Removal of the Electric Pump Pressure-Switch
TASK 29-12-17-000-001-A
Removal of the Electric Pump Pressure-Switch
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 29-12-17-865-051-A
Subtask 29-12-17-020-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:18:55 UTC
Removal of the Electric Pump Pressure-Switch
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
FIN: 2074GJ
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | CAP - BLANKING |
| No specific | 1 | CONTAINER - HYDRAULIC FLUID RESISTANT |
| No specific | 1 | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 2 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 195BB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 29-00-00-864-001-A | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
| TASK 29-00-00-910-002-A | Safety Procedures of the Hydraulic System |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
Subtask 29-12-17-865-051-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 29-12-17-860-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | HYD/HYD PWR/B WARN/& CTL | 2702GJ | C12 |
| 123VU | B HYD/ELEC PUMP | 2701GJ | AB09 |
B. Aircraft Maintenance Configuration
(2) Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration.
(Ref. AMM TASK 29-00-00-864-001).
(3) Depressurize the reservoir of the Blue hydraulic system (Ref. AMM TASK 29-14-00-614-001).
(4) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the Blue hydraulic system:
Subtask 29-12-17-010-051-A 4. ProcedureWARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
(1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002). (2) Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration.
(Ref. AMM TASK 29-00-00-864-001).
(3) Depressurize the reservoir of the Blue hydraulic system (Ref. AMM TASK 29-14-00-614-001).
(4) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the Blue hydraulic system:
- In the cockpit on the hydraulic section 40VU of the overhead panel,
- On the ground service panel of the Blue system.
Subtask 29-12-17-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Electric Pump Pressure Switch
(1) Disconnect the electrical connector (1).
(2) Put a CAP - BLANKING on the disconnected electrical connector.
(3) Cut and remove the lockwire.
(4) Loosen the pressure switch (2) and remove it together with the O-ring (3) from the T-fitting (4).
(5) Discard the O-ring.
(6) Install the PLUG - BLANKING in the open ports.
Subtask 29-12-17-020-051-B ** ON A/C NOT FOR ALL (1) Disconnect the electrical connector (1).
(2) Put a CAP - BLANKING on the disconnected electrical connector.
(3) Cut and remove the lockwire.
(4) Loosen the pressure switch (2) and remove it together with the O-ring (3) from the T-fitting (4).
(5) Discard the O-ring.
(6) Install the PLUG - BLANKING in the open ports.
A. Removal of the Electric Pump Pressure-Switch
(2) Put a CAP - BLANKING on the disconnected electrical connector.
(3) Cut and remove the lockwire.
(4) Loosen the pressure switch (3) and remove it together with the O-ring (2) from the switch manifold (1).
(5) Discard the O-ring (2).
(6) Install the PLUG - BLANKING in the open ports.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(1) Disconnect the electrical connector (4). (2) Put a CAP - BLANKING on the disconnected electrical connector.
(3) Cut and remove the lockwire.
(4) Loosen the pressure switch (3) and remove it together with the O-ring (2) from the switch manifold (1).
(5) Discard the O-ring (2).
(6) Install the PLUG - BLANKING in the open ports.
Electric Pump Pressure-Switch