W DOC AIRBUS | AMM A320F

Remove Ram Air Turbine AGCM and Pump for for in Shop Functional Check


TASK 29-22-00-920-002-A
Remove Ram Air Turbine AGCM and Pump for for in Shop Functional Check


ZONE: 190
ZONE: 195
ZONE: 197
FIN: 2GE ** ON A/C NOT FOR ALL
1. Reason for the Job
Refer to the MPD TASK: 292000-06
REMOVE RAM AIR TURBINE AGCM AND PUMP FOR IN SHOP FUNCTIONAL CHECK.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
190
BELLY FAIR, AIR CONDITIONING & HYD COMPT
195
HYDRAULIC COMPT AND FAIRINGS
197
REAR FAIRING
3. Job Set-up
Subtask 29-22-00-860-093-A ** ON A/C NOT FOR ALL
A. There is no special job set-up for this task.
4. Procedure
Subtask 29-22-00-020-052-A ** ON A/C NOT FOR ALL
A. Removal of the Components
   (1) Remove the RAT ground check module (2027GE) (Ref. AMM D/O 29-22-52-00).
   (2) Remove the RAT hydraulic pump (Ref. AMM D/O 29-22-51-00).
Subtask 29-22-00-720-055-A ** ON A/C NOT FOR ALL
B. Functional Check of the Ground-check Module (2027GE) and the Hydraulic Pump
   (1) Send the RAT ground-check module (2027GE) and the hydraulic pump to the workshop.
Subtask 29-22-00-420-053-A ** ON A/C NOT FOR ALL
C. Installation of the Components
   (1) Install the RAT ground check module (2027GE) (Ref. AMM D/O 29-22-52-40).
   (2) Install the RAT hydraulic pump (Ref. AMM D/O 29-22-51-40).
[Rev.8 from Aug 2017] 2026.04.02 06:19:38 UTC