W DOC AIRBUS | AMM A320F

Installation of the Bleed-Air Line Restrictor


TASK 29-14-13-400-001-A
Installation of the Bleed-Air Line Restrictor


FIN: 1392GM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft ) T
No specific
Torque wrench: range to between 3.2 and 2.9 m.daN (23.60 and 21.39 lbf.ft ) T
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
195BB
476BR, 476CR
475BR
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
10
PACKING
AIPC 29-14-06-01-130
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 29-10-00-864-003-A
Depressurize the Blue Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
TASK 29-23-00-864-001-A
Depressurize the Green and Yellow Hydraulic Systems after Operation of the PTU
TASK 29-24-00-864-001-A
Depressurize the Yellow Hydraulic System
TASK 54-53-11-000-002-A
Removal of the Pylon-to-Wing Access Panels
TASK 54-53-11-000-002-B
Removal of the Pylon-to-Wing Access Panels
TASK 54-53-11-400-002-A
Installation of the Pylon-to-Wing Access Panels
TASK 54-53-11-400-002-B
Installation of the Pylon-to-Wing Access Panels
F Bleed-Air Line Restrictor ** ON A/C NOT FOR ALL
F Bleed-Air line Restrictor ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 29-14-13-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the hydraulic system are depressurized (Ref. AMM TASK 29-23-00-864-001) (Ref. AMM TASK 29-24-00-864-001) (Ref. AMM TASK 29-10-00-864-003).
   (2) Make sure that the hydraulic reservoir is depressurized (Ref. AMM TASK 29-14-00-614-001).
   (3) Make sure that WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the hydraulic system:
  • on the ground service panel 198CB.
   (4) Make sure that WARNING NOTICE(S) is (are) in position on the access door 195BB to tell persons not to pressurize the hydraulic reservoir.
   (5) Make sure that an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the zone 476.
   (6) Make sure that the access panels 476BR, 476CR are removed (Ref. AMM TASK 54-53-11-000-002).
Subtask 29-14-13-860-051-C ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the hydraulic system are depressurized (Ref. AMM TASK 29-23-00-864-001) (Ref. AMM TASK 29-24-00-864-001) (Ref. AMM TASK 29-10-00-864-003).
   (2) Make sure that the hydraulic reservoir is depressurized (Ref. AMM TASK 29-14-00-614-001).
   (3) Make sure that WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the hydraulic system:
  • on the ground service panel 198CB.
   (4) Make sure that WARNING NOTICE(S) is (are) in position on the access door 195BB to tell persons not to pressurize the hydraulic reservoir.
   (5) Make sure that an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the zone 476.
   (6) Make sure that the access panel 475BR is removed (Ref. AMM TASK 54-53-11-000-002).
Subtask 29-14-13-941-052-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
  • make sure that WARNING NOTICE(S) is (are) in position to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the hydraulic system:
  • in the cockpit, on the HYD section of the overhead panel 40VU.
   (4) On the overhead maintenance panel 50VU:
  • make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
   (5) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to energize the FADEC 1(2).
4. Procedure
Subtask 29-14-13-420-051-A ** ON A/C NOT FOR ALL 5. Close-up
Subtask 29-14-13-410-050-A ** ON A/C NOT FOR ALL
Subtask 29-14-13-410-050-C ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Remove the WARNING NOTICE(S).
   (2) Remove the access platform(s).
   (3) Make sure that the work area is clean and clear of tools and other items.
   (4) Install the access panel 475BR (Ref. AMM TASK 54-53-11-400-002).
   (5) Close the door 195BB.
[Rev.10 from 2021] 2026.04.01 00:24:15 UTC