W DOC AIRBUS | AMM A320F

Reactivation of the Wing Anti-Ice Control Valve from the CLOSED position


TASK 30-11-00-440-001-A
Reactivation of the Wing Anti-Ice Control Valve from the CLOSED position


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
FIN: 10DL
FIN: 9DL
1. Reason for the Job
MMEL 30-11-01B
WING ANTI-ICE CONTROL VALVE
NOTE: The wing anti-ice control-valve is an interchangeable part.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
98D27803500001
1
LOCKING TOOL ZERO POS
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.14QFB1)
Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -
FOR [9DL] (VALVE-WING ANTI ICE CONTROL, L)
(Material No.14QFB1)
Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [10DL] (VALVE-WING ANTI ICE CONTROL, R)
622WB
622YB
FOR [9DL] (VALVE-WING ANTI ICE CONTROL, L)
522YB
522WB
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 30-11-51-000-001-A
Removal of the Wing Anti-Ice Control-Valve
TASK 30-11-51-400-001-A
Installation of the Wing Anti-Ice Control-Valve
TASK 57-41-37-000-004-A
Removal of the Pressure Relief Panels
TASK 57-41-37-000-008-A
Removal of the Access Panel
TASK 57-41-37-400-002-A
Installation of the Pressure Relief Panels
TASK 57-41-37-400-008-A
Installation of the Access Panel
3. Job Set-up
Subtask 30-11-00-941-060-A
A. Safety Precautions
   (1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
   (2) Before you do work on the Ice Protection system, put the WARNING NOTICE(S) in position to tell persons not to operate the:
  • Pneumatic system
  • Engines
  • Slats
  • APU.
   (3) Install a 98D27803500001 LOCKING TOOL ZERO POS on the flap and slat control lever.
   (4) On panel 191DB, put the WARNING NOTICE(S) in position to tell persons not to pressurize the bleed air system.
Subtask 30-11-00-865-053-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB06
** ON A/C ALL
49VUANTI ICE/WING/CTL2DLC02
49VUANTI ICE/WING/MONG1DLC01
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB01
** ON A/C ALL
121VUAPU/APU/CTL2KDL42
121VUFLIGHT CONTROLS/SLT/CTL/SYS27CVR21
Subtask 30-11-00-010-053-B ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put an ACCESS PLATFORM 3M (10 FT) in position below zone 522(622).
   (2) Remove the applicable access panel (Ref. AMM TASK 57-41-37-000-008):
     (a) FOR [9DL] (VALVE-WING ANTI ICE CONTROL, L)
  • Remove access panel 522WB from panel 522AB.
     (b) FOR [10DL] (VALVE-WING ANTI ICE CONTROL, R)
  • Remove access panel 622WB from panel 622AB.
Subtask 30-11-00-010-053-C ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below zone 522(622).
   (2) Remove the applicable access panel (Ref. AMM TASK 57-41-37-000-004):
     (a) FOR [9DL] (VALVE-WING ANTI ICE CONTROL, L)
  • Remove access panel 522YB.
     (b) FOR [10DL] (VALVE-WING ANTI ICE CONTROL, R)
  • Remove access panel 622YB.
4. Procedure
Subtask 30-11-00-440-054-A
A. Replace the Wing Anti-Ice Control-Valve
   (1) If you know that the deactivated wing anti-ice control-valve(s) is (are) defective, replace the defective valve(s) (Ref. AMM TASK 30-11-51-000-001) (Ref. AMM TASK 30-11-51-400-001).
Subtask 30-11-00-440-053-A
B. Trouble Shoot the Applicable Wing Anti-Ice Control-Valve (for part number SAS 911-002A)
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
   (1) If you do not know the cause of the defect, do these subsequent steps:
     (a) Remove and discard the lockwire from the bolt (1).
     (b) Remove the bolt (1) from the indicator (2).
     (c) Install the bolt (1) in the stowage position.
     (d) Safety the bolt (1) with 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
     (e) Slowly operate the indicator (2) with your hand to make sure that it moves freely.
Subtask 30-11-00-440-058-A
C. Trouble Shoot the Applicable Wing Anti-Ice Control-Valve (for part number 38E93-X)
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
   (1) If you do not know the cause of the defect, do these subsequent steps:
     (a) FOR [9DL] (VALVE-WING ANTI ICE CONTROL, L)
  • Remove and discard the lockwire from the locking screw (10)
  • Remove the locking screw (10) from the locking hole (11) of the indicator (12).
     (b) FOR [10DL] (VALVE-WING ANTI ICE CONTROL, R)
  • Push the locking plate (15) to its middle position.
NOTE: The locking plate (15) has three positions:
  • When in its middle position, the locking plate (15) is unlocked.
  • When pushed fully left or fully right, the locking plate (15) locks the rod (14).
  • Make sure that you hear a click when you put the locking plate (15) in the correct position.
     (c) FOR [9DL] (VALVE-WING ANTI ICE CONTROL, L)
  • Install the locking screw (10) in the stowage position
  • Safety the locking screw (10) with 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
   (2) Do the test that follows:
     (a) FOR [9DL] (VALVE-WING ANTI ICE CONTROL, L)
  • Slowly operate the indicator (12) with your hand to make sure that it moves freely.
     (b) FOR [10DL] (VALVE-WING ANTI ICE CONTROL, R)
  • Slowly operate the rod (14) with your hand to make sure that it moves freely.
Subtask 30-11-00-865-070-A
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUANTI ICE/WING/CTL2DLC02
49VUANTI ICE/WING/MONG1DLC01
121VUAPU/APU/CTL2KDL42
5. Close-up
Subtask 30-11-00-860-066-A
A. Aircraft Configuration
   (1) Remove the placard (that told the aircraft crew that the wing anti-ice control-valve(s) were deactivated).
Subtask 30-11-00-410-053-B ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the applicable access panel (Ref. AMM TASK 57-41-37-400-008):
     (a) FOR [9DL] (VALVE-WING ANTI ICE CONTROL, L)
  • Install access panel 522WB.
     (b) FOR [10DL] (VALVE-WING ANTI ICE CONTROL, R)
  • Install access panel 622WB.
Subtask 30-11-00-410-053-C ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the applicable access panel (Ref. AMM TASK 57-41-37-400-002):
     (a) FOR [9DL] (VALVE-WING ANTI ICE CONTROL, L)
  • Install access panel 522YB.
     (b) FOR [10DL] (VALVE-WING ANTI ICE CONTROL, R)
  • Install access panel 622YB.
Subtask 30-11-00-865-071-A
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB06
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB01
** ON A/C ALL
121VUFLIGHT CONTROLS/SLT/CTL/SYS27CVR21
Subtask 30-11-00-942-056-A
D. Removal of Equipment
   (1) Remove the safety barriers.
   (2) Remove the WARNING NOTICE(S).
   (3) Remove the access platform(s).
   (4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
[Rev.10 from 2021] 2026.04.01 00:28:15 UTC