W DOC AIRBUS | AMM A320F

Removal of the Hydraulic Pressure Transducer


TASK 29-32-11-000-002-A
Removal of the Hydraulic Pressure Transducer


WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
FIN: 2065GN
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
CAP - BLANKING
No specific
1
CONTAINER 3 L(3/4 USGAL)
No specific
2
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
2
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
195BB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 29-00-00-864-001-A
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
TASK 29-00-00-910-002-A
Safety Procedures of the Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
3. Job Set-up
Subtask 29-32-11-865-051-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD/PRESS/XMTR1841GNC11
Subtask 29-32-11-010-051-A
B. Open the access panel 195BB.
Subtask 29-32-11-860-056-A
C. Aircraft Maintenance Configuration
WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES.
   (1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002).
   (2) Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration.
(Ref. AMM TASK 29-00-00-864-001).
   (3) Depressurize the reservoir of the Blue hydraulic system (Ref. AMM TASK 29-14-00-614-001).
   (4) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the Blue hydraulic system:
  • in the cockpit on the hydraulic section 40VU of the overhead panel
  • on the ground service panel of the Blue hydraulic system.
   (5) Put the CONTAINER 3 L(3/4 USGAL) in position below the hydraulic pressure transducer to collect hydraulic fluid.
4. Procedure
Subtask 29-32-11-020-054-B
A. Removal of the Hydraulic Pressure Transducer
   (1) Disconnect the electrical connector (1).
   (2) Put the CAP - BLANKING on the disconnected electrical connector (1).
   (3) Remove the nut (7), the washer (8), the screw (10), the bonding jumper (9) and the clamp (11) from the hydraulic pressure transducer (2).
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
   (4) Remove and discard the lockwire from the bolts (3).
   (5) Remove the two bolts (3) and the two washers (4).
   (6) Loosen the hydraulic pressure transducer (2) and remove it at the same time with the O-ring (5) from the manifold (6).
   (7) Discard the O-ring.
   (8) Install the PLUG - BLANKING in the open ports.