Removal of the Blue Electric-Pump Current Transformer
TASK 29-12-15-000-001-A
Removal of the Blue Electric-Pump Current Transformer
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 29-12-15-941-051-A
Subtask 29-12-15-020-051-A
[Rev.10 from 2021]
2026.04.01 00:18:53 UTC
Removal of the Blue Electric-Pump Current Transformer
WARNING:
ISOLATE ALL THE AIRCRAFT ELECTRICAL CIRCUITS.
CAUTION:
MAKE MATCH MARKS ON ALL THE ELECTRICAL WIRES BEFORE YOU DISCONNECT THEM. INCORRECT CONNECTION OF WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
FIN: 2706GJ
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121AL, 822 |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 29-12-15-941-051-A
A. Safety Precautions
(1) Make sure that the external power connector is not connected to the aircraft receptacle (20XG) (receptacle behind the access door 121AL).
(2) Put WARNING NOTICE(S) on the access door 121AL to tell persons not to connect the external power connector.
Subtask 29-12-15-860-050-A (1) Make sure that the external power connector is not connected to the aircraft receptacle (20XG) (receptacle behind the access door 121AL).
(2) Put WARNING NOTICE(S) on the access door 121AL to tell persons not to connect the external power connector.
B. Aircraft Maintenance Configuration
(1) In the cockpit, on the overhead panel 35VU, make sure that these pushbutton switches are released:
Subtask 29-12-15-010-050-A (1) In the cockpit, on the overhead panel 35VU, make sure that these pushbutton switches are released:
- APU GEN,
- 1 BAT 2,
- GEN 1, GEN 2,
- EXT PWR.
- 21VU (EMER ELEC PWR),
- 25VU (APU),
- 35VU (ELEC).
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position at the access door 822.
(2) Open the access door 822.
(3) Remove the access cover (1) from the panel 107VU.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) in position at the access door 822.
(2) Open the access door 822.
(3) Remove the access cover (1) from the panel 107VU.
Subtask 29-12-15-020-051-A
A. Removal of the Current Transformer
(1) Disconnect the electrical connector (9) from the transformer (8).
(2) Put CAP - BLANKING on the electrical connector (9) and on the electrical connector of the transformer (8).
(3) Identify the electrical wires (4).
(4) Remove the screw (7) and the washer (6).
(5) Remove the nuts (11), the washers (12) and disconnect the electrical wires (4) from the contactor (10).
(6) Remove the screws (2) and the washers (3).
(7) Pull and release the transformer (8) from the electrical wires (4) and remove it.
(1) Disconnect the electrical connector (9) from the transformer (8).
(2) Put CAP - BLANKING on the electrical connector (9) and on the electrical connector of the transformer (8).
(3) Identify the electrical wires (4).
(4) Remove the screw (7) and the washer (6).
(5) Remove the nuts (11), the washers (12) and disconnect the electrical wires (4) from the contactor (10).
(6) Remove the screws (2) and the washers (3).
(7) Pull and release the transformer (8) from the electrical wires (4) and remove it.
Blue Electric-Pump Current Transformer