Removal of the Yellow Electric Pump Current Transformer
TASK 29-24-15-000-001-A
Removal of the Yellow Electric Pump Current Transformer
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 29-24-15-860-050-A
Subtask 29-24-15-020-051-A
[Rev.10 from 2021]
2026.04.01 00:26:58 UTC
Removal of the Yellow Electric Pump Current Transformer
WARNING:
ISOLATE ALL THE AIRCRAFT ELECTRICAL CIRCUITS.
CAUTION:
MAKE MATCH MARKS ON ALL THE ELECTRICAL WIRES BEFORE YOU DISCONNECT THEM. INCORRECT CONNECTION OF WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
FIN: 3807GX
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121AL, 822 |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 29-24-15-860-050-A
A. Aircraft Maintenance Configuration
(1) Make sure that the external power connector is not connected to the aircraft receptacle (20XG) (receptacle behind the access door 121AL).
Subtask 29-24-15-941-051-A (1) Make sure that the external power connector is not connected to the aircraft receptacle (20XG) (receptacle behind the access door 121AL).
B. Safety Precaution
(1) Put WARNING NOTICE(S) on the access door 121AL to tell persons not to connect the external power connector.
(2) In the cockpit, on the overhead panel 35VU, make sure that these pushbutton switches are released:
Subtask 29-24-15-010-050-A (1) Put WARNING NOTICE(S) on the access door 121AL to tell persons not to connect the external power connector.
(2) In the cockpit, on the overhead panel 35VU, make sure that these pushbutton switches are released:
- APU GEN,
- 1 BAT 2,
- GEN 1, GEN 2,
- EXT PWR.
- 21VU (EMER ELEC PWR),
- 25VU (APU),
- 35VU (ELEC)
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) at zone 121.
(2) Put the ACCESS PLATFORM 2M (6 FT) at zone 126.
(3) Open the access door 822.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) at zone 121.
(2) Put the ACCESS PLATFORM 2M (6 FT) at zone 126.
(3) Open the access door 822.
Subtask 29-24-15-020-051-A
A. Removal of the Yellow Electric Pump Current Transformer
(1) Disconnect the electrical connector (9) from the transformer (7).
(2) Put CAP - BLANKING on the disconnected electrical connector (9) and on the electrical connector of the transformer (7).
(3) Identify the electrical wires (8).
(4) Remove the nuts (3), the washers (4) and disconnect the electrical wires (8) from the contactor (2).
(5) Remove the screws (5) and the washers (6).
(6) Pull and release the transformer (7) from the electrical wires (8) and remove it.
(1) Disconnect the electrical connector (9) from the transformer (7).
(2) Put CAP - BLANKING on the disconnected electrical connector (9) and on the electrical connector of the transformer (7).
(3) Identify the electrical wires (8).
(4) Remove the nuts (3), the washers (4) and disconnect the electrical wires (8) from the contactor (2).
(5) Remove the screws (5) and the washers (6).
(6) Pull and release the transformer (7) from the electrical wires (8) and remove it.
Yellow Electric Pump Current Transformer