Installation of the FWD Air-Intake Anti-Ice Valve Ventilation Lines
TASK 30-21-51-400-807-A
Installation of the FWD Air-Intake Anti-Ice Valve Ventilation Lines
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 30-21-51-861-067-A Subtask 30-21-51-941-073-A
Subtask 30-21-51-420-063-A
Subtask 30-21-51-410-087-A
[Rev.10 from 2021]
2026.04.02 06:20:06 UTC
Installation of the FWD Air-Intake Anti-Ice Valve Ventilation Lines
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 36-11-00-710-803-A | Operational Test of the Bleed Air System |
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-803-A | Closing of the Fan Cowl Doors |
| TASK 78-30-00-040-807-A | Deactivation of the Thrust Reverser System for Nacelle Maintenance (ICU) |
| TASK 78-30-00-440-807-A | Reactivation of the Thrust Reverser System after Nacelle Maintenance (ICU) |
| TASK 78-36-00-010-806-A | Opening of the Thrust Reverser Cowl Doors |
| TASK 78-36-00-410-806-A | Closing of the Thrust Reverser Cowl Doors |
Subtask 30-21-51-861-067-A Subtask 30-21-51-941-073-A
B. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Make sure that the WARNING NOTICE(S) is in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Make sure that the WARNING NOTICE(S) is in position to tell persons not to energize FADEC 1(2).
Subtask 30-21-51-865-103-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Make sure that the WARNING NOTICE(S) is in position to tell persons not to operate:
- The ENG/MODE selector switch, and
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Make sure that the WARNING NOTICE(S) is in position to tell persons not to energize FADEC 1(2).
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 30-21-51-010-104-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENGINE 1) | |||
| 122VU | ANTI ICE/ENG/1 | 1DN1 | X10 |
| FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENGINE 2) | |||
| 122VU | ANTI ICE/ENG/2 | 1DN2 | W10 |
D. Get Access
(1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
Subtask 30-21-51-040-067-A (1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
E. Deactivation of the Thrust Reverser System for Ground Maintenance
Subtask 30-21-51-010-106-A WARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
(1) Make sure that you did the deactivation of the thrust reverser system for nacelle maintenance (Ref. AMM TASK 78-30-00-040-807). F. Get Access
(1) Make sure that the thrust reverser cowl-doors are open (Ref. AMM TASK 78-36-00-010-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position.
4. Procedure(1) Make sure that the thrust reverser cowl-doors are open (Ref. AMM TASK 78-36-00-010-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position.
Subtask 30-21-51-420-063-A
A. Installation of the FWD Air-Intake Anti-Ice Valve Ventilation Lines
(2) TORQUE the hose clamp (1) to between 11 and 9 lbf.in (0.12 and 0.10 m.daN )
.
(3) Align the two holes at the aft end of the NAI tube (4) with the mating holes in the bracket on Pressure Regulating and Shut-Off Valve 2 (PRSOV2) (5).
(4) Install the two bolts (3) that attach the NAI tube (4) to PRSOV2 (5).
(5) TORQUE the two bolts (3) to between 124 and 106 lbf.in (1.40 and 1.20 m.daN )
.
(6) Connect the forward end of the NAI holes to the Variable Bleed Valve (VBV) exit duct (6) using the hose clamp (1).
(7) TORQUE the hose clamp (1) to between 11 and 9 lbf.in (0.12 and 0.10 m.daN )
.
Subtask 30-21-51-710-063-A NOTE: If new hose clamps (2) are installed, trim the tail of the clamp to no longer than 0.5 inches (12.7 mm) beyond the torque screw housing.
(1) Attach the Nacelle Anti-Icing (NAI) hose (2) to the NAI tube (4) with hose clamp (1). (2) TORQUE the hose clamp (1) to between 11 and 9 lbf.in (0.12 and 0.10 m.daN )
. (3) Align the two holes at the aft end of the NAI tube (4) with the mating holes in the bracket on Pressure Regulating and Shut-Off Valve 2 (PRSOV2) (5).
(4) Install the two bolts (3) that attach the NAI tube (4) to PRSOV2 (5).
(5) TORQUE the two bolts (3) to between 124 and 106 lbf.in (1.40 and 1.20 m.daN )
. (6) Connect the forward end of the NAI holes to the Variable Bleed Valve (VBV) exit duct (6) using the hose clamp (1).
(7) TORQUE the hose clamp (1) to between 11 and 9 lbf.in (0.12 and 0.10 m.daN )
. B. Operational Test
(1) Do the operational test of the bleed air system (Ref. AMM TASK 36-11-00-710-803).
5. Close-up(1) Do the operational test of the bleed air system (Ref. AMM TASK 36-11-00-710-803).
Subtask 30-21-51-410-087-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Close the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-806).
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
Subtask 30-21-51-440-062-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Close the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-806).
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
B. Do the reactivation of the thrust reverser system after nacelle maintenance (Ref. AMM TASK 78-30-00-440-807).
Subtask 30-21-51-410-088-A C. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Remove the WARNING NOTICE(S).
Subtask 30-21-51-865-101-A (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Remove the WARNING NOTICE(S).
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 30-21-51-862-061-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENGINE 1) | |||
| 122VU | ANTI ICE/ENG/1 | 1DN1 | X10 |
| FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENGINE 2) | |||
| 122VU | ANTI ICE/ENG/2 | 1DN2 | W10 |
FWD Air-Intake Anti-Ice Valve Ventilation-Lines