W DOC AIRBUS | AMM A320F

Functional Check of Thermal PTU Inhibition Logic


TASK 29-23-00-710-802-A
Functional Check of Thermal PTU Inhibition Logic


WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
1
GROUND POWER CART-HYDRAULIC
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
196BB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 12-12-29-611-001-A
Fill the Hydraulic Fluid Reservoir with a Hand Pump
TASK 12-12-29-611-002-A
Fill the Hydraulic Fluid Reservoir with a Hydraulic Service Cart
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 27-50-00-866-008-A
Extension of the Flaps on the Ground
TASK 27-50-00-866-008-A-01
Extension of the Flaps/Slats on the Ground
TASK 29-14-00-614-002-A
Pressurization of the Hydraulic Reservoirs through the Ground Connector
TASK 29-14-00-614-002-A-01
Pressurization of the Hydraulic Reservoirs with the Auxiliary Power Unit (APU)
TASK 29-23-00-860-002-A
Connection of the Isolation Coupling of the Power Transfer Unit (PTU)
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
TASK 32-00-00-860-001-A
Flight Configuration Precautions with Electrical Power
TASK 32-00-00-860-001-A-01
Flight Configuration Precautions without Electrical Power
TASK 32-00-00-860-002-A
Ground Configuration after Flight Configuration with Electrical Power
TASK 32-00-00-860-002-A-01
Ground Configuration after Flight Configuration without Electrical Power
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
TASK 32-31-71-000-001-A
Removal of the LGCIU
TASK 32-31-71-400-001-A
Installation of the LGCIU
TASK 34-10-00-860-002-A
ADIRS Start Procedure
TASK 34-12-34-000-001-A
Removal of the ADIRU
TASK 34-12-34-400-001-A
Installation of the ADIRU
TASK 53-35-13-000-002-A
Removal of the Quick-Release Access Panels from the Belly Fairing Structure
TASK 53-35-13-400-002-A
Installation of the Quick-Release Access Panels on the Belly Fairing Structure
TASK 73-25-34-000-802-A
Removal of the Engine Interface Unit (EIU)
TASK 73-25-34-400-802-A
Installation of the Engine Interface Unit (EIU)
3. Job Set-up
Subtask 29-23-00-860-070-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
   (3) Make sure that the Air Data/Inertial Reference System (ADIRS) operates (Ref. AMM TASK 34-10-00-860-002).
   (4) On the ECAM control panel, push the HYD key. Make sure that the HYD page comes into view on the ECAM lower DU.
   (5) Make sure that the ECAM does not show the warnings that follow:
  • Low air pressure in the Green, Blue or Yellow hydraulic reservoirs
  • Low fluid level in the Green, Blue or Yellow hydraulic reservoirs.
   (6) If necessary, pressurize the applicable hydraulic reservoirs (Ref. AMM TASK 29-14-00-614-002).
   (7) If necessary, add fluid to the applicable hydraulic reservoirs (Ref. AMM TASK 12-12-29-611-001) or (Ref. AMM TASK 12-12-29-611-002).
   (8) Make sure that the isolation coupling of the Power Transfer Unit (PTU) is connected (Ref. AMM TASK 29-23-00-860-002).
   (9) At the Nose Landing Gear (NLG), make sure that the towing lever is in the normal position (not in the tow position).
Subtask 29-23-00-941-050-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) As necessary, use the applicable SAFETY BARRIER(S), refer to the operator's instructions and to your local regulations.
   (2) Put the WARNING NOTICE(S) in position to tell persons that the flap system is in operation.
Subtask 29-23-00-010-054-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the main landing-gear doors (Ref. AMM TASK 32-12-00-010-001).
   (2) Open the access panel 196BB (Ref. AMM TASK 53-35-13-000-002).
   (3) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position to get access to the avionics compartment.
   (4) Do Flight Configuration Precautions with Electrical Power (Ref. AMM TASK 32-00-00-860-001).
Subtask 29-23-00-865-077-A ** ON A/C NOT FOR ALL
D. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUHYDRAULIC/PARK BRK/CTL/STBY71GGN37
121VUHYDRAULIC/PARK BRK/CTL/NORM70GGN36
121VUHYDRAULIC/SOL VALVES/G/Y/PTU1801GLN34
121VUHYDRAULIC / PTU FLT INHIB1825GLQ31
Subtask 29-23-00-865-078-A ** ON A/C NOT FOR ALL
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VULGCIU/BAT SPLY/SYS259GAR33
** ON A/C NOT FOR ALL
121VUHYDRAULIC/SOL VALVES/G/Y/PTU1801GLN34
121VUHYDRAULIC/Y HYD/PUMP ENG2/MONG3700GDQ37
121VUHYDRAULIC/LGCIU/SYS22GAQ35
121VUHYDRAULIC / PTU FLT INHIB1825GLQ31
** ON A/C NOT FOR ALL
121VULGCIU/BAT SPLY/SYS259GAR32
Subtask 29-23-00-865-079-A ** ON A/C NOT FOR ALL
F. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
123VUB HYD/ELEC PUMP2701GJAB09
Subtask 29-23-00-860-071-A ** ON A/C NOT FOR ALL
G. Aircraft Maintenance Configuration
   (1) On the nose gear leg, make sure that the towing lever is in the normal (engaged) position.
   (2) In the cockpit, make sure that the parking brake is in the OFF position.
   (3) On the overhead panel 40VU, set the PTU P/BSW to OFF (the OFF legend comes on).
Subtask 29-23-00-865-080-A ** ON A/C NOT FOR ALL
H. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
49VUENGINE/1 AND 2/IGN/SYS A1JHA03
49VUANTI ICE/PROBES/AOA/14DA1D04
49VUANTI ICE/PROBES/PHC/12DA1D03
49VUANTI ICE/PROBES/PITOT/13DA1D02
49VUCAPT/LOUD/SPKR5WWF10
** ON A/C NOT FOR ALL
121VUENGINE/ENG2/FADEC B/AND EIU24KS2Q40
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
** ON A/C NOT FOR ALL
121VUENGINE/IGN/ENG2/SYS B3JH2P42
121VUENGINE/IGN/ENG1/SYS B3JH1P41
121VUEIS/F/O/LOUD/SPKR4WWP08
** ON A/C NOT FOR ALL
121VUENGINE/ENG2/FADEC B/AND EIU24KS2R41
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R40
** ON A/C NOT FOR ALL
122VUANTI ICE/WINDOWS/R4DG2W14
122VUANTI ICE/WHC/25DG2W13
122VUANTI ICE/WINDOWS/L4DG1X14
122VUANTI ICE/WHC/15DG1X13
122VUANTI ICE/PROBES/PHC/32DA3Y16
122VUANTI ICE/PROBES/2/TAT1DA2Y15
122VUANTI ICE/PROBES/2/PITOT3DA2Y14
122VUANTI ICE/PROBES/2/AOA4DA2Y13
122VUANTI ICE/PROBES/PHC/22DA2Y12
122VUANTI ICE/PROBES/2/STATIC5DA2Y11
122VUANTI ICE/PROBES/3/PITOT3DA3Z16
122VUANTI ICE/PROBES/3/AOA4DA3Z15
122VUANTI ICE/PROBES/3/STATIC5DA3Z14
122VUANTI ICE/PROBES/1/STATIC5DA1Z13
122VUANTI ICE/PROBES/1/TAT1DA1Z12
123VUANTI ICE/L/WHSLD1DG1AF10
123VUANTI ICE/R/WHSLD1DG2AF03
Subtask 29-23-00-020-051-A ** ON A/C NOT FOR ALL
I. Removal of the Engine Interface Unit (EIU)
   (1) Remove the Engine Interface Units (EIUs):
     (a) Remove the EIU (1KS1) (Ref. AMM TASK 73-25-34-000-803).
     (b) Remove the EIU (1KS2) (Ref. AMM TASK 73-25-34-000-803).
NOTE: Removal of the EIUs can cause a EIU fault message on the SD during the test. This is permitted.
Subtask 29-23-00-860-077-A ** ON A/C NOT FOR ALL
J. Aircraft Maintenance Configuration
   (1) In the cockpit, set the ENG1 and ENG 2 Master Switches to the ON position.
Subtask 29-23-00-865-081-A ** ON A/C NOT FOR ALL
K. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUADIRS/ADIRU/2/115VAC4FP2N06
121VUADIRS/ADIRU/3/115VAC4FP3N05
Subtask 29-23-00-020-052-A ** ON A/C NOT FOR ALL
L. Removal of the ADIRU (1FP2, 1FP3)
   (1) Remove the ADIRU-2 (1FP2) and the ADIRU-3 (1FP3) (Ref. AMM TASK 34-12-34-000-001).
Subtask 29-23-00-865-090-A ** ON A/C NOT FOR ALL
M. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB06
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB01
** ON A/C NOT FOR ALL
121VUFLIGHT CONTROLS/SLT/CTL/SYS27CVR21
Subtask 29-23-00-865-091-A ** ON A/C NOT FOR ALL
N. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB07
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB02
** ON A/C NOT FOR ALL
121VUFLIGHT CONTROLS/WTB/FLP/SYS212CVP20
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
122VUFLIGHT CONTROLS/WTB/FLP/SYS110CVS07
Subtask 29-23-00-860-072-A ** ON A/C NOT FOR ALL
O. Aircraft Maintenance Configuration
   (1) Make sure that the S/F control lever position "0" is selected (Ref. AMM TASK 27-50-00-866-008).
4. Procedure
Subtask 29-23-00-710-057-A ** ON A/C NOT FOR ALL
A. Operational Check of PTU Inhibition Logic

CAUTION:
WHEN A HYDRAULIC GROUND POWER-SUPPLY OR GROUND CART IS USED, ITS
HYDRAULIC FLOW FUNCTION MUST BE LIMITED TO A MAXIMUM OF 50 LITERS PER
MINUTE AT NOMINAL PRESSURE (3000 PSI). THIS WILL PREVENT DAMAGE TO THE
PTU WHEN STARTING AT HIGH PRESSURE.
   (1) Make sure that the pressure in the Yellow hydraulic system is 3000 psi.
   (2) Use the GROUND POWER CART-HYDRAULIC and do the test that follows:
ACTION
RESULT
1.On the HP manifold of the Green hydraulic system:
  • Disconnect flight control-pressure electrical connector 10CE2-A
  • Use a shunt to connect pins A and B of the connector together to simulate high pressure condition.

2.Simulate ENG1 N2>min idle
On panel 85VU:
  • On connector 1KS1-A, use a shunt to connect pins B2E and C28 together to simulate ENG1 running.

3.On panel 40VU:
  • Set the PTU P/BSW to the ON position.
On panel 40VU:
  • The OFF legend of the P/BSW is off
  • The FAULT legend of the P/BSW is off.
On the ECAM lower DU:
  • Check that the PTU starts to supply hydraulic power from the Yellow to the Green hydraulic system.
4.Simulate ENG2 N2>min idle
On panel 86VU:
  • On connector 1KS2-A, use a shunt to connect pins B2E and C28 together to simulate ENG2 running.
On panel 40VU:
  • The OFF legend of the P/BSW is off
  • The FAULT legend of the P/BSW is off.
On the ECAM lower DU:
  • Check that the PTU is inhibited.
5.Simulate ADIRU-2>50kts
  • On ADIRU-2 (1FP2), put a ground on the connector AA, pin 2G.
On panel 40VU:
  • The OFF legend of the P/BSW is off
  • The FAULT legend of the P/BSW is off.
On the ECAM lower DU:
  • Check that the PTU supplies hydraulic power from the Yellow to the Green hydraulic system.
6.Simulate ADIRU-3>50kts
  • On ADIRU-3 (1FP3), put a ground on the connector AA, pin 2G.
On panel 40VU:
  • The OFF legend of the P/BSW is off
  • The FAULT legend of the P/BSW is off.
On the ECAM lower DU:
  • Check that the PTU supplies hydraulic power from the Yellow to the Green hydraulic system.
7.Simulate ADIRU-2<50kts
  • On ADIRU-2 (1FP2), remove the ground from connector AA, pin 2G.
On panel 40VU:
  • The OFF legend of the P/BSW is off
  • The FAULT legend of the P/BSW is off.
On the ECAM lower DU:
  • Check that the PTU supplies hydraulic power from the Yellow to the Green hydraulic system.
8.Simulate ADIRU-2>50kts
  • On ADIRU-2 (1FP2), put a ground on the connector AA, pin 2G.

Subtask 29-23-00-865-084-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VULGCIU/BAT SPLY/SYS259GAR33
** ON A/C NOT FOR ALL
121VUHYDRAULIC/LGCIU/SYS22GAQ35
** ON A/C NOT FOR ALL
121VULGCIU/BAT SPLY/SYS259GAR32
Subtask 29-23-00-710-059-A ** ON A/C NOT FOR ALL
C. Operational Check of PTU Inhibition Logic

CAUTION:
WHEN A HYDRAULIC GROUND POWER-SUPPLY OR GROUND CART IS USED, ITS
HYDRAULIC FLOW FUNCTION MUST BE LIMITED TO A MAXIMUM OF 50 LITERS PER
MINUTE AT NOMINAL PRESSURE (3000 PSI). THIS WILL PREVENT DAMAGE TO THE
PTU WHEN STARTING AT HIGH PRESSURE.
   (1) Use the GROUND POWER CART-HYDRAULIC and do the test that follows:
ACTION
RESULT
1.Simulate NLG not compressed
On panel 40VU:
  • The OFF legend of the P/BSW is off
  • The FAULT legend of the P/BSW is off.
On the ECAM lower DU:
  • Check that the PTU supplies hydraulic power from the Yellow to the Green hydraulic system.
2.Simulate RH MLG UPLOCKED
  • On LGCIU-2, put a ground on the connector AA, pin 9G.
On panel 40VU:
  • The OFF legend of the P/BSW is off
  • The FAULT legend of the P/BSW is off.
On the ECAM lower DU:
  • Check that the PTU is inhibited.
3.Set the S/F control lever to position different from "0" (Ref. AMM TASK 27-50-00-866-008).
On panel 40VU:
  • The OFF legend of the P/BSW is off
  • The FAULT legend of the P/BSW is off.
On the ECAM lower DU:
  • Check that the PTU supplies hydraulic power from the Yellow to the Green hydraulic system.
4.Set the S/F control lever back to the "0" position (Ref. AMM TASK 27-50-00-866-008).
On panel 40VU:
  • The OFF legend of the P/BSW is off
  • The FAULT legend of the P/BSW is off.
On the ECAM lower DU:
  • Check that the PTU is inhibited.
5.On the HP manifold of the Green hydraulic system:
  • Remove the shunt from control-pressure electrical connector 10CE2-A
  • Disconnect the electrical connector 1151GN-A and use a shunt to connect pins A and C of the connector 1151GN-A to simulate low pressure condition.
On panel 40VU:
  • The OFF legend of the P/BSW is OFF
  • The FAULT legend of the P/BSW comes ON after 6 seconds.
On the ECAM lower DU:
  • Check that the PTU starts and stops automatically after 6 seconds.
6.On the HP manifold of the Green hydraulic system:
  • Use a shunt to connect pins A and B of the connector 10CE2-A together to simulate high pressure condition and wait a minimum of 20 seconds.
On panel 40VU:
  • The OFF legend of the P/BSW is off
  • The FAULT legend of the P/BSW goes OFF.
On the ECAM lower DU:
  • Check that after 20 seconds the PTU starts to supply hydraulic power from the Yellow to the Green hydraulic system.
7.Remove the shunt between pins A and C of connector 1151GN-A and reconnect electrical connector 1151GN-A.
8.Simulate NLG compressed:
  • In the LGCIU-2 rack, put a ground on the connector AB, pin 9A.

Simulate ENG1 N2<min idle
On panel 85VU:
  • On connector 1KS1-A, remove the shunt between pins B2E and C28 to simulate ENG1 not running.

Simulate ENG2 N2<min idle
On panel 86VU:
  • On connector 1KS2-A, remove the shunt between pins B2E and C28 to simulate ENG2 not running.
On panel 40VU:
  • The OFF legend of the P/BSW is off
  • The FAULT legend of the P/BSW is off.
On the ECAM lower DU:
  • Check that the PTU supplies hydraulic power from the Yellow to the Green hydraulic system.
9.Simulate ENG1 N2>min idle
On panel 85VU:
  • On connector 1KS1-A, use a shunt to connect pins B2E and C28 together to simulate ENG1 running.

Simulate ENG2 N2>min idle
On panel 86VU:
  • On connector 1KS2-A, use a shunt to connect pins B2E and C28 together to simulate ENG2 running.
On panel 40VU:
  • The OFF legend of the P/BSW is off
  • The FAULT legend of the P/BSW is off.
On the ECAM lower DU:
  • Check that the PTU supplies hydraulic power from the Yellow to the Green hydraulic system.
10.Simulate ADIRU-2<50kts
  • On ADIRU-2 (1FP2), remove the ground from connector AA, pin 2G.

Simulate ADIRU-3<50kts
  • On ADIRU-3 (1FP3), remove the ground from connector AA, pin 2G.
On panel 40VU:
  • The OFF legend of the P/BSW is off
  • The FAULT legend of the P/BSW is off.
On the ECAM lower DU:
  • Check that the PTU is inhibited.
5. Close-up
Subtask 29-23-00-420-052-A ** ON A/C NOT FOR ALL
A. Installation of the removed components
   (1) On panel 85VU, remove the shunt between pins B2E and C28 of connector 1KS1-A (simulation of ENG1 N2<min idle).
   (2) On panel 86VU, remove the shunt between pins B2E and C28 of connector 1KS2-A (simulation of ENG2 N2<min idle).
Subtask 29-23-00-860-078-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) In the cockpit, set the ENG1 and ENG 2 Master Switches to the OFF position.
Subtask 29-23-00-420-054-A ** ON A/C NOT FOR ALL
C. Installation of the removed components
   (1) Install the Engine Interface Units (EIUs):
     (a) Install the EIU (1KS1) (Ref. AMM TASK 73-25-34-400-803).
     (b) Install the EIU (1KS2) (Ref. AMM TASK 73-25-34-400-803).
Subtask 29-23-00-865-085-A ** ON A/C NOT FOR ALL
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
49VUENGINE/1 AND 2/IGN/SYS A1JHA03
** ON A/C NOT FOR ALL
121VUENGINE/ENG2/FADEC B/AND EIU24KS2Q40
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
** ON A/C NOT FOR ALL
121VUENGINE/IGN/ENG2/SYS B3JH2P42
121VUENGINE/IGN/ENG1/SYS B3JH1P41
** ON A/C NOT FOR ALL
121VUENGINE/ENG2/FADEC B/AND EIU24KS2R41
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R40
Subtask 29-23-00-860-073-A ** ON A/C NOT FOR ALL
E. Aircraft Maintenance Configuration
   (1) Make sure that the PTU operates (OFF and FAULT legends are off).
Subtask 29-23-00-865-086-A ** ON A/C NOT FOR ALL
F. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUHYDRAULIC/SOL VALVES/G/Y/PTU1801GLN34
121VUHYDRAULIC / PTU FLT INHIB1825GLQ31
Subtask 29-23-00-860-074-A ** ON A/C NOT FOR ALL
G. Aircraft Maintenance Configuration
   (1) On the overhead panel 40VU, set the PTU P/BSW to OFF.
   (2) Make sure that the OFF legend on the PTU P/BSW is on and the FAULT legend does not come on.
Subtask 29-23-00-865-087-A ** ON A/C NOT FOR ALL
H. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUHYDRAULIC/SOL VALVES/G/Y/PTU1801GLN34
121VUHYDRAULIC / PTU FLT INHIB1825GLQ31
Subtask 29-23-00-420-053-A ** ON A/C NOT FOR ALL
I. Installation of the ADIRU (1FP2, 1FP3)
   (1) Install the ADIRU-2 (1FP2) and the ADIRU-3 (1FP3) (Ref. AMM TASK 34-12-34-400-001).
Subtask 29-23-00-865-088-A ** ON A/C NOT FOR ALL
J. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUADIRS/ADIRU/2/115VAC4FP2N06
121VUADIRS/ADIRU/3/115VAC4FP3N05
Subtask 29-23-00-860-075-A ** ON A/C NOT FOR ALL
K. Aircraft Maintenance Configuration
   (1) On the HP manifold of the Green hydraulic system, connect flight-control pressure-switch electrical-connector 10CE2-A.
   (2) On LGCIU-2, remove the shunt from connector AA pin 9G.
   (3) On LGCIU-2, remove the shunt from connector AB pin 9A.
   (4) Install LGCIU-2 (5GA2) (Ref. AMM TASK 32-31-71-400-001).
Subtask 29-23-00-865-089-A ** ON A/C NOT FOR ALL
L. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB06
** ON A/C NOT FOR ALL
49VUL/G/LGCIU/SYS1/NORM1GAC09
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB01
** ON A/C NOT FOR ALL
121VULGCIU/BAT SPLY/SYS259GAR33
121VULGCIU/BAT SPLY/SYS158GAR32
** ON A/C NOT FOR ALL
121VUHYDRAULIC/LGCIU/SYS22GAQ35
121VUHYDRAULIC/LGCIU/SYS1/GRND SPLY52GAQ34
121VUFLIGHT CONTROLS/SLT/CTL/SYS27CVR21
** ON A/C NOT FOR ALL
121VULGCIU/BAT SPLY/SYS259GAR32
121VULGCIU/BAT SPLY/SYS158GAR31
Subtask 29-23-00-410-054-A ** ON A/C NOT FOR ALL
M. Close Access
   (1) Do the ground configuration after flight configuration with electrical power procedure (Ref. AMM TASK 32-00-00-860-002).
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) Close access panel 196BB (Ref. AMM TASK 53-35-13-400-002).
   (4) Close the main landing-gear doors (Ref. AMM TASK 32-12-00-410-001).
   (5) Remove the access platform(s).
   (6) Remove the WARNING NOTICE(S).
   (7) Remove the safety barrier(s).
Subtask 29-23-00-860-076-A ** ON A/C NOT FOR ALL
N. Put the aircraft back to the serviceable condition.
   (1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
   (2) In the cockpit, make sure that the parking brake is in the ON position.
   (3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:19:42 UTC