Removal of the Actuator - Engine Pump Fire-Valve
TASK 29-11-52-000-002-A
Removal of the Actuator - Engine Pump Fire-Valve
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 29-11-52-941-057-A
Subtask 29-11-52-020-051-B
[Rev.10 from 2021]
2026.04.01 00:18:38 UTC
Removal of the Actuator - Engine Pump Fire-Valve
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
FIN: 1046GK
1. Reason for the JobSelf Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 574AB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 29-00-00-864-001-A | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
| TASK 29-00-00-910-002-A | Safety Procedures of the Hydraulic System |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
Subtask 29-11-52-941-057-A
A. Safety Precautions
(2) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the Green hydraulic system.
(3) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
Subtask 29-11-52-864-051-A WARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
(1) You must obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002) when you do work on the hydraulic system. (2) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the Green hydraulic system.
(3) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
B. Depressurize the Applicable Hydraulic Systems
(2) Depressurize the Green Hydraulic system reservoir (Ref. AMM TASK 29-14-00-614-001).
Subtask 29-11-52-865-055-A WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Depressurize the Green Hydraulic system (Ref. AMM TASK 29-00-00-864-001). (2) Depressurize the Green Hydraulic system reservoir (Ref. AMM TASK 29-14-00-614-001).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 29-11-52-010-053-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | HYD/FIRE VALVE/G/ENG1 | 1703GK | C13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/MONG | 1702GK | R34 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/MONG | 1702GK | R33 |
D. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT) in position, below zone 574.
(2) Open the access panel 574AB.
Subtask 29-11-52-010-053-B ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT) in position, below zone 574.
(2) Open the access panel 574AB.
D. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT) in position, below zone 574.
(2) Remove the access panel 574AB.
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT) in position, below zone 574.
(2) Remove the access panel 574AB.
Subtask 29-11-52-020-051-B
A. Removal of the Actuator from the Engine Pump Fire-Valve
(1) Disconnect the electrical connector (8).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the screw (10) and disconnect the bonding strap (9) from the actuator (1).
(4) Loosen the screws (4) sufficiently to remove the clamp halves (3) and (7) from the actuator (1). Remove and discard the O-rings (2).
(5) Remove the actuator (1), from the adaptor plate (5).
(6) Put blanking covers on the openings of the adaptor plate (5), and the actuator (1).
(1) Disconnect the electrical connector (8).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the screw (10) and disconnect the bonding strap (9) from the actuator (1).
(4) Loosen the screws (4) sufficiently to remove the clamp halves (3) and (7) from the actuator (1). Remove and discard the O-rings (2).
(5) Remove the actuator (1), from the adaptor plate (5).
(6) Put blanking covers on the openings of the adaptor plate (5), and the actuator (1).
Actuator - Engine Pump Fire-Valve (1046GK)