Deactivation of the NAI Upper Valve with the Thrust Reverser Door Open
TASK 30-21-00-040-803-A
Deactivation of the NAI Upper Valve with the Thrust Reverser Door Open
MMEL 30-21-01B
ENGINE ANTI-ICE VALVE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 30-21-00-941-058-A ** ON A/C NOT FOR ALL
Subtask 30-21-00-410-095-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:28:47 UTC
Deactivation of the NAI Upper Valve with the Thrust Reverser Door Open
WARNING:
WEAR APPLICABLE PERSONAL PROTECTIVE EQUIPMENT (PPE) WHEN YOU DO THIS TASK. BEFORE YOU USE PPE, READ, UNDERSTAND AND OBEY ALL INSTRUCTIONS FOR ITS USE. THESE INSTRUCTIONS INCLUDE INSTRUCTIONS FROM THE MANUFACTURER, YOUR EMPLOYER AND GOVERNMENT REGULATIONS. YOU CAN GET INJURED IF YOU DO NOT USE PPE. GET INSTRUCTIONS FROM YOUR EMPLOYER ON WHICH PPE IS NECESSARY.
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
CAUTION:
MAKE SURE THAT THERE IS ALWAYS AN ANTI-ICE VALVE (UPPER OR LOWER) ACTIVATED DURING FLIGHT.
IF THE TWO VALVES ARE DEACTIVATED, DAMAGE TO COMPONENTS CAN OCCUR.
1. Reason for the JobMMEL 30-21-01B
ENGINE ANTI-ICE VALVE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | DRIVE 1/4 IN - SQUARE |
| No specific | 1 | EXTENSION LENGHT 6 IN (152,4 MM) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| No specific | 1 | WRENCH 1/4 IN - RATCHET |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1) | |
| 437AL, 438AR, 452AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2) | |
| 447AL, 448AR, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 71-13-00-010-802-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-802-A | Closing of the Fan Cowl Doors |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-30-00-440-805-A | Reactivation of the Thrust Reverser System after Ground Maintenance |
| TASK 78-36-00-010-802-A | Opening of the Thrust Reverser Cowl-Doors |
| TASK 78-36-00-410-802-A | Closing of the Thrust Reverser Cowl-Doors |
Subtask 30-21-00-941-058-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 30-21-00-865-094-A ** ON A/C NOT FOR ALL (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 30-21-00-010-091-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENG 1) | |||
| 122VU | ANTI ICE/ENG/1 | 1DN1 | X10 |
| FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENG 2) | |||
| 122VU | ANTI ICE/ENG/2 | 1DN2 | W10 |
C. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
438AR 437AL
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
448AR 447AL
Subtask 30-21-00-040-072-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
438AR 437AL
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
448AR 447AL
D. Deactivation of the Thrust Reverser for Maintenance
Subtask 30-21-00-010-092-A ** ON A/C NOT FOR ALL WARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
(1) Do the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-805). E. Get Access
(1) Open the right thrust reverser cowl-door (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR
4. Procedure(1) Open the right thrust reverser cowl-door (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR
CAUTION:
REMOVE AND INSTALL PROTECTION COVERS AS NECESSARY TO PREVENT DAMAGE TO THE ENGINE AND ADJACENT COMPONENTS.
CAUTION:
WIPE CLEAN ALL PARTS AND TOOLS AS NECESSARY TO REMOVE UNWANTED DEBRIS AND PREVENT DAMAGE TO THE ENGINE.
Subtask 30-21-00-040-073-A ** ON A/C NOT FOR ALL A. Deactivation of the NAI Upper Valve with the Thrust Reverser Door Open
(1) Lock the NAI upper valve in the open position:
(a) Put a DRIVE 1/4 IN - SQUARE with an EXTENSION LENGHT 6 IN (152,4 MM) in the square hole of the manual override interface.
(c) Release the pressure on the interface.
(d) Make sure that the manual override interface locks in position.
(e) Make sure that the notch is adjacent to the words "LOCKED OPEN".
(f) Move the interface a small distance if it is not locked in position.
5. Close-up(1) Lock the NAI upper valve in the open position:
(a) Put a DRIVE 1/4 IN - SQUARE with an EXTENSION LENGHT 6 IN (152,4 MM) in the square hole of the manual override interface.
CAUTION:
WHEN YOU TURN THE MANUAL OVERRIDE INTERFACE, DO NOT APPLY A FORCE OF MORE THAN 115 lbf.in (1.3 m.daN). IF YOU DO NOT OBEY THIS INSTRUCTION, YOU CAN CAUSE INTERNAL DAMAGE TO THE NAI VALVE.
(b) Push in the DRIVE 1/4 IN - SQUARE with the EXTENSION LENGHT 6 IN (152,4 MM) and turn the interface 270 degrees counterclockwise with a WRENCH 1/4 IN - RATCHET. (c) Release the pressure on the interface.
(d) Make sure that the manual override interface locks in position.
(e) Make sure that the notch is adjacent to the words "LOCKED OPEN".
(f) Move the interface a small distance if it is not locked in position.
Subtask 30-21-00-410-095-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the right thrust reverser cowl-door (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR
Subtask 30-21-00-440-073-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the right thrust reverser cowl-door (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR
B. Do the reactivation of the thrust reverser system after maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 30-21-00-410-094-A ** ON A/C NOT FOR ALL C. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(2) Remove the WARNING NOTICE(S).
Subtask 30-21-00-865-095-A ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(2) Remove the WARNING NOTICE(S).
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 30-21-00-942-057-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENG 1) | |||
| 122VU | ANTI ICE/ENG/1 | 1DN1 | X10 |
| FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENG 2) | |||
| 122VU | ANTI ICE/ENG/2 | 1DN2 | W10 |
E. Put the aircraft back to its initial configuration.
(1) Put a WARNING NOTICE(S) in position in the cockpit to tell persons that the NAI upper valve is deactivated in the open position.
(2) Make an entry in the logbook.
(1) Put a WARNING NOTICE(S) in position in the cockpit to tell persons that the NAI upper valve is deactivated in the open position.
(2) Make an entry in the logbook.
Upper Anti-ice Valve with the Thrust Reverser Door Open