Functional Test of the Heating of the Angle of Attack Sensor
TASK 30-31-00-710-802-A
Functional Test of the Heating of the Angle of Attack Sensor
This task gives a method to measure the current in the AOA sensor heating-element.
The recorded value is necessary for:
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 30-31-00-861-067-A ** ON A/C NOT FOR ALL Subtask 30-31-00-865-149-A
Subtask 30-31-00-710-063-A ** ON A/C NOT FOR ALL 5. Close-up
Subtask 30-31-00-862-062-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:20:07 UTC
Functional Test of the Heating of the Angle of Attack Sensor
WARNING:
MAKE SURE THAT CIRCUIT BREAKERS 2KS1 AND 2KS2 ARE CLOSED BEFORE YOU OPEN PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3). IF YOU DO NOT OBEY THIS INSTRUCTION:
- THE PROBES WILL BECOME TOO HOT.
- THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
WARNING:
BEFORE YOU OPEN PHC CIRCUIT BREAKERS 2DA1(2,3), OPEN PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3). IF YOU DO NOT OBEY THIS SEQUENCE:
- THE PROBES WILL BECOME TOO HOT.
- THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
1. Reason for the JobThis task gives a method to measure the current in the AOA sensor heating-element.
The recorded value is necessary for:
- The trouble shooting procedures, or
- The inspection SB 34-1415.
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)-LOAD CAPACITY 500 KG MINI |
| No specific | 1 | MULTIMETER 115 VAC, 10 A - TRMS |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| 97D34103000000 | 1 | AOA SENSOR TOOL |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 127 | REAR AVIONIC COMPARTMENT |
| 231 | FWD PASSENGER COMPARTMENT |
| 232 | FWD PASSENGER COMPARTMENT |
| 811 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 30-31-00-710-001-A | Operational Test of the Probe Ice Protection |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
| TSM 30-31-00-810-808 | Failure of the Angle of Attack Sensor (PHC 1) |
| TSM 30-31-00-810-819 | Failure of the Angle of Attack Sensor (PHC 2) |
| TSM 30-31-00-810-830 | Failure of the Angle of Attack Sensor (PHC 3) |
Subtask 30-31-00-861-067-A ** ON A/C NOT FOR ALL Subtask 30-31-00-865-149-A
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 30-31-00-860-088-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 3FP1 (SENSORANGLE OF ATTACK, 1) | |||
| 49VU | ANTI ICE/PROBES/AOA/1 | 4DA1 | D04 |
| 49VU | ANTI ICE/PROBES/PHC/1 | 2DA1 | D03 |
| 49VU | ANTI ICE/PROBES/PITOT/1 | 3DA1 | D02 |
| 49VU | NAV PROBES/ADIRU 1/AND AOA 1/26VAC | 5FP1 | F07 |
| 49VU | NAV PROBES/ADIRU1/115VAC | 4FP1 | F06 |
| 121VU | ADIRS/ADIRU/3PWR/SWTG | 9FP | N09 |
| 122VU | ANTI ICE/PROBES/1/STATIC | 5DA1 | Z13 |
| 122VU | ANTI ICE/PROBES/1/TAT | 1DA1 | Z12 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 3FP2 (SENSORANGLE OF ATTACK, 2) | |||
| 121VU | ADIRS/ADIRU/2PWR/SHED | 10FP | N10 |
| ** ON A/C ALL | |||
| 121VU | ADIRS/ADIRU/2/26VAC AND AOA | 5FP2 | N08 |
| 121VU | ADIRS/ADIRU/2/115VAC | 4FP2 | N06 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ADIRS/2PWR/SHED &/AOA2 MON | 10FP | N10 |
| ** ON A/C ALL | |||
| 122VU | ANTI ICE/PROBES/2/TAT | 1DA2 | Y15 |
| 122VU | ANTI ICE/PROBES/2/PITOT | 3DA2 | Y14 |
| 122VU | ANTI ICE/PROBES/2/AOA | 4DA2 | Y13 |
| 122VU | ANTI ICE/PROBES/PHC/2 | 2DA2 | Y12 |
| 122VU | ANTI ICE/PROBES/2/STATIC | 5DA2 | Y11 |
| FOR FIN: 3FP3 (SENSORANGLE OF ATTACK, 3) | |||
| 121VU | ADIRS/ADIRU/3PWR/SWTG | 9FP | N09 |
| 121VU | ADIRS/ADIRU/3/26VAC AND AOA | 5FP3 | N07 |
| 121VU | ADIRS/ADIRU/3/115VAC | 4FP3 | N05 |
| 122VU | ANTI ICE/PROBES/PHC/3 | 2DA3 | Y16 |
| 122VU | ANTI ICE/PROBES/3/PITOT | 3DA3 | Z16 |
| 122VU | ANTI ICE/PROBES/3/AOA | 4DA3 | Z15 |
| 122VU | ANTI ICE/PROBES/3/STATIC | 5DA3 | Z14 |
C. Aircraft Maintenance Configuration
(1) On the ANTI ICE section of panel 25VU:
Subtask 30-31-00-941-068-A (1) On the ANTI ICE section of panel 25VU:
- Make sure that the PROBE/WINDOW HEAT pushbutton switch is released (the ON legend is off).
- Make sure that the AIR DATA selector switch is in the NORM position.
D. Safety Precautions
(1) Put a WARNING NOTICE(S) in position to tell persons not to use these controls:
(a) Put an ACCESS PLATFORM 3M (10 FT)-LOAD CAPACITY 500 KG MINI in position:
1 FOR [3FP1] (SENSOR-ANGLE OF ATTACK, 1)
At zone 231
2 FOR [3FP2] (SENSOR-ANGLE OF ATTACK, 2)
At zone 232
3 FOR [3FP3] (SENSOR-ANGLE OF ATTACK, 3)
At zone 127.
(b) Remove the related protective cover.
Subtask 30-31-00-010-052-A (1) Put a WARNING NOTICE(S) in position to tell persons not to use these controls:
- PROBE/WINDOW HEAT pushbutton switch
- AIR DATA selector switch.
(a) Put an ACCESS PLATFORM 3M (10 FT)-LOAD CAPACITY 500 KG MINI in position:
1 FOR [3FP1] (SENSOR-ANGLE OF ATTACK, 1)
At zone 231
2 FOR [3FP2] (SENSOR-ANGLE OF ATTACK, 2)
At zone 232
3 FOR [3FP3] (SENSOR-ANGLE OF ATTACK, 3)
At zone 127.
(b) Remove the related protective cover.
E. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the access door 811.
(2) Open the access door 811 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the access door 811.
(2) Open the access door 811 (Ref. AMM TASK 52-41-00-010-002).
CAUTION:
REMOVE THE PROTECTIVE COVERS FROM THE PROBES BEFORE YOU DO THE TEST.
Subtask 30-31-00-720-052-A ** ON A/C NOT FOR ALL A. Functional Test of the Heating of the Angle of Attack Sensor
(1) Disconnect the connector from the PHC of the related angle of attack sensor:
(a) FOR [3FP1] (SENSOR-ANGLE OF ATTACK, 1)
PHC1 (6DA1)
(b) FOR [3FP2] (SENSOR-ANGLE OF ATTACK, 2)
PHC2 (6DA2)
(c) FOR [3FP3] (SENSOR-ANGLE OF ATTACK, 3)
PHC3 (6DA3).
(2) Remove the blanking cap from the 97D34103000000 AOA SENSOR TOOL.
(3) Make sure that the switch of the 97D34103000000 AOA SENSOR TOOL is in the OFF position.
(4) Connect the disconnected cable to the 97D34103000000 AOA SENSOR TOOL.
(5) Connect a MULTIMETER 115 VAC, 10 A - TRMS, to the 97D34103000000 AOA SENSOR TOOL.
(6) Close the circuit breaker related to the angle of attack sensor:
(a) FOR [3FP1] (SENSOR-ANGLE OF ATTACK, 1)
Circuit breaker 4DA1
(b) FOR [3FP2] (SENSOR-ANGLE OF ATTACK, 2)
Circuit breaker 4DA2
(c) FOR [3FP3] (SENSOR-ANGLE OF ATTACK, 3)
Circuit breaker 4DA3.
(7) Do a check of the maximum current (Imax) at start-up:
(a) Set the switch of the 97D34103000000 AOA SENSOR TOOL to ON.
(b) With the MULTIMETER 115 VAC, 10 A - TRMS, do a check of the value of the maximum current (Imax) at start-up (in 30 seconds or less).
(9) Open the circuit breaker related to the AOA tested:
(a) FOR [3FP1] (SENSOR-ANGLE OF ATTACK, 1)
Circuit breaker 4DA1
(b) FOR [3FP2] (SENSOR-ANGLE OF ATTACK, 2)
Circuit breaker 4DA2
(c) FOR [3FP3] (SENSOR-ANGLE OF ATTACK, 3)
Circuit breaker 4DA3.
(10) Disconnect the MULTIMETER 115 VAC, 10 A - TRMS, from the 97D34103000000 AOA SENSOR TOOL.
(11) Disconnect the cable from the 97D34103000000 AOA SENSOR TOOL.
(12) Put the blanking caps on the 97D34103000000 AOA SENSOR TOOL.
(13) Connect the disconnected cable to the related PHC.
Subtask 30-31-00-010-053-A Subtask 30-31-00-942-062-A ** ON A/C NOT FOR ALL (1) Disconnect the connector from the PHC of the related angle of attack sensor:
(a) FOR [3FP1] (SENSOR-ANGLE OF ATTACK, 1)
PHC1 (6DA1)
(b) FOR [3FP2] (SENSOR-ANGLE OF ATTACK, 2)
PHC2 (6DA2)
(c) FOR [3FP3] (SENSOR-ANGLE OF ATTACK, 3)
PHC3 (6DA3).
(2) Remove the blanking cap from the 97D34103000000 AOA SENSOR TOOL.
(3) Make sure that the switch of the 97D34103000000 AOA SENSOR TOOL is in the OFF position.
(4) Connect the disconnected cable to the 97D34103000000 AOA SENSOR TOOL.
(5) Connect a MULTIMETER 115 VAC, 10 A - TRMS, to the 97D34103000000 AOA SENSOR TOOL.
(6) Close the circuit breaker related to the angle of attack sensor:
(a) FOR [3FP1] (SENSOR-ANGLE OF ATTACK, 1)
Circuit breaker 4DA1
(b) FOR [3FP2] (SENSOR-ANGLE OF ATTACK, 2)
Circuit breaker 4DA2
(c) FOR [3FP3] (SENSOR-ANGLE OF ATTACK, 3)
Circuit breaker 4DA3.
(7) Do a check of the maximum current (Imax) at start-up:
(a) Set the switch of the 97D34103000000 AOA SENSOR TOOL to ON.
(b) With the MULTIMETER 115 VAC, 10 A - TRMS, do a check of the value of the maximum current (Imax) at start-up (in 30 seconds or less).
NOTE: The maximum current (Imax) in the heater of the AOA sensor can be measured only at start-up. After the start-up, the current decreases to its nominal consumption.
(c) Record the result. NOTE: The measured current must be more than 1.3A.
If the measured current is less than 1.3A, refer either to:
(d) Put the switch of the 97D34103000000 AOA SENSOR TOOL back to the OFF position. If the measured current is less than 1.3A, refer either to:
- The trouble shooting procedures TSM 30-31-00-810-808 or TSM 30-31-00-810-819, or TSM 30-31-00-810-830 for corrective action, or to
- The flow chart of the inspection SB 34-1415.
CAUTION:
AFTER YOU MEASURE THE CURRENT OF A SENSOR, LET THE SENSOR BECOME COOL (15 MIN) BEFORE YOU MEASURE THE CURRENT AGAIN.
IF YOU DO NOT OBEY THIS PRECAUTION, YOU CAN CAUSE DAMAGE TO THE SENSOR.
(8) You must do the step (7) above two more times because the ageing of the angle of attack sensor can modify the result. (9) Open the circuit breaker related to the AOA tested:
(a) FOR [3FP1] (SENSOR-ANGLE OF ATTACK, 1)
Circuit breaker 4DA1
(b) FOR [3FP2] (SENSOR-ANGLE OF ATTACK, 2)
Circuit breaker 4DA2
(c) FOR [3FP3] (SENSOR-ANGLE OF ATTACK, 3)
Circuit breaker 4DA3.
(10) Disconnect the MULTIMETER 115 VAC, 10 A - TRMS, from the 97D34103000000 AOA SENSOR TOOL.
(11) Disconnect the cable from the 97D34103000000 AOA SENSOR TOOL.
(12) Put the blanking caps on the 97D34103000000 AOA SENSOR TOOL.
(13) Connect the disconnected cable to the related PHC.
C. Put the aircraft back to its initial configuration
(1) Remove the WARNING NOTICE(S).
Subtask 30-31-00-865-150-A (1) Remove the WARNING NOTICE(S).
WARNING:
CLOSE THE PHC CIRCUIT BREAKERS 2DA1(2,3) BEFORE YOU CLOSE THE PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3). IF YOU DO NOT OBEY THIS SEQUENCE, THE PROBES WILL BECOME TOO HOT. THIS CAN CAUSE INJURY TO MAINTENANCE PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
WARNING:
MAKE SURE THAT CIRCUIT BREAKERS 2KS1 AND 2KS2 ARE CLOSED BEFORE YOU CLOSE PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3). IF YOU DO NOT OBEY THIS INSTRUCTION:
- THE PROBES WILL BECOME TOO HOT.
- THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 3FP1 (SENSORANGLE OF ATTACK, 1) | |||
| 49VU | ANTI ICE/PROBES/AOA/1 | 4DA1 | D04 |
| 49VU | ANTI ICE/PROBES/PHC/1 | 2DA1 | D03 |
| 49VU | ANTI ICE/PROBES/PITOT/1 | 3DA1 | D02 |
| 49VU | NAV PROBES/ADIRU 1/AND AOA 1/26VAC | 5FP1 | F07 |
| 49VU | NAV PROBES/ADIRU1/115VAC | 4FP1 | F06 |
| 121VU | ADIRS/ADIRU/3PWR/SWTG | 9FP | N09 |
| 122VU | ANTI ICE/PROBES/1/STATIC | 5DA1 | Z13 |
| 122VU | ANTI ICE/PROBES/1/TAT | 1DA1 | Z12 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 3FP2 (SENSORANGLE OF ATTACK, 2) | |||
| 121VU | ADIRS/ADIRU/2PWR/SHED | 10FP | N10 |
| ** ON A/C ALL | |||
| 121VU | ADIRS/ADIRU/2/26VAC AND AOA | 5FP2 | N08 |
| 121VU | ADIRS/ADIRU/2/115VAC | 4FP2 | N06 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ADIRS/2PWR/SHED &/AOA2 MON | 10FP | N10 |
| ** ON A/C ALL | |||
| 122VU | ANTI ICE/PROBES/2/TAT | 1DA2 | Y15 |
| 122VU | ANTI ICE/PROBES/2/PITOT | 3DA2 | Y14 |
| 122VU | ANTI ICE/PROBES/2/AOA | 4DA2 | Y13 |
| 122VU | ANTI ICE/PROBES/PHC/2 | 2DA2 | Y12 |
| 122VU | ANTI ICE/PROBES/2/STATIC | 5DA2 | Y11 |
| FOR FIN: 3FP3 (SENSORANGLE OF ATTACK, 3) | |||
| 121VU | ADIRS/ADIRU/3PWR/SWTG | 9FP | N09 |
| 121VU | ADIRS/ADIRU/3/26VAC AND AOA | 5FP3 | N07 |
| 121VU | ADIRS/ADIRU/3/115VAC | 4FP3 | N05 |
| 122VU | ANTI ICE/PROBES/PHC/3 | 2DA3 | Y16 |
| 122VU | ANTI ICE/PROBES/3/PITOT | 3DA3 | Z16 |
| 122VU | ANTI ICE/PROBES/3/AOA | 4DA3 | Z15 |
| 122VU | ANTI ICE/PROBES/3/STATIC | 5DA3 | Z14 |
Subtask 30-31-00-862-062-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(3) Remove the access platform(s).
(4) Make sure that the work area is clean and clear of tools and other items.
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
CAUTION:
DO NOT TOUCH THE AOA VANE IMMEDIATELY AFTER POWER-OFF BECAUSE IT IS VERY HOT AND CAN BURN YOU. LET THE TEMPERATURE OF THE AOA VANE DECREASE FOR A FEW MINUTES BEFORE YOU TOUCH IT.
(2) If necessary, install the protective cover on the related angle of attack sensor. (3) Remove the access platform(s).
(4) Make sure that the work area is clean and clear of tools and other items.
AOA Sensor Tool Connection