W DOC AIRBUS | AMM A320F

Installation of the Engine-Pump Pressure Switch


TASK 29-13-17-400-040-A
Installation of the Engine-Pump Pressure Switch


WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES.
WARNING: DO NOT TOUCH THE HYDRAULIC SYSTEM COMPONENTS FOR A SHORT TIME AFTER THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS STAY HOT FOR SOME TIME AND CAN CAUSE INJURY.
CAUTION: DO NOT LET HYDRAULIC FLUID FALL ON THE ENGINE. UNWANTED HYDRAULIC FLUID MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH. THE FLUID CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
FIN: 3074GD ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
1
CONTAINER 5 L (1.32 USGAL)
No specific
AR
WARNING NOTICE(S)
No specific
1
WRENCH - STANDARD
No specific
Torque wrench: range to between 25 and 20 lbf.in (0.28 and 0.23 m.daN ) T
No specific
Torque wrench: range to between 36 and 32 lbf.in (0.41 and 0.36 m.daN ) T
No specific
Torque wrench: range to between 405 and 380 lbf.in (4.58 and 4.29 m.daN ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.02ABA1)
Phosphate Ester Hydraulic Fluid-General Power - -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
447AL
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
3
PACKING
AIPC 29-13-17-01-060
8
PACKING
AIPC 29-13-17-01-060
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 12-12-29-611-001-A
Fill the Hydraulic Fluid Reservoir with a Hand Pump
TASK 29-10-00-864-002-A
Depressurize the Yellow Hydraulic System
TASK 29-13-00-710-002-A
Operational Test of the Yellow Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
TASK 29-14-00-614-002-A
Pressurization of the Hydraulic Reservoirs through the Ground Connector
TASK 29-14-00-614-002-A-01
Pressurization of the Hydraulic Reservoirs with the Auxiliary Power Unit (APU)
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
3. Job Set-up
Subtask 29-13-17-860-053-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the Yellow hydraulic system is depressurized (Ref. AMM TASK 29-10-00-864-002).
   (2) Make sure that the Yellow hydraulic reservoir is depressurized (Ref. AMM TASK 29-14-00-614-001).
   (3) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the Yellow hydraulic system:
  • On the ground service panel 198CB.
   (4) Make sure that the WARNING NOTICE(S) is (are) in position on the access door 195BB to tell persons not to pressurize the Yellow hydraulic reservoir.
   (5) Make sure that an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the engine.
   (6) Make sure that the fan cowl door 447AL is open (Ref. AMM TASK 71-13-00-010-040).
Subtask 29-13-17-941-055-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
  • Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
   (3) In the cockpit, on the HYD section of overhead panel 40VU:
  • Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the Yellow hydraulic system.
   (4) On overhead maintenance panel 50VU:
  • Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
   (5) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to energize FADEC 1(2).
   (6) Make sure that the CONTAINER 5 L (1.32 USGAL) is below the hydraulic tube connection of the pressure switch to collect the hydraulic fluid.
Subtask 29-13-17-865-051-A ** ON A/C NOT FOR ALL
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUHYDRAULIC/Y HYD/PUMP ENG2/MONG3700GDQ37
4. Procedure
Subtask 29-13-17-420-053-A ** ON A/C NOT FOR ALL Subtask 29-13-17-420-051-A ** ON A/C NOT FOR ALL Subtask 29-13-17-865-052-A ** ON A/C NOT FOR ALL
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUHYDRAULIC/Y HYD/PUMP ENG2/MONG3700GDQ37
Subtask 29-13-17-710-051-A ** ON A/C NOT FOR ALL
D. Operational Test
   (1) Pressurize the Yellow hydraulic reservoir (
Ref. AMM TASK 29-14-00-614-002).
   (2) Do an operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
   (3) During the dry motoring, make sure that there are no leaks from the LP pressure switch of the Yellow pump.
   (4) Make sure that the level of hydraulic fluid in the Yellow reservoir is correct. Fill the reservoir if necessary (Ref. AMM TASK 12-12-29-611-001).
5. Close-up
Subtask 29-13-17-942-051-A ** ON A/C NOT FOR ALL
A. Remove the Safety Precautions
   (1) Remove the WARNING NOTICE(S).
   (2) Remove the access platform(s).
   (3) Make sure that the work area is clean and clear of tools and other items.
Subtask 29-13-17-410-051-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Close the left fan-cowl door 447AL (Ref. AMM TASK 71-13-00-410-040).
   (2) Close the door 195BB.
[Rev.10 from 2021] 2026.04.01 00:19:59 UTC