W DOC AIRBUS | AMM A320F

Reactivation of the Engine Anti Ice Fault LT - Valve


TASK 30-21-00-440-003-A
Reactivation of the Engine Anti Ice Fault LT - Valve


1. Reason for the Job
NOTE: This deactivation task is not related to an AFM-CDL/MMEL item
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
3. Job Set-up
Subtask 30-21-00-861-058-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 30-21-00-860-058-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
     (c) Make sure that the WARNING NOTICE(S) are in position to tell persons not to operate:
  • The ENG/MODE selector switch, and
  • The ENG/MASTER 1(2) control switch.
   (2) On the ENG section of maintenance panel 50VU:
     (a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Make sure that the WARNING NOTICE(S) is in position to tell persons not to energize FADEC 1(2).
   (3) On the ANTI ICE section of the panel 25VU:
     (a) Release the ANTI ICE/ENG 1(2) pushbutton switch (the ON legend goes off).
Subtask 30-21-00-865-062-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 1000EM1 (ENGINE1)
122VUANTI ICE/ENG/11DN1X10
FOR FIN: 1000EM2 (ENGINE2)
122VUANTI ICE/ENG/21DN2W10
Subtask 30-21-00-010-057-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Open the fan-cowl doors (Ref. AMM TASK 71-13-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR
4. Procedure
Subtask 30-21-00-440-052-A ** ON A/C NOT FOR ALL
A. Reactivation of the Anti Ice Fault LT Valve
   (1) On the valve 4000DN, remove the safety pin which locks the override control.
Subtask 30-21-00-865-056-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 1000EM1 (ENGINE1)
122VUANTI ICE/ENG/11DN1X10
FOR FIN: 1000EM2 (ENGINE2)
122VUANTI ICE/ENG/21DN2W10
Subtask 30-21-00-810-052-A ** ON A/C NOT FOR ALL
C. Do the system troubleshooting operations (Ref. TSM 3021).
5. Close-up
Subtask 30-21-00-410-057-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan-cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR
   (3) Remove the WARNING NOTICE(S).
Subtask 30-21-00-862-058-A ** ON A/C NOT FOR ALL
B. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.01 00:28:42 UTC