W DOC AIRBUS | AMM A320F

Installation of the Quantity Indicator


TASK 29-31-21-400-001-A
Installation of the Quantity Indicator


FIN: 1834GQ
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
196BB, 197CB, 197FB
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
3. Job Set-up
Subtask 29-31-21-860-050-A
A. Make sure that access door 197CB is open.
Subtask 29-31-21-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUHYDRAULIC/HYD/QTY/IND1831GQP35
4. Procedure
Subtask 29-31-21-420-050-A
A. Installation of the Quantity Indicator
NOTE: It is possible to install a quantity indicator with the unit LITERS or US GAL shown on the dial. Make sure that you install the related quantity indicator for your hydraulic system.
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Remove the blanking caps from the electrical connector (4) and the quantity indicator (2).
   (4) Make sure that all the electrical connections are clean and in the correct condition.
   (5) Connect the electrical connector (4) to the quantity indicator (2).
   (6) Install and align the quantity indicator (2) in the ground service panel (3) of the Green hydraulic system.
   (7) Tighten the screws (1).
Subtask 29-31-21-010-051-A
B. Get Access
   (1) Open the doors of the main landing gear (Ref. AMM TASK 32-12-00-010-001).
   (2) Open access doors 196BB 197FB.
Subtask 29-31-21-865-052-A
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUHYDRAULIC/HYD/QTY/IND1831GQP35
Subtask 29-31-21-710-050-A
D. Make sure that the quantity indicator shows the same hydraulic quantity as:
  • The quantity indicator of the reservoir of the Green hydraulic system
  • The quantity indicator of the reservoir of the Blue hydraulic system
  • The quantity indicator of the reservoir of the Yellow hydraulic system.
5. Close-up
Subtask 29-31-21-410-050-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close access doors 197CB 197FB 196BB.
   (3) Close the doors of the main landing gear (Ref. AMM TASK 32-12-00-410-001).
[Rev.10 from 2021] 2026.04.01 00:27:32 UTC