W DOC AIRBUS | AMM A320F

Installation of the Yellow Electric Pump Phase-Unbalance Detector


TASK 29-24-16-400-001-A
Installation of the Yellow Electric Pump Phase-Unbalance Detector


FIN: 3808GX
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
822
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 29-24-00-710-002-A
Operational Test of the Phase Unbalance Detector and the Current Transformer of the Yellow Hydraulic System
3. Job Set-up
Subtask 29-24-16-860-050-A
A. Aircraft Maintenance Configuration
   (1) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the access door 822.
   (2) Open the access door 822.
Subtask 29-24-16-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN30
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN31
** ON A/C ALL
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
4. Procedure
Subtask 29-24-16-420-050-A
A. Installation of the Yellow Electric Pump Phase-Unbalance Detector
   (1) Install the detector (1) on the support.
   (2) Install the washers (2) and the screws (3).
   (3) Remove the blanking cap from the connector (4).
   (4) Connect the electrical connector (4) to the detector (1).
Subtask 29-24-16-865-053-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN30
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN31
** ON A/C ALL
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
Subtask 29-24-16-710-050-A
C. Operational test
   (1) Do the operational test of the detector (Ref. AMM TASK 29-24-00-710-002).
5. Close-up
Subtask 29-24-16-410-050-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access door 822.
   (3) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.01 00:27:01 UTC