W DOC AIRBUS | AMM A320F

Reactivation of the NAI Lower Valve with the Thrust Reverser Door Open


TASK 30-21-00-440-804-A
Reactivation of the NAI Lower Valve with the Thrust Reverser Door Open


WARNING: WEAR APPLICABLE PERSONAL PROTECTIVE EQUIPMENT (PPE) WHEN YOU DO THIS TASK. BEFORE YOU USE PPE, READ, UNDERSTAND AND OBEY ALL INSTRUCTIONS FOR ITS USE. THESE INSTRUCTIONS INCLUDE INSTRUCTIONS FROM THE MANUFACTURER, YOUR EMPLOYER AND GOVERNMENT REGULATIONS. YOU CAN GET INJURED IF YOU DO NOT USE PPE. GET INSTRUCTIONS FROM YOUR EMPLOYER ON WHICH PPE IS NECESSARY.
WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
CAUTION: MAKE SURE THAT THERE IS ALWAYS AN ANTI-ICE VALVE (UPPER OR LOWER) ACTIVATED DURING FLIGHT. IF THE TWO VALVES ARE DEACTIVATED, DAMAGE TO COMPONENTS CAN OCCUR.
ZONE: 210
ZONE: 400
FIN: 4011DN ** ON A/C NOT FOR ALL
1. Reason for the Job
MMEL 30-21-01B
ENGINE ANTI-ICE VALVE
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
DRIVE 1/4 IN - SQUARE
No specific
1
EXTENSION LENGHT 6 IN (152,4 MM)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
WRENCH 1/4 IN - RATCHET
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
400
POWER PLANT, NACELLES AND PYLONS
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR, 452AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-00-00-860-833-A
Procedure to Prevent Engine Motoring
TASK 71-13-00-010-802-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-802-A
Closing of the Fan Cowl Doors
TASK 78-30-00-040-805-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-30-00-440-805-A
Reactivation of the Thrust Reverser System after Ground Maintenance
TASK 78-36-00-010-802-A
Opening of the Thrust Reverser Cowl-Doors
TASK 78-36-00-410-802-A
Closing of the Thrust Reverser Cowl-Doors
3. Job Set-up
Subtask 30-21-00-941-061-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 30-21-00-865-100-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENG 1)
122VUANTI ICE/ENG/11DN1X10
FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENG 2)
122VUANTI ICE/ENG/21DN2W10
Subtask 30-21-00-010-097-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
Subtask 30-21-00-040-076-A ** ON A/C NOT FOR ALL
D. Deactivation of the Thrust Reverser System for Ground Maintenance
WARNING: YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
   (1) Do the deactivation of the thrust reverser system for ground maintenance (Ref. AMM TASK 78-30-00-040-805).
Subtask 30-21-00-010-098-A ** ON A/C NOT FOR ALL
E. Get Access
   (1) Open the right thrust reverser cowl door (Ref. AMM TASK 78-36-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
452AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR
4. Procedure
Subtask 30-21-00-440-078-A ** ON A/C NOT FOR ALL
A. Reactivation of the NAI Lower Valve with the Thrust Reverser Door Open
CAUTION: REMOVE THE PROTECTION COVERS FROM THE OPENINGS AS NECESSARY TO PREVENT ENGINE DAMAGE.
CAUTION: WIPE CLEAN ALL PARTS AND TOOLS AS NECESSARY TO REMOVE UNWANTED DEBRIS AND PREVENT DAMAGE TO THE ENGINE.
   (1) Unlock the NAI lower valve:
     (a) Put a DRIVE 1/4 IN - SQUARE with an EXTENSION LENGHT 6 IN (152,4 MM) in the square hole of the manual override interface.
CAUTION: WHEN YOU TURN THE MANUAL OVERRIDE INTERFACE, DO NOT APPLY A FORCE OF MORE THAN 115 lbf.in (1.3 m.daN). IF YOU DO NOT OBEY THIS INSTRUCTION, YOU CAN CAUSE INTERNAL DAMAGE TO THE NAI VALVE.
     (b) Push in the DRIVE 1/4 IN - SQUARE with the EXTENSION LENGHT 6 IN (152,4 MM) and turn the interface 270 degrees clockwise with a WRENCH 1/4 IN - RATCHET.
     (c) Release the pressure on the interface.
     (d) Make sure that the manual override interface locks in position.
     (e) Make sure that the notch is adjacent to the words "UNLOCKED".
     (f) Move the interface a small distance if it is not locked in position.
5. Close-up
Subtask 30-21-00-410-100-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the right thrust reverser cowl-door (Ref. AMM TASK 78-36-00-410-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
452AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR
Subtask 30-21-00-440-079-A ** ON A/C NOT FOR ALL
B. Do the reactivation of the thrust reverser system after ground maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 30-21-00-410-101-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
   (2) Remove the WARNING NOTICE(S).
Subtask 30-21-00-865-101-A ** ON A/C NOT FOR ALL
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENG 1)
122VUANTI ICE/ENG/11DN1X10
FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENG 2)
122VUANTI ICE/ENG/21DN2W10
[Rev.10 from 2021] 2026.04.01 00:28:54 UTC