W DOC AIRBUS | AMM A320F

Removal of the Electric Pump Pressure-Switch


TASK 29-12-17-000-001-A
Removal of the Electric Pump Pressure-Switch


WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
FIN: 2074GJ
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
CAP - BLANKING
No specific
1
CONTAINER - HYDRAULIC FLUID RESISTANT
No specific
1
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
2
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
195BB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 29-00-00-864-001-A
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
TASK 29-00-00-910-002-A
Safety Procedures of the Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
F Electric Pump Pressure-Switch ** ON A/C NOT FOR ALL
F Electric Pump Pressure-Switch ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 29-12-17-865-051-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
123VUB HYD/ELEC PUMP2701GJAB09
Subtask 29-12-17-860-050-A
B. Aircraft Maintenance Configuration
WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES.
   (1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002).
   (2) Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration.
(Ref. AMM TASK 29-00-00-864-001).
   (3) Depressurize the reservoir of the Blue hydraulic system (Ref. AMM TASK 29-14-00-614-001).
   (4) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the Blue hydraulic system:
  • In the cockpit on the hydraulic section 40VU of the overhead panel,
  • On the ground service panel of the Blue system.
   (5) Put the CONTAINER - HYDRAULIC FLUID RESISTANT in position below the pressure switch to collect hydraulic fluid.
Subtask 29-12-17-010-051-A
C. Open the access panel 195BB.
4. Procedure
Subtask 29-12-17-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Electric Pump Pressure Switch
   (1) Disconnect the electrical connector (1).
   (2) Put a CAP - BLANKING on the disconnected electrical connector.
   (3) Cut and remove the lockwire.
   (4) Loosen the pressure switch (2) and remove it together with the O-ring (3) from the T-fitting (4).
   (5) Discard the O-ring.
   (6) Install the PLUG - BLANKING in the open ports.
Subtask 29-12-17-020-051-B ** ON A/C NOT FOR ALL
A. Removal of the Electric Pump Pressure-Switch
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
   (1) Disconnect the electrical connector (4).
   (2) Put a CAP - BLANKING on the disconnected electrical connector.
   (3) Cut and remove the lockwire.
   (4) Loosen the pressure switch (3) and remove it together with the O-ring (2) from the switch manifold (1).
   (5) Discard the O-ring (2).
   (6) Install the PLUG - BLANKING in the open ports.