Installation of the Probe Heat Computer (PHC)
TASK 30-31-34-400-002-A
Installation of the Probe Heat Computer (PHC)
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 30-31-34-865-052-A
Subtask 30-31-34-010-051-A
Subtask 30-31-34-420-050-A
Subtask 30-31-34-710-050-A 5. Close-up
Subtask 30-31-34-410-050-A
[Rev.10 from 2021]
2026.04.01 00:30:51 UTC
Installation of the Probe Heat Computer (PHC)
WARNING:
MAKE SURE THAT CIRCUIT BREAKERS 2KS1 AND 2KS2 ARE CLOSED BEFORE YOU CLOSE PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3). IF YOU DO NOT OBEY THIS INSTRUCTION:
- THE PROBES WILL BECOME TOO HOT.
- THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121 | AVIONICS COMPARTMENT |
| 122 | AVIONICS COMPARTMENT |
| 811 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 30-31-00-710-001-A | Operational Test of the Probe Ice Protection |
Subtask 30-31-34-865-052-A
WARNING:
MAKE SURE THAT THE PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3) ARE OPEN BEFORE YOU OPEN THE PHC CIRCUIT BREAKERS 2DA1(2,3). IF YOU DO NOT OBEY THIS PRECAUTION, THE PROBES WILL BECOME TOO HOT. THIS CAN CAUSE INJURY TO MAINTENANCE PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 6DA1 (PHC1) | |||
| 49VU | ANTI ICE/PROBES/AOA/1 | 4DA1 | D04 |
| 49VU | ANTI ICE/PROBES/PHC/1 | 2DA1 | D03 |
| 49VU | ANTI ICE/PROBES/PITOT/1 | 3DA1 | D02 |
| 122VU | ANTI ICE/PROBES/1/STATIC | 5DA1 | Z13 |
| 122VU | ANTI ICE/PROBES/1/TAT | 1DA1 | Z12 |
| FOR FIN: 6DA2 (PHC2) | |||
| 122VU | ANTI ICE/PROBES/2/TAT | 1DA2 | Y15 |
| 122VU | ANTI ICE/PROBES/2/PITOT | 3DA2 | Y14 |
| 122VU | ANTI ICE/PROBES/2/AOA | 4DA2 | Y13 |
| 122VU | ANTI ICE/PROBES/PHC/2 | 2DA2 | Y12 |
| 122VU | ANTI ICE/PROBES/2/STATIC | 5DA2 | Y11 |
| FOR FIN: 6DA3 (PHC3) | |||
| 122VU | ANTI ICE/PROBES/PHC/3 | 2DA3 | Y16 |
| 122VU | ANTI ICE/PROBES/3/PITOT | 3DA3 | Z16 |
| 122VU | ANTI ICE/PROBES/3/AOA | 4DA3 | Z15 |
| 122VU | ANTI ICE/PROBES/3/STATIC | 5DA3 | Z14 |
B. Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position.
(1) Make sure that the access door 811 is open.
4. Procedure(1) Make sure that the access door 811 is open.
Subtask 30-31-34-420-050-A
A. Installation of the PHC
(1) Install the PHC (3).
(2) Install the screws (1) and the washers (2).
(3) Tighten the screws (1).
(4) Remove the CAP-BLANKING from each electrical connector and receptacle.
Subtask 30-31-34-865-053-A (1) Install the PHC (3).
(2) Install the screws (1) and the washers (2).
(3) Tighten the screws (1).
(4) Remove the CAP-BLANKING from each electrical connector and receptacle.
CAUTION:
DO NOT TWIST OR BEND THE ELECTRICAL HARNESS WHEN YOU DISCONNECT/CONNECT THE ELECTRICAL CONNECTOR. IF YOU DO, YOU CAN CAUSE DAMAGE TO THE HARNESS AND THUS CAUSE ELECTRICAL CIRCUIT DEFECTS.
(5) Turn the position of the backshell in relation to the PHC according to the ESPM 20-33-45 and connect the electrical connector (4). NOTE: Obey the rules in the ESPM 20-33-11 to prevent the electrical harness stress, twist or wrong bend radius.
WARNING:
CLOSE THE PHC CIRCUIT BREAKERS 2DA1(2,3) BEFORE YOU CLOSE THE PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3). IF YOU DO NOT OBEY THIS SEQUENCE, THE PROBES WILL BECOME TOO HOT. THIS CAN CAUSE INJURY TO MAINTENANCE PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
B. Remove the safety clips and tags and close these circuit breakers in this sequence:| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 6DA1 (PHC1) | |||
| 49VU | ANTI ICE/PROBES/PHC/1 | 2DA1 | D03 |
| 122VU | ANTI ICE/PROBES/1/TAT | 1DA1 | Z12 |
| 49VU | ANTI ICE/PROBES/PITOT/1 | 3DA1 | D02 |
| 49VU | ANTI ICE/PROBES/AOA/1 | 4DA1 | D04 |
| 122VU | ANTI ICE/PROBES/1/STATIC | 5DA1 | Z13 |
| FOR FIN: 6DA2 (PHC2) | |||
| 122VU | ANTI ICE/PROBES/PHC/2 | 2DA2 | Y12 |
| 122VU | ANTI ICE/PROBES/2/TAT | 1DA2 | Y15 |
| 122VU | ANTI ICE/PROBES/2/PITOT | 3DA2 | Y14 |
| 122VU | ANTI ICE/PROBES/2/AOA | 4DA2 | Y13 |
| 122VU | ANTI ICE/PROBES/2/STATIC | 5DA2 | Y11 |
| FOR FIN: 6DA3 (PHC3) | |||
| 122VU | ANTI ICE/PROBES/PHC/3 | 2DA3 | Y16 |
| 122VU | ANTI ICE/PROBES/3/PITOT | 3DA3 | Z16 |
| 122VU | ANTI ICE/PROBES/3/AOA | 4DA3 | Z15 |
| 122VU | ANTI ICE/PROBES/3/STATIC | 5DA3 | Z14 |
Subtask 30-31-34-410-050-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 811.
(3) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 811.
(3) Remove the access platform(s).
PHC Backshell Connector