W DOC AIRBUS | AMM A320F

Removal of the Reservoir Depressurization Valve of the Blue Hydraulic System


TASK 29-14-16-000-002-A
Removal of the Reservoir Depressurization Valve of the Blue Hydraulic System


WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
FIN: 2087GM
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
CAP - BLANKING
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
2
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
197EB
197BB
197KB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 29-00-00-864-001-A
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
TASK 29-00-00-910-002-A
Safety Procedures of the Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
TASK 53-35-13-000-002-A
Removal of the Quick-Release Access Panels from the Belly Fairing Structure
3. Job Set-up
Subtask 29-14-16-865-052-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
121VUHYDRAULIC/LOW/LVL/IND1832GQN32
121VUHYDRAULIC/HYD/QTY/IND1831GQP35
123VUB HYD/ELEC PUMP2701GJAB09
Subtask 29-14-16-860-051-A
B. Aircraft Maintenance Configuration
WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES.
   (1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002).
   (2) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the Blue hydraulic system:
  • In the cockpit on the hydraulic panel 40VU of the overhead panel,
  • On the ground service panel of the Blue hydraulic system.
   (3) Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration.
(Ref. AMM TASK 29-00-00-864-001).
   (4) Depressurize the reservoir of the Blue hydraulic system (Ref. AMM TASK 29-14-00-614-001).
Subtask 29-14-16-010-051-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the access door 197EB.
   (2) Remove the access panel 197BB (Ref. AMM TASK 53-35-13-000-002).
Subtask 29-14-16-010-051-B ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the access door 197EB.
   (2) Remove the access panel 197KB (Ref. AMM TASK 53-35-13-000-002).
4. Procedure
Subtask 29-14-16-020-051-A
A. Removal of the Reservoir Depressurization Valve
CAUTION: USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT HYDRAULIC LINES ON UNIONS. IF YOU DO NOT USE THE SECOND WRENCH, THERE IS A RISK THAT YOU WILL LOOSEN OR TIGHTEN THE UNION TOO MUCH.
   (1) Hold the reducer (2) and disconnect the line end-fitting (1) from the reducer (2).
   (2) Install the CAP - BLANKING on the disconnected line ends.
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
   (3) Cut and remove the lockwire which safeties the cap assembly.
   (4) Remove the parts which are attached to the removed depressurization valve as follows:
     (a) Hold the depressurization valve (4) and remove the reducer (2).
     (b) Remove and discard the O-ring (3).
     (c) Put a PLUG - BLANKING on the reducer (2) and the depressurization valve (4).
   (5) Remove the nuts (6) and the bolts (5).
   (6) Remove the depressurization valve (4) from the ground service panel.
[Rev.10 from 2021] 2026.04.01 00:24:34 UTC