Removal of the Reservoir Drain Valve
TASK 29-12-35-000-001-A
Removal of the Reservoir Drain Valve
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 29-12-35-865-050-A
Subtask 29-12-35-020-050-A
[Rev.10 from 2021]
2026.04.01 00:19:09 UTC
Removal of the Reservoir Drain Valve
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
FIN: 2264GM
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | CONTAINER - HYDRAULIC FLUID RESISTANT |
| No specific | 2 | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 2 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 197EB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 29-00-00-864-001-A | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
| TASK 29-00-00-910-002-A | Safety Procedures of the Hydraulic System |
| TASK 29-10-00-680-003-A | Drainage of the Reservoir of the Blue Hydraulic System |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
Subtask 29-12-35-865-050-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 29-12-35-860-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | HYD/HYD PWR/B WARN/& CTL | 2702GJ | C12 |
| 123VU | B HYD/ELEC PUMP | 2701GJ | AB09 |
B. Aircraft Maintenance Configuration
(2) Put WARNING NOTICE(S) in position to tell persons not to pressurize the Blue hydraulic system:
(Ref. AMM TASK 29-00-00-864-001).
(4) Depressurize the reservoir of the Blue hydraulic system (Ref. AMM TASK 29-14-00-614-001).
(5) Drain the reservoir of the Blue hydraulic system (Ref. AMM TASK 29-10-00-680-003).
(6) Put a CONTAINER - HYDRAULIC FLUID RESISTANT below the drain valve (2264GM).
Subtask 29-12-35-010-050-A 4. ProcedureWARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
(1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002). (2) Put WARNING NOTICE(S) in position to tell persons not to pressurize the Blue hydraulic system:
- in the cockpit on the hydraulic section 40VU of the overhead panel,
- on the ground service panel of the Blue hydraulic system.
(Ref. AMM TASK 29-00-00-864-001).
(4) Depressurize the reservoir of the Blue hydraulic system (Ref. AMM TASK 29-14-00-614-001).
(5) Drain the reservoir of the Blue hydraulic system (Ref. AMM TASK 29-10-00-680-003).
(6) Put a CONTAINER - HYDRAULIC FLUID RESISTANT below the drain valve (2264GM).
Subtask 29-12-35-020-050-A
A. Removal of the Reservoir Drain Valve
(1) Remove and discard the lockwire from the reservoir drain valve (1).
(2) Remove the reservoir drain valve (1) from the adaptor (3).
(3) Remove and discard the O-ring (2).
(4) Install a PLUG - BLANKING on the adaptor (3) and the reservoir drain valve (1).
(1) Remove and discard the lockwire from the reservoir drain valve (1).
(2) Remove the reservoir drain valve (1) from the adaptor (3).
(3) Remove and discard the O-ring (2).
(4) Install a PLUG - BLANKING on the adaptor (3) and the reservoir drain valve (1).
Reservoir Drain Valve