Deactivation of the Applicable Anti-ice Valve after a NAI SYSTEM FAILED CLOSED Fault
TASK 30-21-00-040-809-A
Deactivation of the Applicable Anti-ice Valve after a NAI SYSTEM FAILED CLOSED Fault
MMEL 30-21-01B
ENGINE ANTI-ICE VALVE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 30-21-00-861-083-A ** ON A/C NOT FOR ALL Subtask 30-21-00-941-070-A ** ON A/C NOT FOR ALL
Subtask 30-21-00-040-096-A ** ON A/C NOT FOR ALL
Subtask 30-21-00-942-060-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:19:55 UTC
Deactivation of the Applicable Anti-ice Valve after a NAI SYSTEM FAILED CLOSED Fault
WARNING:
WEAR APPLICABLE PERSONAL PROTECTIVE EQUIPMENT (PPE) WHEN YOU DO THIS TASK. BEFORE YOU USE PPE, READ, UNDERSTAND AND OBEY ALL INSTRUCTIONS FOR ITS USE. THESE INSTRUCTIONS INCLUDE INSTRUCTIONS FROM THE MANUFACTURER, YOUR EMPLOYER AND GOVERNMENT REGULATIONS. YOU CAN GET INJURED IF YOU DO NOT USE PPE. GET INSTRUCTIONS FROM YOUR EMPLOYER ON WHICH PPE IS NECESSARY.
1. Reason for the JobMMEL 30-21-01B
ENGINE ANTI-ICE VALVE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 30-21-00-040-803-A | Deactivation of the NAI Upper Valve with the Thrust Reverser Door Open |
| TASK 30-21-00-040-803-A-01 | Deactivation of the NAI Upper Valve |
| TASK 30-21-00-040-804-A | Deactivation of the NAI Lower Valve with the Thrust Reverser Door Open |
| TASK 30-21-00-440-803-A | Reactivation of the NAI Upper Valve with the Thrust Reverser Door Open |
| TASK 30-21-00-440-803-A-01 | Reactivation of the NAI Upper Valve |
| TASK 30-21-00-440-804-A | Reactivation of the NAI Lower Valve with the Thrust Reverser Door Open |
| TASK 30-21-00-710-002-A | Operational Check of the Engine-Air-Intake Ice-Protection System (with the Engines in operation) |
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-30-00-440-805-A | Reactivation of the Thrust Reverser System after Ground Maintenance |
Subtask 30-21-00-861-083-A ** ON A/C NOT FOR ALL Subtask 30-21-00-941-070-A ** ON A/C NOT FOR ALL
B. Safety Precautions
(1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 30-21-00-865-121-A ** ON A/C NOT FOR ALL (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 30-21-00-040-095-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENG 1) | |||
| 122VU | ANTI ICE/ENG/1 | 1DN1 | X10 |
| FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENG 2) | |||
| 122VU | ANTI ICE/ENG/2 | 1DN2 | W10 |
D. Deactivation of the Thrust Reverser for Maintenance
4. ProcedureWARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
(1) Do the deactivation of the thrust reverser system for ground maintenance (Ref. AMM TASK 78-30-00-040-805). Subtask 30-21-00-040-096-A ** ON A/C NOT FOR ALL
A. Deactivation of the Applicable Anti Ice Valve after a NAI SYSTEM FAILED CLOSED Fault
(2) Do an operational test of the engine-air-intake ice-protection system (Ref. AMM TASK 30-21-00-710-002).
(3) If the maintenance message does not show, keep the nacelle anti-ice upper-valve in the deactivated position and do step 4.A.(9).
(4) If the maintenance message shows, do the reactivation of the nacelle anti-ice upper-valve (Ref. AMM TASK 30-21-00-440-803)
(5) Do the deactivation of the nacelle anti-ice lower-valve (Ref. AMM TASK 30-21-00-040-804).
(6) Do an operational test of the engine-air-intake ice-protection system (Ref. AMM TASK 30-21-00-710-002).
(7) If the maintenance message does not show, keep the nacelle anti-ice lower-valve in the deactivated position and do step 4.A.(9).
(8) If the maintenance message shows, do the reactivation of the nacelle anti-ice lower-valve (Ref. AMM TASK 30-21-00-440-804).
(9) Make an entry in the log book.
5. Close-upCAUTION:
REMOVE AND INSTALL PROTECTION COVERS AS NECESSARY TO PREVENT DAMAGE TO THE ENGINE AND ADJACENT COMPONENTS.
CAUTION:
WIPE CLEAN ALL PARTS AND TOOLS AS NECESSARY TO REMOVE UNWANTED DEBRIS AND PREVENT DAMAGE TO THE ENGINE.
(1) Do the deactivation of the nacelle anti-ice upper-valve (Ref. AMM TASK 30-21-00-040-803). (2) Do an operational test of the engine-air-intake ice-protection system (Ref. AMM TASK 30-21-00-710-002).
(3) If the maintenance message does not show, keep the nacelle anti-ice upper-valve in the deactivated position and do step 4.A.(9).
(4) If the maintenance message shows, do the reactivation of the nacelle anti-ice upper-valve (Ref. AMM TASK 30-21-00-440-803)
(5) Do the deactivation of the nacelle anti-ice lower-valve (Ref. AMM TASK 30-21-00-040-804).
(6) Do an operational test of the engine-air-intake ice-protection system (Ref. AMM TASK 30-21-00-710-002).
(7) If the maintenance message does not show, keep the nacelle anti-ice lower-valve in the deactivated position and do step 4.A.(9).
(8) If the maintenance message shows, do the reactivation of the nacelle anti-ice lower-valve (Ref. AMM TASK 30-21-00-440-804).
(9) Make an entry in the log book.
Subtask 30-21-00-942-060-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the WARNING NOTICE(S).
Subtask 30-21-00-440-092-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the WARNING NOTICE(S).
B. Do the reactivation of the thrust reverser system after ground maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 30-21-00-865-122-A ** ON A/C NOT FOR ALL C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 30-21-00-862-084-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENG 1) | |||
| 122VU | ANTI ICE/ENG/1 | 1DN1 | X10 |
| FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENG 2) | |||
| 122VU | ANTI ICE/ENG/2 | 1DN2 | W10 |