VUANTI ICE/WHC/25DG2W13
Subtask 30-42-34-710-050-A
D. Do an operational test of the cockpit windshield anti-icing and defogging system (Ref. AMM TASK 30-42-00-710-001)
Subtask 30-42-34-410-050-A
E. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access door 811.
   (3) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.01 00:30:59 UTC