W DOC AIRBUS | AMM A320F

Deactivation of the Engine Anti Ice Fault LT - Valve


TASK 30-21-00-040-003-A
Deactivation of the Engine Anti Ice Fault LT - Valve


1. Reason for the Job
NOTE: This deactivation task is not related to an AFM-CDL/MMEL item
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
3. Job Set-up
Subtask 30-21-00-861-059-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 30-21-00-860-056-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
     (c) Put a WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
   (2) On the ENG section maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize FADEC 1(2).
   (3) On the ANTI ICE section of the panel 25VU:
     (a) Release the ANTI ICE/ENG 1(2) pushbutton switch (the ON legend goes off).
Subtask 30-21-00-865-055-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 1000EM1 (ENGINE1)
122VUANTI ICE/ENG/11DN1X10
FOR FIN: 1000EM2 (ENGINE2)
122VUANTI ICE/ENG/21DN2W10
Subtask 30-21-00-010-056-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Open the fan-cowl doors (Ref. AMM TASK 71-13-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR
4. Procedure
Subtask 30-21-00-040-052-A ** ON A/C NOT FOR ALL
A. Deactivation of the Anti Ice Fault LT Valve
CAUTION: DO NOT APPLY A TORQUE OF MORE THAN 70 LBF.IN. WHEN YOU OPEN OR CLOSE THE VALVE MANUALLY. HIGH TORQUE CAN CAUSE DAMAGE TO THE INTERNAL SHAFT IN THE VALVE. IF THE VALVE DOES NOT OPEN OR CLOSE WHEN YOU APPLY THE SPECIFIED TORQUE, YOU MUST DO AN OVERHAUL OF THE VALVE.
   (1) On the air-intake anti-ice valve 4000DN:
     (a) turn and set the manual override control to the OP position with a hexagonal wrench. Lock it in this position with a safety pin.
   (2) On the overhead panel 25VU:
     (a) Push the ANTI ICE/ENG 1(2) pushbutton switch.
5. Close-up
Subtask 30-21-00-865-057-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 1000EM1 (ENGINE1)
122VUANTI ICE/ENG/11DN1X10
FOR FIN: 1000EM2 (ENGINE2)
122VUANTI ICE/ENG/21DN2W10
Subtask 30-21-00-410-056-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan-cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR
Subtask 30-21-00-860-057-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) Remove the WARNING NOTICE(S).
   (2) On the ANTI ICE part of the panel 25VU, make sure that the ENG 1(2) pushbutton switch is pushed. (On the pushbutton switch, the ON legend is on).
   (3) Put a WARNING NOTICE(S) in position in the cockpit. This tells persons that the anti ice valve is deactivated in the open position.
   (4) Make an entry in the logbook.
Subtask 30-21-00-862-059-A ** ON A/C NOT FOR ALL
D. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.01 00:28:41 UTC