W DOC AIRBUS | AMM A320F

Installation of the Outlet Non-Return Valve of the Reservoir Pressurization Unit


TASK 29-14-41-400-003-A
Installation of the Outlet Non-Return Valve of the Reservoir Pressurization Unit


WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
CONTAINER 3 L(3/4 USGAL)
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft ) T
No specific
Torque wrench: range to between 1.9 and 1.7 m.daN (14.01 and 12.54 lbf.ft ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.02ABA1)
Phosphate Ester Hydraulic Fluid-General Power - -
(Material No.14CCB6)
Testing Medium-Leak Detection - Oxygen System
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 29-00-00-864-001-A
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
TASK 29-00-00-910-002-A
Safety Procedures of the Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
TASK 29-14-00-614-002-A
Pressurization of the Hydraulic Reservoirs through the Ground Connector
TASK 29-14-00-614-002-A-01
Pressurization of the Hydraulic Reservoirs with the Auxiliary Power Unit (APU)
TASK 36-12-00-710-001-A
Operational Test of the APU Bleed Air Supply and Crossbleed Systems
TASK 49-00-00-860-005-A
APU Start by External Power
TASK 49-00-00-860-005-A-01
APU Start by Batteries
TASK 49-00-00-860-006-A
APU Shutdown by External Power
TASK 49-00-00-860-006-A-01
APU Shutdown by Batteries
TASK 49-00-00-860-008-A
APU Start by External Power
TASK 49-00-00-860-008-A-01
APU Start by Batteries
TASK 49-00-00-860-009-A
APU Shutdown by External Power (131-9(A))
TASK 49-00-00-860-009-A-01
APU Shutdown by Batteries (131-9(A))
3. Job Set-up
Subtask 29-14-41-860-061-A
A. Aircraft Maintenance Configuration
WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES.
   (1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002).
   (2) Make sure that the hydraulic systems are depressurized and put them in the maintenance configuration
(Ref. AMM TASK 29-00-00-864-001).
   (3) Make sure that the reservoirs of the Green, Blue and Yellow hydraulic systems are depressurized (Ref. AMM TASK 29-14-00-614-001).
   (4) Make sure that the WARNING NOTICE(S) are in position to tell persons not to pressurize the Green, Blue and Yellow hydraulic systems:
  • in the cockpit on the hydraulic section 40VU of the overhead panel,
  • on the ground service panel of the Green, Blue and Yellow hydraulic systems.
   (5) Make sure that the access panel 195BB is open.
   (6) Make sure that the CONTAINER 3 L(3/4 USGAL) is in position below the reservoir pressurization unit.
Subtask 29-14-41-865-060-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
** ON A/C NOT FOR ALL
49VUHYDRAULIC/G HYD/PUMP ENG1/CTL1701GKH12
** ON A/C NOT FOR ALL
121VUHYDRAULIC/G HYD/PUMP ENG1/CTL1701GKR35
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN30
121VUHYDRAULIC/G HYD/PUMP ENG1/MONG1702GKR34
** ON A/C ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN31
121VUHYDRAULIC/G HYD/PUMP ENG1/MONG1702GKR33
** ON A/C ALL
123VUB HYD/ELEC PUMP2701GJAB09
123VUY HYD/ELEC/PUMP3802GXAB06
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
4. Procedure
Subtask 29-14-41-420-054-A
A. Installation of the Outlet Non-Return Valve of the Reservoir Pressurization Unit (1360GM)
CAUTION: USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT HYDRAULIC LINES ON UNIONS. IF YOU DO NOT USE THE SECOND WRENCH, THERE IS A RISK THAT YOU WILL LOOSEN OR TIGHTEN THE UNION TOO MUCH.
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Remove the blanking plug from the port of the reservoir pressurization unit (3).
   (4) Apply Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) to the threads and O-rings of the outlet non-return valve (2).
   (5) Install the outlet non-return valve (2) in the reservoir pressurization unit (3).
   (6) TORQUE the outlet non-return valve (2) to between 1.9 and 1.7 m.daN (14.01 and 12.54 lbf.ft ) T.
   (7) Remove the blanking plug from the line end (1).
   (8) Make sure that the line end-fitting is serviceable.
   (9) Apply Phosphate Ester Hydraulic Fluid-General Power - - (Material No.
02ABA1) to the threads of the line end-fitting.
   (10) Connect the line (1) to the outlet non-return valve (2).
   (11) TORQUE the union nut of the line (1) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft ) T.
Subtask 29-14-41-865-061-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
** ON A/C NOT FOR ALL
49VUHYDRAULIC/G HYD/PUMP ENG1/CTL1701GKH12
** ON A/C NOT FOR ALL
121VUHYDRAULIC/G HYD/PUMP ENG1/CTL1701GKR35
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN30
121VUHYDRAULIC/G HYD/PUMP ENG1/MONG1702GKR34
** ON A/C ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN31
121VUHYDRAULIC/G HYD/PUMP ENG1/MONG1702GKR33
** ON A/C ALL
123VUB HYD/ELEC PUMP2701GJAB09
123VUY HYD/ELEC/PUMP3802GXAB06
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
Subtask 29-14-41-790-055-A
C. Test of the Outlet Non-Return Valve
NOTE: Do a leak test on the outlet non-return valve (2) with the air pressure supplied from both a ground supply and the low pressure air bleed. Do the test at the same time as the pressure is supplied.
   (1) Start the aircraft APU (
Ref. AMM D/O 49-00-00-86) or
(Ref. AMM TASK 49-00-00-860-005) or
(Ref. AMM TASK 49-00-00-860-008).
   (2) Make sure that the bleed air supply from the APU is set to supply the reservoir pressurizing system (Ref. AMM TASK 36-12-00-710-001).
   (3) Apply Testing Medium-Leak Detection - Oxygen System (Material No.14CCB6) to the these connections:
  • The line (1) and the outlet non-return valve (2),
  • the reservoir pressurization unit (3) and the outlet non-return valve (2).
   (4) Make sure that there is no leak.
   (5) Stop the operation of the aircraft APU (Ref. AMM D/O 49-00-00-86).
(Ref. AMM TASK 49-00-00-860-006) or
(Ref. AMM TASK 49-00-00-860-009).
   (6) Pressurize the reservoirs of the Green, Blue and Yellow hydraulic systems (Ref. AMM TASK 29-14-00-614-002).
   (7) Examine these connections and make sure that there is no leak:
  • The line (1) and the outlet non-return valve (2),
  • the reservoir pressurization unit (3) and the outlet non-return valve (2).
5. Close-up
Subtask 29-14-41-860-062-A
A. Put the aircraft back to the serviceable condition.
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the container.
   (3) Remove the warning notices from the cockpit and the ground service panels.
   (4) Close the access panel 195BB.