W DOC AIRBUS | AMM A320F

Installation of the Reservoir Drain Valve


TASK 29-12-35-400-001-A
Installation of the Reservoir Drain Valve


WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
FIN: 2264GM
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
CONTAINER - HYDRAULIC FLUID RESISTANT
No specific
2
WARNING NOTICE(S)
No specific
Torque wrench: range to between 5.14 and 5.03 m.daN (37.91 and 37.09 lbf.ft ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.02ABA1)
Phosphate Ester Hydraulic Fluid-General Power - -
No specific
lockwire 0.8 mm (0.032 in.)
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
197EB
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
2
O-RING
AIPC 29-12-04-11-260
2
O-RING
AIPC 29-12-84-08-420
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 12-12-29-611-001-A
Fill the Hydraulic Fluid Reservoir with a Hand Pump
TASK 29-00-00-864-001-A
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
TASK 29-00-00-910-002-A
Safety Procedures of the Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
TASK 29-14-00-614-002-A
Pressurization of the Hydraulic Reservoirs through the Ground Connector
TASK 29-14-00-614-002-A-01
Pressurization of the Hydraulic Reservoirs with the Auxiliary Power Unit (APU)
3. Job Set-up
Subtask 29-12-35-860-051-A
A. Aircraft Maintenance Configuration
WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES.
   (1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002).
   (2) Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration.
(Ref. AMM TASK 29-00-00-864-001).
   (3) Make sure that the reservoir of the Blue hydraulic system is depressurized.
(Ref. AMM TASK 29-14-00-614-001).
   (4) Make sure that the access panel 197EB is open.
   (5) Make sure that the CONTAINER - HYDRAULIC FLUID RESISTANT is in position.
   (6) Make sure that the WARNING NOTICE(S) are in position to tell persons not to pressurize the Blue hydraulic system:
  • in the cockpit on the hydraulic section 40VU of the overhead panel,
  • on the ground service panel of the Blue hydraulic system.
Subtask 29-12-35-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
123VUB HYD/ELEC PUMP2701GJAB09
4. Procedure
Subtask 29-12-35-420-050-A
A. Installation of the Reservoir Drain Valve
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Remove the blanking plug from the adaptor (3).
   (4) Remove the blanking plug or the blanking cap from the reservoir drain valve (1).
   (5) Apply Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) to the threads of the adaptor (3) and to the AIPC 29-12-04-11-260 O-RING (2) or AIPC 29-12-84-08-420 O-RING (2).
   (6) Install the reservoir drain valve (1).
   (7) TORQUE the reservoir drain valve (1) to between 5.14 and 5.03 m.daN (37.91 and 37.09 lbf.ft )
T.
   (8) Safety the reservoir drain valve (1) with lockwire 0.8 mm (0.032 in.).
Subtask 29-12-35-790-050-A
B. Test
   (1) Pressurize the reservoir of the Blue hydraulic system (
Ref. AMM TASK 29-14-00-614-002).
   (2) Make sure that fluid level in the reservoir of the Blue hydraulic system is correct. Add fluid as necessary (Ref. AMM TASK 12-12-29-611-001).
   (3) Make sure that there are no leaks from the connection of the reservoir drain valve (1) and the adapter (3).
5. Close-up
Subtask 29-12-35-942-050-A
A. Put the aircraft back to the serviceable condition.
   (1) Remove the container.
   (2) Remove the warning notices from the cockpit and the ground service panel.
Subtask 29-12-35-410-050-A
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access door 197EB.
Subtask 29-12-35-865-052-A
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
123VUB HYD/ELEC PUMP2701GJAB09
[Rev.10 from 2021] 2026.04.01 00:19:09 UTC