Reactivation of the Engine Anti Ice Fault LT - Valve
TASK 30-21-00-440-003-A
Reactivation of the Engine Anti Ice Fault LT - Valve
1. Reason for the Job
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 30-21-00-861-058-A ** ON A/C NOT FOR ALL Subtask 30-21-00-860-058-A ** ON A/C NOT FOR ALL
Subtask 30-21-00-440-052-A ** ON A/C NOT FOR ALL
Subtask 30-21-00-410-057-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:28:42 UTC
Reactivation of the Engine Anti Ice Fault LT - Valve
1. Reason for the Job
NOTE: This deactivation task is not related to an AFM-CDL/MMEL item
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
Subtask 30-21-00-861-058-A ** ON A/C NOT FOR ALL Subtask 30-21-00-860-058-A ** ON A/C NOT FOR ALL
B. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Make sure that the WARNING NOTICE(S) are in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Make sure that the WARNING NOTICE(S) is in position to tell persons not to energize FADEC 1(2).
(3) On the ANTI ICE section of the panel 25VU:
(a) Release the ANTI ICE/ENG 1(2) pushbutton switch (the ON legend goes off).
Subtask 30-21-00-865-062-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Make sure that the WARNING NOTICE(S) are in position to tell persons not to operate:
- The ENG/MODE selector switch, and
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Make sure that the WARNING NOTICE(S) is in position to tell persons not to energize FADEC 1(2).
(3) On the ANTI ICE section of the panel 25VU:
(a) Release the ANTI ICE/ENG 1(2) pushbutton switch (the ON legend goes off).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 30-21-00-010-057-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 1000EM1 (ENGINE1) | |||
| 122VU | ANTI ICE/ENG/1 | 1DN1 | X10 |
| FOR FIN: 1000EM2 (ENGINE2) | |||
| 122VU | ANTI ICE/ENG/2 | 1DN2 | W10 |
D. Get Access
(1) Open the fan-cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR
4. Procedure(1) Open the fan-cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR
Subtask 30-21-00-440-052-A ** ON A/C NOT FOR ALL
A. Reactivation of the Anti Ice Fault LT Valve
(1) On the valve 4000DN, remove the safety pin which locks the override control.
Subtask 30-21-00-865-056-A ** ON A/C NOT FOR ALL (1) On the valve 4000DN, remove the safety pin which locks the override control.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 30-21-00-810-052-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 1000EM1 (ENGINE1) | |||
| 122VU | ANTI ICE/ENG/1 | 1DN1 | X10 |
| FOR FIN: 1000EM2 (ENGINE2) | |||
| 122VU | ANTI ICE/ENG/2 | 1DN2 | W10 |
C. Do the system troubleshooting operations (Ref. TSM 3021).
5. Close-upSubtask 30-21-00-410-057-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan-cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR
(3) Remove the WARNING NOTICE(S).
Subtask 30-21-00-862-058-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan-cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR
(3) Remove the WARNING NOTICE(S).
Anti-Ice Valve of the Engine Air Intake