Installation of the Engine-Pump Case-Drain Filter
TASK 29-11-43-400-040-A
Installation of the Engine-Pump Case-Drain Filter
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 29-11-43-860-058-A ** ON A/C NOT FOR ALL
Subtask 29-11-43-420-057-A ** ON A/C NOT FOR ALL
Subtask 29-11-43-942-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:16:05 UTC
Installation of the Engine-Pump Case-Drain Filter
WARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
WARNING:
DO NOT TOUCH THE HYDRAULIC SYSTEM COMPONENTS FOR A SHORT TIME AFTER THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS STAY HOT FOR SOME TIME AND CAN CAUSE INJURY.
CAUTION:
DO NOT LET HYDRAULIC FLUID FALL ON THE ENGINE. UNWANTED HYDRAULIC FLUID MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH. THE FLUID CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
FIN: 1084GM ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.02ABA1) | Phosphate Ester Hydraulic Fluid-General Power - - |
| (Material No.14QFB1) | Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 437AL |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 25 | PACKING | AIPC 29-11-43-01-020 |
| 7 | PACKINGS | AIPC 29-11-43-01-020 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 29-10-00-864-001-A | Depressurize the Green Hydraulic System |
| TASK 29-11-00-710-001-A | Operational Test of the Green Hydraulic System |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
Subtask 29-11-43-860-058-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the Green hydraulic system is depressurized (Ref. AMM TASK 29-10-00-864-001).
(2) Make sure that the Green hydraulic reservoir is depressurized (Ref. AMM TASK 29-14-00-614-001).
(3) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the Green hydraulic system:
(5) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the engine
(6) Make sure that the fan-cowl door is open.
Subtask 29-11-43-941-061-A ** ON A/C NOT FOR ALL (1) Make sure that the Green hydraulic system is depressurized (Ref. AMM TASK 29-10-00-864-001).
(2) Make sure that the Green hydraulic reservoir is depressurized (Ref. AMM TASK 29-14-00-614-001).
(3) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the Green hydraulic system:
- on the ground service panel 197CB.
(5) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the engine
(6) Make sure that the fan-cowl door is open.
B. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(3) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the Green hydraulic system:
(6) Make sure that a CONTAINER 5 L (1.32 USGAL) is below the case drain filter.
4. Procedure(1) On the center pedestal, on the ENG panel 115VU:
- make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to start the engine.
(3) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the Green hydraulic system:
- in the cockpit, on the HYD section of the overhead panel 40VU.
- make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(6) Make sure that a CONTAINER 5 L (1.32 USGAL) is below the case drain filter.
Subtask 29-11-43-420-057-A ** ON A/C NOT FOR ALL
A. Installation of the Case-Drain Filter
BEFORE SB RA32029-5
(1) Remove the blanking covers from the ports of the hydraulic pump case drain filter module (5) and from the threads that attach the unions (10) to the filter module (5).
(2) Lubricate the AIPC 29-11-43-01-020 PACKINGS (7) with Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) and put on the unions (10). Install the unions (10) in the filter module ports.
(3) TORQUE the unions (10) to between 300 and 250 lbf.in (3.39 and 2.83 m.daN )
.
(4) Attach the filter module (5) to the filter support bracket with the four bolts (15) and the washers (20).
(5) TORQUE the bolts (15) to between 70 and 50 lbf.in (0.79 and 0.57 m.daN )
.
(6) Safety the two left filter-module mount bolts (15) with14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(7) Safety the filter element case with lockwire to the two right filter module mount bolts (15).
(8) Remove the blanking covers from the case drain upper and lower hose couplings and the filter module unions (10).
(9) Connect the hoses to the filter module unions (10).
(10) TORQUE the coupling nuts to between 245 and 215 lbf.in (2.77 and 2.43 m.daN )
.
Subtask 29-11-43-420-053-A ** ON A/C NOT FOR ALL BEFORE SB RA32029-5
(1) Remove the blanking covers from the ports of the hydraulic pump case drain filter module (5) and from the threads that attach the unions (10) to the filter module (5).
(2) Lubricate the AIPC 29-11-43-01-020 PACKINGS (7) with Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) and put on the unions (10). Install the unions (10) in the filter module ports.
(3) TORQUE the unions (10) to between 300 and 250 lbf.in (3.39 and 2.83 m.daN )
. (4) Attach the filter module (5) to the filter support bracket with the four bolts (15) and the washers (20).
(5) TORQUE the bolts (15) to between 70 and 50 lbf.in (0.79 and 0.57 m.daN )
. (6) Safety the two left filter-module mount bolts (15) with
(7) Safety the filter element case with lockwire to the two right filter module mount bolts (15).
(8) Remove the blanking covers from the case drain upper and lower hose couplings and the filter module unions (10).
(9) Connect the hoses to the filter module unions (10).
(10) TORQUE the coupling nuts to between 245 and 215 lbf.in (2.77 and 2.43 m.daN )
. B. Removal of the Case-Drain Filter
AFTER SB RA32029-5
(1) Remove the blanking covers from the ports of the filter module (5), the union (10) and the elbow (35).
(2) Lubricate the packings (7) with Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) and put on the union (10). Install the union (10) in the port at the top of the filter module.
(3) TORQUE the union (10) to between 300 and 250 lbf.in (3.39 and 2.83 m.daN )
.
(4) Lubricate the packings AIPC 29-11-43-01-020 PACKING (25) with Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) . Install the packing (25), the nut (30) and the elbow (35) into the port of the filter module.
(5) TORQUE the nut (30) and elbow (35) on the filter module to between 200 and 180 lbf.in (2.26 and 2.03 m.daN )
.
(6) Attach the filter module (5) to the filter support bracket with the four bolts (15) and the washers (20).
(7) TORQUE the bolts (15) to between 70 and 50 lbf.in (0.79 and 0.57 m.daN )
.
(8) Safety the two left filter-module mount bolts (15) with14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(9) Safety the filter element case with lockwire to the two right filter module mount bolts (15).
(10) Remove the blanking covers from the case drain upper and lower hose couplings
(11) Connect the case drain upper hose to the union (10) on the filter module.
(12) TORQUE the upper hose coupling nuts to between 245 and 215 lbf.in (2.77 and 2.43 m.daN )
.
(13) Connect the case drain lower hose to the elbow (35) on the filter module.
(14) TORQUE the lower hose coupling nuts to between 245 and 215 lbf.in (2.77 and 2.43 m.daN )
.
Subtask 29-11-43-710-053-A ** ON A/C NOT FOR ALL AFTER SB RA32029-5
(1) Remove the blanking covers from the ports of the filter module (5), the union (10) and the elbow (35).
(2) Lubricate the packings (7) with Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) and put on the union (10). Install the union (10) in the port at the top of the filter module.
(3) TORQUE the union (10) to between 300 and 250 lbf.in (3.39 and 2.83 m.daN )
. (4) Lubricate the packings AIPC 29-11-43-01-020 PACKING (25) with Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) . Install the packing (25), the nut (30) and the elbow (35) into the port of the filter module.
(5) TORQUE the nut (30) and elbow (35) on the filter module to between 200 and 180 lbf.in (2.26 and 2.03 m.daN )
. (6) Attach the filter module (5) to the filter support bracket with the four bolts (15) and the washers (20).
(7) TORQUE the bolts (15) to between 70 and 50 lbf.in (0.79 and 0.57 m.daN )
. (8) Safety the two left filter-module mount bolts (15) with
(9) Safety the filter element case with lockwire to the two right filter module mount bolts (15).
(10) Remove the blanking covers from the case drain upper and lower hose couplings
(11) Connect the case drain upper hose to the union (10) on the filter module.
(12) TORQUE the upper hose coupling nuts to between 245 and 215 lbf.in (2.77 and 2.43 m.daN )
. (13) Connect the case drain lower hose to the elbow (35) on the filter module.
(14) TORQUE the lower hose coupling nuts to between 245 and 215 lbf.in (2.77 and 2.43 m.daN )
. NOTE: Use a second WRENCH - TORQUE to hold the fittings when you torque the coupling nuts. This prevents damage to the hose.
C. Operational Test
(1) Do an operational test of the Green hydraulic system (Ref. AMM TASK 29-11-00-710-001).
(2) During the dry motoring of the Engine 1, make sure that:
5. Close-up(1) Do an operational test of the Green hydraulic system (Ref. AMM TASK 29-11-00-710-001).
(2) During the dry motoring of the Engine 1, make sure that:
- there are no leaks from the case drain filter,
- the clogging indicator of the filter is not extended.
Subtask 29-11-43-942-051-A ** ON A/C NOT FOR ALL
A. Remove the safety precautions
(1) Remove the WARNING NOTICE(S).
(2) Remove the container.
(3) Make sure that the work area is clean and clear of tools and other items.
Subtask 29-11-43-410-052-A ** ON A/C NOT FOR ALL (1) Remove the WARNING NOTICE(S).
(2) Remove the container.
(3) Make sure that the work area is clean and clear of tools and other items.
B. Close Access
(1) Close the left fan-cowl door 437AL (Ref. AMM TASK 71-13-00-410-040).
(2) Remove the access platform(s).
(1) Close the left fan-cowl door 437AL (Ref. AMM TASK 71-13-00-410-040).
(2) Remove the access platform(s).
Engine-Pump Case-Drain Filter