Remove Wing Anti-Icing Filter for In Shop Cleaning
TASK 30-11-51-960-802-A
Remove Wing Anti-Icing Filter for In Shop Cleaning
Refer to the MPD TASK: 301151-02
REMOVE WING ANTI-ICING FILTER FOR IN SHOP CLEANING
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Expendable Parts
D. Referenced Information
3. Job Set-up
Subtask 30-11-51-941-059-A
Subtask 30-11-51-960-052-A
Subtask 30-11-51-865-059-A
[Rev.10 from 2021]
2026.04.01 00:28:32 UTC
Remove Wing Anti-Icing Filter for In Shop Cleaning
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
DO NOT TOUCH THE ANTI-ICE DUCTS UNTIL THEY ARE COOL. THE TEMPERATURE OF THE DUCTS STAYS HIGH FOR SOME TIME AFTER THE ENGINE STOPS.
1. Reason for the JobRefer to the MPD TASK: 301151-02
REMOVE WING ANTI-ICING FILTER FOR IN SHOP CLEANING
NOTE: The wing anti-ice control valve is an interchangeable part.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 520 | LEFT WING FIXED LEADING EDGE |
| 620 | RIGHT WING FIXED LEADING EDGE |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 12 | FILTER | AIPC 30-11-51-02-250 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 30-11-51-000-001-A | Removal of the Wing Anti-Ice Control-Valve |
| TASK 30-11-51-000-002-A | Removal of the Anti-Ice Valve Filter |
| TASK 30-11-51-400-001-A | Installation of the Wing Anti-Ice Control-Valve |
| TASK 30-11-51-400-002-A | Installation of the Anti-Ice Valve Filter |
Subtask 30-11-51-941-059-A
A. Safety Precautions
(1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(2) Before you do work on the ice protection system, put WARNING NOTICE(S) in position to tell persons not to operate the:
Subtask 30-11-51-865-058-A (1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(2) Before you do work on the ice protection system, put WARNING NOTICE(S) in position to tell persons not to operate the:
- Pneumatic system
- Engines
- Slats
- APU switch.
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/SLT/CTL AND MONG/SYS1 | 5CV | B06 |
| ** ON A/C ALL | |||
| 49VU | ANTI ICE/WING/CTL | 2DL | C02 |
| 49VU | ANTI ICE/WING/MONG | 1DL | C01 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/SLT/CTL AND MONG/SYS1 | 5CV | B01 |
| ** ON A/C ALL | |||
| 121VU | FLIGHT CONTROLS/SLT/CTL/SYS2 | 7CV | R21 |
Subtask 30-11-51-960-052-A
A. Remove Wing Anti-Ice Valve Filter for In Shop Cleaning
(1) If necessary, remove the wing anti-ice control valve (Ref. AMM TASK 30-11-51-000-001).
(2) Remove the filter (12) from the wing anti-ice control valve (Ref. AMM TASK 30-11-51-000-002).
(3) Send the filter (12) to the workshop.
(4) Install a serviceable AIPC 30-11-51-02-250 FILTER (12) in the wing anti-ice control valve (Ref. AMM TASK 30-11-51-400-002).
(5) If removed, install the wing anti-ice control valve (Ref. AMM TASK 30-11-51-400-001).
5. Close-up(1) If necessary, remove the wing anti-ice control valve (Ref. AMM TASK 30-11-51-000-001).
(2) Remove the filter (12) from the wing anti-ice control valve (Ref. AMM TASK 30-11-51-000-002).
(3) Send the filter (12) to the workshop.
(4) Install a serviceable AIPC 30-11-51-02-250 FILTER (12) in the wing anti-ice control valve (Ref. AMM TASK 30-11-51-400-002).
(5) If removed, install the wing anti-ice control valve (Ref. AMM TASK 30-11-51-400-001).
Subtask 30-11-51-865-059-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 30-11-51-942-053-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/SLT/CTL AND MONG/SYS1 | 5CV | B06 |
| ** ON A/C ALL | |||
| 49VU | ANTI ICE/WING/CTL | 2DL | C02 |
| 49VU | ANTI ICE/WING/MONG | 1DL | C01 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/SLT/CTL AND MONG/SYS1 | 5CV | B01 |
| ** ON A/C ALL | |||
| 121VU | FLIGHT CONTROLS/SLT/CTL/SYS2 | 7CV | R21 |
B. Removal of Equipment
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the safety barriers.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the safety barriers.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Anti-Ice Valve Filter (38E93-X)