W DOC AIRBUS | AMM A320F

Installation of the Engine-Pump Case-Drain Filter


TASK 29-13-43-400-040-A
Installation of the Engine-Pump Case-Drain Filter


WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES.
WARNING: DO NOT TOUCH THE HYDRAULIC SYSTEM COMPONENTS FOR A SHORT TIME AFTER THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS STAY HOT FOR SOME TIME AND CAN CAUSE INJURY.
CAUTION: DO NOT LET HYDRAULIC FLUID FALL ON THE ENGINE. UNWANTED HYDRAULIC FLUID MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH. THE FLUID CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
FIN: 3084GM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CONTAINER 5 L (1.32 USGAL)
No specific
AR
WARNING NOTICE(S)
No specific
1
WRENCH - TORQUE
No specific
Torque wrench: range to between 245 and 215 lbf.in (2.77 and 2.43 m.daN ) T
No specific
Torque wrench: range to between 0.79 and 0.56 m.daN (69.91 and 49.56 lbf.in ) T
No specific
Torque wrench: range to between 2.26 and 2.03 m.daN (16.67 and 14.97 lbf.ft ) T
No specific
Torque wrench: range to between 2.76 and 2.42 m.daN (20.35 and 17.85 lbf.ft ) T
No specific
Torque wrench: range to between 3.39 and 2.82 m.daN (25.00 and 20.80 lbf.ft ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.02ABA1)
Phosphate Ester Hydraulic Fluid-General Power - -
(Material No.14QFB1)
Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
195BB
FOR [1000EM2] (ENGINE-2)
447AL
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
25
PACKING
AIPC 29-13-43-01-020
7
PACKING
AIPC 29-13-43-01-020
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 12-12-29-611-001-A
Fill the Hydraulic Fluid Reservoir with a Hand Pump
TASK 29-10-00-864-002-A
Depressurize the Yellow Hydraulic System
TASK 29-13-00-710-002-A
Operational Test of the Yellow Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
TASK 29-14-00-614-002-A
Pressurization of the Hydraulic Reservoirs through the Ground Connector
TASK 29-14-00-614-002-A-01
Pressurization of the Hydraulic Reservoirs with the Auxiliary Power Unit (APU)
FOR [1000EM2] (ENGINE-2)
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
3. Job Set-up
Subtask 29-13-43-860-053-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the Yellow hydraulic system is depressurized (Ref. AMM TASK 29-10-00-864-002).
   (2) Make sure that the Yellow hydraulic reservoir is depressurized (Ref. AMM TASK 29-14-00-614-001).
   (3) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the Yellow hydraulic system:
  • on the ground service panel 198CB.
   (4) Make sure that the WARNING NOTICE(S) is (are) in position on the access door 195BB to tell persons not to pressurize the Yellow hydraulic reservoir.
   (5) Make sure that an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the engine 1(2).
   (6) Make sure that the fan-cowl door is open.
Subtask 29-13-43-941-057-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
  • make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the Yellow hydraulic system:
  • in the cockpit, on the HYD section of the overhead panel 40VU.
   (4) On the overhead maintenance panel 50VU:
  • make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
   (5) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to energize the FADEC 1(2).
   (6) Make sure that a CONTAINER 5 L (1.32 USGAL) is below the case drain upper and lower hose connections to the hydraulic pump case drain filter module (5) to collect the remaining fluid.
4. Procedure
Subtask 29-13-43-420-051-A ** ON A/C NOT FOR ALL Subtask 29-13-43-420-052-A ** ON A/C NOT FOR ALL
B. Installation of the Case Drain Filter
AFTER SB RA32029-5
   (1) Remove the blanking covers from the ports of the filter module (5), the union (10) and the elbow (35).
   (2) Lubricate the
AIPC 29-13-43-01-020 PACKING (7) with Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) and put them on the unions (10). Install the union (10) in the port at the top of the filter module.
   (3) TORQUE the union (10) to between 3.39 and 2.82 m.daN (25.00 and 20.80 lbf.ft ) T.
   (4) Lubricate the
AIPC 29-13-43-01-020 PACKING (25) with Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) . Install the packing (25), the nut (30) and the elbow (35) in the port of the filter module.
   (5) TORQUE the nut (30) and elbow (35) on the filter module to between 2.26 and 2.03 m.daN (16.67 and 14.97 lbf.ft ) T.
   (6) Attach the filter module (5) to the filter support bracket with the four bolts (15) and the washers (20).
   (7) TORQUE the bolts (15) to between 0.79 and 0.56 m.daN (69.91 and 49.56 lbf.in )
T.
   (8) Safety the two left filter-module mount bolts (15) with 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
   (9) Safety the filter element case with lockwire to the two right filter-module mount bolts (15).
   (10) Remove the blanking covers from the case drain upper and lower hose couplings and the filter module unions (10).
   (11) Connect the case drain upper hose to the union (10) on the filter module.
   (12) TORQUE the upper hose coupling nuts to between 2.76 and 2.42 m.daN (20.35 and 17.85 lbf.ft )
T.
   (13) Connect the case drain lower hose to the elbow (35) on the filter module.
   (14) TORQUE the lower hose coupling nuts to between 245 and 215 lbf.in (2.77 and 2.43 m.daN )
T.
NOTE: Use a second WRENCH - TORQUE to hold the fittings when you torque the coupling nuts. This prevents damage to the hose.
Subtask 29-13-43-710-055-A ** ON A/C NOT FOR ALL
C. Operational Test
   (1) Pressurize the Yellow hydraulic reservoir (
Ref. AMM TASK 29-14-00-614-002).
   (2) Do an operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
   (3) During the dry motoring of the engine 2, make sure that:
  • there are no leaks from the case drain filter,
  • the clogging indicator of the filter is not out.
   (4) Make sure that the level of the hydraulic fluid in the Yellow reservoir is correct. If necessary, fill the reservoir (Ref. AMM TASK 12-12-29-611-001).
5. Close-up
Subtask 29-13-43-410-055-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Remove the WARNING NOTICE(S).
   (2) Remove the access platform(s).
   (3) Make sure that the work area is clean and clear of tools and other items.
   (4) Close the left fan cowl door
     (a) FOR [1000EM2] (ENGINE-2)
close the door 447AL (Ref. AMM TASK 71-13-00-410-040).
   (5) Close the door 195BB.
[Rev.10 from 2021] 2026.04.01 00:21:27 UTC