W DOC AIRBUS | AMM A320F

Removal and Installation to Inspect the Filter Element of the Ram Air Turbine and Cleaning Procedure of the Filter Element


TASK 29-22-00-920-001-A
Removal and Installation to Inspect the Filter Element of the Ram Air Turbine and Cleaning Procedure of the Filter Element


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
WARNING: MAKE SURE THAT THE RAT TRAVEL RANGE IS CLEAR BEFORE YOU EXTEND/RETRACT THE RAT.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
3. Job Set-up
Subtask 29-22-00-865-061-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUHYD/RAT/CTL2801GED14
106VUCSM/G /EV/MAN/SPLY6XEB04
121VUHYDRAULIC/RAT/SPLY/EXTN/SOL12803GEP33
4. Procedure
Subtask 29-22-00-130-051-B ** ON A/C NOT FOR ALL
A. Ultrasonic Cleaning Procedure of the Filter Element
   (1) Put the filter element into a bath of Non Aqueous Cleaner-General - - (Material No.08BAA9) to remove the grease.
   (2) Remove the filter element from the cleaning agent and examine it for damage. If it is damaged, discard the filter element.
   (3) Clean the filter element chemically or ultrasonically as written below.
   (4) For the ultrasonic cleaning procedure:
     (a) Clean the filter element ultrasonically. Refer to local regulations.
NOTE: Make sure that the open end of the filter element points down when you clean it.
   (5) After the cleaning procedure, continue to the pressure test.
5. Close-up
Subtask 29-22-00-865-062-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUHYD/RAT/CTL2801GED14
106VUCSM/G /EV/MAN/SPLY6XEB04
121VUHYDRAULIC/RAT/SPLY/EXTN/SOL12803GEP33
[Rev.10 from 2021] 2026.04.01 00:25:52 UTC