Installation of the Engine-Pump Case-Drain Filter Differential-Pressure Indicator
TASK 29-13-43-400-806-A
Installation of the Engine-Pump Case-Drain Filter Differential-Pressure Indicator
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 29-13-43-860-076-A ** ON A/C NOT FOR ALL
Subtask 29-13-43-420-061-A ** ON A/C NOT FOR ALL
Subtask 29-13-43-942-066-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:21:31 UTC
Installation of the Engine-Pump Case-Drain Filter Differential-Pressure Indicator
WARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
WARNING:
DO NOT TOUCH THE HYDRAULIC SYSTEM COMPONENTS FOR A SHORT TIME AFTER THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS STAY HOT FOR SOME TIME AND CAN CAUSE INJURY.
CAUTION:
DO NOT LET HYDRAULIC FLUID FALL ON THE ENGINE. UNWANTED HYDRAULIC FLUID MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH. THE FLUID CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
ZONE: 440
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | CONTAINER 5 L (1.32 USGAL) |
| No specific | AR | WARNING NOTICE(S) |
| No specific | Torque wrench: range to between 14.7 and 12.5 m.N (130.09 and 110.62 lbf.in ) ![]() |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.02ABA1) | Phosphate Ester Hydraulic Fluid-General Power - - |
| (Material No.14QMC1) | Wire-Locking Dia: 0.9 mm CRES - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 440 | ENG 2 AIR INTAKE, FAN AND ACCESS GEARBOX |
| 196BB, 198CB, 447AL |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 20 | RING | AIPC 29-13-43-02-060 |
| 30 | PACKING | AIPC 29-13-43-02-070 |
| 30 | PACKING | AIPC 29-13-43-02-080 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 29-10-00-864-002-A | Depressurize the Yellow Hydraulic System |
| TASK 29-13-00-710-002-A | Operational Test of the Yellow Hydraulic System |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
Subtask 29-13-43-860-076-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the Yellow hydraulic system is depressurized (Ref. AMM TASK 29-10-00-864-002).
(2) Make sure that the Yellow hydraulic reservoir is depressurized (Ref. AMM TASK 29-14-00-614-001).
(3) On ground service-panel door of the Yellow hydraulic system 198CB:
Subtask 29-13-43-010-073-A ** ON A/C NOT FOR ALL Subtask 29-13-43-941-077-A ** ON A/C NOT FOR ALL (1) Make sure that the Yellow hydraulic system is depressurized (Ref. AMM TASK 29-10-00-864-002).
(2) Make sure that the Yellow hydraulic reservoir is depressurized (Ref. AMM TASK 29-14-00-614-001).
(3) On ground service-panel door of the Yellow hydraulic system 198CB:
- Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the Yellow hydraulic system.
- Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the Yellow hydraulic reservoir.
C. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(3) In the cockpit, on the HYD section of overhead panel 40VU:
4. Procedure(1) On the center pedestal, on ENG panel 115VU:
- Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to start the engine.
(3) In the cockpit, on the HYD section of overhead panel 40VU:
- Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the Yellow hydraulic system.
- Make sure that the ON legend of the ENG/FADEC GND PWR/(1)2 pushbutton switch is off.
- Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to energize the FADEC (1)2.
Subtask 29-13-43-420-061-A ** ON A/C NOT FOR ALL
A. Installation of the Engine-Pump Case-Drain Filter Differential-Pressure Indicator
(1) Remove the blanking cover from the engine-pump case-drain filter differential-pressure indicator port.
(2) Install the ring (20) and the packings (30):
(b) Lubricate the AIPC 29-13-43-02-070 PACKING (30) and the AIPC 29-13-43-02-080 PACKING (30) with Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) .
(c) Put the packings (30) on the engine-pump case-drain filter differential-pressure indicator (10).
(d) Install the engine-pump case-drain filter differential-pressure indicator (10) in the filter head port.
(e) TORQUE the engine-pump case-drain filter differential-pressure indicator (10) to between 14.7 and 12.5 m.N (130.09 and 110.62 lbf.in )
.
14QMC1 Wire-Locking Dia: 0.9 mm CRES - , safety the engine-pump case-drain filter differential-pressure indicator (10) to the filter head.
Subtask 29-13-43-710-064-A ** ON A/C NOT FOR ALL (1) Remove the blanking cover from the engine-pump case-drain filter differential-pressure indicator port.
(2) Install the ring (20) and the packings (30):
CAUTION:
RING (20) IS FITTED AT THE NEAREST POSITION TO THE HEXHEAD.
CAUTION:
USE A NEW RING (20) AND PACKINGS (30) WHEN FITTING THE DIFFERENTIAL PRESSURE INDICATOR (10) IN THE FILTER MODULE PORT.
(a) Put the AIPC 29-13-43-02-060 RING (20) on the engine-pump case-drain filter differential-pressure indicator (10).(b) Lubricate the AIPC 29-13-43-02-070 PACKING (30) and the AIPC 29-13-43-02-080 PACKING (30) with Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) .
(c) Put the packings (30) on the engine-pump case-drain filter differential-pressure indicator (10).
(d) Install the engine-pump case-drain filter differential-pressure indicator (10) in the filter head port.
(e) TORQUE the engine-pump case-drain filter differential-pressure indicator (10) to between 14.7 and 12.5 m.N (130.09 and 110.62 lbf.in )
.WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(f) With the B. Operational Test
(1) Do the operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
(2) During the dry-motoring of the Engine 2, make sure that:
5. Close-up(1) Do the operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
(2) During the dry-motoring of the Engine 2, make sure that:
- There are no leaks from the engine-pump case-drain filter differential-pressure indicator
- The engine-pump case-drain filter differential-pressure indicator is not extended.
Subtask 29-13-43-942-066-A ** ON A/C NOT FOR ALL
A. Remove the safety precautions
(1) Remove the WARNING NOTICE(S).
(2) Remove the container.
(3) Make sure that the work area is clean and clear of tools and other items.
Subtask 29-13-43-410-069-A ** ON A/C NOT FOR ALL (1) Remove the WARNING NOTICE(S).
(2) Remove the container.
(3) Make sure that the work area is clean and clear of tools and other items.
Engine-Pump Case-Drain Filter Differential-Pressure Indicator