Functional Test of the Heating of the Angle of Attack Sensor


TASK 30-31-00-710-802-A
Functional Test of the Heating of the Angle of Attack Sensor


WARNING: MAKE SURE THAT CIRCUIT BREAKERS 2KS1 AND 2KS2 ARE CLOSED BEFORE YOU OPEN PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3). IF YOU DO NOT OBEY THIS INSTRUCTION: - THE PROBES WILL BECOME TOO HOT. - THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
WARNING: BEFORE YOU OPEN PHC CIRCUIT BREAKERS 2DA1(2,3), OPEN PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3). IF YOU DO NOT OBEY THIS SEQUENCE: - THE PROBES WILL BECOME TOO HOT. - THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
ZONE: 120
ZONE: 127
ZONE: 231
ZONE: 232
1. Reason for the Job
This task gives a method to measure the current in the AOA sensor heating-element.
The recorded value is necessary for:
  • The trouble shooting procedures, or
  • The inspection SB 34-1415.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
1
ACCESS PLATFORM 3M (10 FT)-LOAD CAPACITY 500 KG MINI
No specific
1
MULTIMETER 115 VAC, 10 A - TRMS
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
97D34103000000
1
AOA SENSOR TOOL
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
120
AVIONICS COMPARTMENT
127
REAR AVIONIC COMPARTMENT
231
FWD PASSENGER COMPARTMENT
232
FWD PASSENGER COMPARTMENT
811
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 30-31-00-710-001-A
Operational Test of the Probe Ice Protection
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
TSM 30-31-00-810-808
Failure of the Angle of Attack Sensor (PHC 1)
TSM 30-31-00-810-819
Failure of the Angle of Attack Sensor (PHC 2)
TSM 30-31-00-810-830
Failure of the Angle of Attack Sensor (PHC 3)
3. Job Set-up
Subtask 30-31-00-861-067-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 30-31-00-865-149-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 3FP1 (SENSORANGLE OF ATTACK, 1)
49VUANTI ICE/PROBES/AOA/14DA1D04
49VUANTI ICE/PROBES/PHC/12DA1D03
49VUANTI ICE/PROBES/PITOT/13DA1D02
49VUNAV PROBES/ADIRU 1/AND AOA 1/26VAC5FP1F07
49VUNAV PROBES/ADIRU1/115VAC4FP1F06
121VUADIRS/ADIRU/3PWR/SWTG9FPN09
122VUANTI ICE/PROBES/1/STATIC5DA1Z13
122VUANTI ICE/PROBES/1/TAT1DA1Z12
** ON A/C NOT FOR ALL
FOR FIN: 3FP2 (SENSORANGLE OF ATTACK, 2)
121VUADIRS/ADIRU/2PWR/SHED10FPN10
** ON A/C ALL
121VUADIRS/ADIRU/2/26VAC AND AOA5FP2N08
121VUADIRS/ADIRU/2/115VAC4FP2N06
** ON A/C NOT FOR ALL
121VUADIRS/2PWR/SHED &/AOA2 MON10FPN10
** ON A/C ALL
122VUANTI ICE/PROBES/2/TAT1DA2Y15
122VUANTI ICE/PROBES/2/PITOT3DA2Y14
122VUANTI ICE/PROBES/2/AOA4DA2Y13
122VUANTI ICE/PROBES/PHC/22DA2Y12
122VUANTI ICE/PROBES/2/STATIC5DA2Y11
FOR FIN: 3FP3 (SENSORANGLE OF ATTACK, 3)
121VUADIRS/ADIRU/3PWR/SWTG9FPN09
121VUADIRS/ADIRU/3/26VAC AND AOA5FP3N07
121VUADIRS/ADIRU/3/115VAC4FP3N05
122VUANTI ICE/PROBES/PHC/32DA3Y16
122VUANTI ICE/PROBES/3/PITOT3DA3Z16
122VUANTI ICE/PROBES/3/AOA4DA3Z15
122VUANTI ICE/PROBES/3/STATIC5DA3Z14
Subtask 30-31-00-860-088-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) On the ANTI ICE section of panel 25VU:
  • Make sure that the PROBE/WINDOW HEAT pushbutton switch is released (the ON legend is off).
   (2) On the center pedestal, on the SWITCHING panel 8VU:
  • Make sure that the AIR DATA selector switch is in the NORM position.
Subtask 30-31-00-941-068-A
D. Safety Precautions
   (1) Put a WARNING NOTICE(S) in position to tell persons not to use these controls:
  • PROBE/WINDOW HEAT pushbutton switch
  • AIR DATA selector switch.
   (2) Remove the protective cover from the related angle of attack sensor as follows:
     (a) Put an ACCESS PLATFORM 3M (10 FT)-LOAD CAPACITY 500 KG MINI in position:
       1 FOR [3FP1] (SENSOR-ANGLE OF ATTACK, 1)
At zone 231
       2 FOR [3FP2] (SENSOR-ANGLE OF ATTACK, 2)
At zone 232
       3 FOR [3FP3] (SENSOR-ANGLE OF ATTACK, 3)
At zone 127.
     (b) Remove the related protective cover.
Subtask 30-31-00-010-052-A
E. Get Access
   (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the access door 811.
   (2) Open the access door 811 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure
CAUTION: REMOVE THE PROTECTIVE COVERS FROM THE PROBES BEFORE YOU DO THE TEST.
Subtask 30-31-00-720-052-A ** ON A/C NOT FOR ALL
A. Functional Test of the Heating of the Angle of Attack Sensor
   (1) Disconnect the connector from the PHC of the related angle of attack sensor:
     (a) FOR [3FP1] (SENSOR-ANGLE OF ATTACK, 1)
PHC1 (6DA1)
     (b) FOR [3FP2] (SENSOR-ANGLE OF ATTACK, 2)
PHC2 (6DA2)
     (c) FOR [3FP3] (SENSOR-ANGLE OF ATTACK, 3)
PHC3 (6DA3).
   (2) Remove the blanking cap from the 97D34103000000 AOA SENSOR TOOL.
   (3) Make sure that the switch of the 97D34103000000 AOA SENSOR TOOL is in the OFF position.
   (4) Connect the disconnected cable to the 97D34103000000 AOA SENSOR TOOL.
   (5) Connect a MULTIMETER 115 VAC, 10 A - TRMS, to the 97D34103000000 AOA SENSOR TOOL.
   (6) Close the circuit breaker related to the angle of attack sensor:
     (a) FOR [3FP1] (SENSOR-ANGLE OF ATTACK, 1)
Circuit breaker 4DA1
     (b) FOR [3FP2] (SENSOR-ANGLE OF ATTACK, 2)
Circuit breaker 4DA2
     (c) FOR [3FP3] (SENSOR-ANGLE OF ATTACK, 3)
Circuit breaker 4DA3.
   (7) Do a check of the maximum current (Imax) at start-up:
     (a) Set the switch of the 97D34103000000 AOA SENSOR TOOL to ON.
     (b) With the MULTIMETER 115 VAC, 10 A - TRMS, do a check of the value of the maximum current (Imax) at start-up (in 30 seconds or less).
NOTE: The maximum current (Imax) in the heater of the AOA sensor can be measured only at start-up. After the start-up, the current decreases to its nominal consumption.
     (c) Record the result.
NOTE: The measured current must be more than 1.3A.
If the measured current is less than 1.3A, refer either to:
     (d) Put the switch of the 97D34103000000 AOA SENSOR TOOL back to the OFF position.
CAUTION: AFTER YOU MEASURE THE CURRENT OF A SENSOR, LET THE SENSOR BECOME COOL (15 MIN) BEFORE YOU MEASURE THE CURRENT AGAIN. IF YOU DO NOT OBEY THIS PRECAUTION, YOU CAN CAUSE DAMAGE TO THE SENSOR.
   (8) You must do the step (7) above two more times because the ageing of the angle of attack sensor can modify the result.
   (9) Open the circuit breaker related to the AOA tested:
     (a) FOR [3FP1] (SENSOR-ANGLE OF ATTACK, 1)
Circuit breaker 4DA1
     (b) FOR [3FP2] (SENSOR-ANGLE OF ATTACK, 2)
Circuit breaker 4DA2
     (c) FOR [3FP3] (SENSOR-ANGLE OF ATTACK, 3)
Circuit breaker 4DA3.
   (10) Disconnect the MULTIMETER 115 VAC, 10 A - TRMS, from the 97D34103000000 AOA SENSOR TOOL.
   (11) Disconnect the cable from the 97D34103000000 AOA SENSOR TOOL.
   (12) Put the blanking caps on the 97D34103000000 AOA SENSOR TOOL.
   (13) Connect the disconnected cable to the related PHC.
Subtask 30-31-00-010-053-A
B. Close Access
   (1) Close the access door 811 (Ref. AMM TASK 52-41-00-410-002).
Subtask 30-31-00-942-062-A ** ON A/C NOT FOR ALL
C. Put the aircraft back to its initial configuration
   (1) Remove the WARNING NOTICE(S).
Subtask 30-31-00-865-150-A
WARNING: CLOSE THE PHC CIRCUIT BREAKERS 2DA1(2,3) BEFORE YOU CLOSE THE PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3). IF YOU DO NOT OBEY THIS SEQUENCE, THE PROBES WILL BECOME TOO HOT. THIS CAN CAUSE INJURY TO MAINTENANCE PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
WARNING: MAKE SURE THAT CIRCUIT BREAKERS 2KS1 AND 2KS2 ARE CLOSED BEFORE YOU CLOSE PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3). IF YOU DO NOT OBEY THIS INSTRUCTION: - THE PROBES WILL BECOME TOO HOT. - THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 3FP1 (SENSORANGLE OF ATTACK, 1)
49VUANTI ICE/PROBES/AOA/14DA1D04
49VUANTI ICE/PROBES/PHC/12DA1D03
49VUANTI ICE/PROBES/PITOT/13DA1D02
49VUNAV PROBES/ADIRU 1/AND AOA 1/26VAC5FP1F07
49VUNAV PROBES/ADIRU1/115VAC4FP1F06
121VUADIRS/ADIRU/3PWR/SWTG9FPN09
122VUANTI ICE/PROBES/1/STATIC5DA1Z13
122VUANTI ICE/PROBES/1/TAT1DA1Z12
** ON A/C NOT FOR ALL
FOR FIN: 3FP2 (SENSORANGLE OF ATTACK, 2)
121VUADIRS/ADIRU/2PWR/SHED10FPN10
** ON A/C ALL
121VUADIRS/ADIRU/2/26VAC AND AOA5FP2N08
121VUADIRS/ADIRU/2/115VAC4FP2N06
** ON A/C NOT FOR ALL
121VUADIRS/2PWR/SHED &/AOA2 MON10FPN10
** ON A/C ALL
122VUANTI ICE/PROBES/2/TAT1DA2Y15
122VUANTI ICE/PROBES/2/PITOT3DA2Y14
122VUANTI ICE/PROBES/2/AOA4DA2Y13
122VUANTI ICE/PROBES/PHC/22DA2Y12
122VUANTI ICE/PROBES/2/STATIC5DA2Y11
FOR FIN: 3FP3 (SENSORANGLE OF ATTACK, 3)
121VUADIRS/ADIRU/3PWR/SWTG9FPN09
121VUADIRS/ADIRU/3/26VAC AND AOA5FP3N07
121VUADIRS/ADIRU/3/115VAC4FP3N05
122VUANTI ICE/PROBES/PHC/32DA3Y16
122VUANTI ICE/PROBES/3/PITOT3DA3Z16
122VUANTI ICE/PROBES/3/AOA4DA3Z15
122VUANTI ICE/PROBES/3/STATIC5DA3Z14
Subtask 30-31-00-710-063-A ** ON A/C NOT FOR ALL
E. Do the Operational Test of the Probe Ice Protection (Ref. AMM TASK 30-31-00-710-001).
5. Close-up
Subtask 30-31-00-862-062-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
CAUTION: DO NOT TOUCH THE AOA VANE IMMEDIATELY AFTER POWER-OFF BECAUSE IT IS VERY HOT AND CAN BURN YOU. LET THE TEMPERATURE OF THE AOA VANE DECREASE FOR A FEW MINUTES BEFORE YOU TOUCH IT.
   (2) If necessary, install the protective cover on the related angle of attack sensor.
   (3) Remove the access platform(s).
   (4) Make sure that the work area is clean and clear of tools and other items.