W DOC AIRBUS | AMM A320F

Inspection of the Engine Pump Fire-Valve


TASK 29-13-52-200-001-A
Inspection of the Engine Pump Fire-Valve


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
FIN: 3046GD
1. Reason for the Job
To make a visual inspection of the fire valve 3046GD.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 3M (10 FT)
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
674AB
 C. Referenced Information
REFERENCE
DESIGNATION
3. Job Set-up
Subtask 29-13-52-941-055-A
A. Safety Precautions
   (1) Put the SAFETY BARRIER(S)S in position.
   (2) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the hydraulic systems.
Subtask 29-13-52-865-053-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/FIRE VALVE/Y/ENG23702GDC14
121VUHYDRAULIC/Y HYD/PUMP ENG2/MONG3700GDQ37
Subtask 29-13-52-010-052-A
C. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT) below zone 674.
   (2) Remove the access panel 674AB.
4. Procedure
Subtask 29-13-52-210-052-A
A. Inspection of the Engine Pump Fire-Valve
   (1) Examine the engine pump fire-valve 3046GD for damage, corrosion and signs of leakage.
   (2) Make an inspection of the line end fittings and electrical connector. Make sure they are correct and satisfactory.
5. Close-up
Subtask 29-13-52-410-051-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the access panel 674AB.
Subtask 29-13-52-865-054-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/FIRE VALVE/Y/ENG23702GDC14
121VUHYDRAULIC/Y HYD/PUMP ENG2/MONG3700GDQ37
Subtask 29-13-52-942-052-A
C. Removal of Equipment
   (1) Remove the SAFETY BARRIER(S)S.
   (2) Remove the WARNING NOTICE(S).
   (3) Remove the access platform(s).
   (4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
[Rev.10 from 2021] 2026.04.01 00:23:59 UTC