W DOC AIRBUS | AMM A320F

Removal of the Engine-Pump Case-Drain Filter


TASK 29-11-43-000-010-A
Removal of the Engine-Pump Case-Drain Filter


WARNING: DO NOT TOUCH THE HYDRAULIC SYSTEM COMPONENTS FOR A SHORT TIME AFTER THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS STAY HOT FOR SOME TIME AND CAN CAUSE INJURY.
WARNING: DO NOT GET HYDRAULIC FLUID ON YOUR SKIN, IN YOUR EYES OR IN YOUR MOUTH. HYDRAULIC FLUID IS POISONOUS AND CAN GO THROUGH YOUR SKIN AND INTO YOUR BODY. FLUSH HYDRAULIC FLUID FROM YOUR EYES, MOUTH OR SKIN WITH WATER. GET MEDICAL AID IF YOU GET HYDRAULIC FLUID IN YOUR EYES OR MOUTH.
CAUTION: DO NOT LET HYDRAULIC FLUID FALL ON THE ENGINE. UNWANTED HYDRAULIC FLUID MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH. THE FLUID CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
FIN: 1084GM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
2
CONTAINER 5 L (1.32 USGAL)
No specific
AR
COVER - BLANKING
No specific
2
WARNING NOTICE(S)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 29-10-00-864-001-A
Depressurize the Green Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
3. Job Set-up
Subtask 29-11-43-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Depressurize the Green hydraulic system (Ref. AMM TASK 29-10-00-864-001).
   (2) Depressurize the Green hydraulic reservoir (Ref. AMM TASK 29-14-00-614-001).
   (3) Put WARNING NOTICE(S) in position to tell persons not to pressurize the Green hydraulic system:
  • on the ground service panel 197CB.
   (4) Put WARNING NOTICE(S) on the access door 195BB to tell persons not to pressurize the Green hydraulic reservoir.
Subtask 29-11-43-941-050-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
  • put WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) Put WARNING NOTICE(S) in position to tell persons not to pressurize the Green hydraulic system:
  • in the cockpit, on the HYD section of the overhead panel 40VU.
   (4) On the overhead maintenance panel 50VU:
  • make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
   (5) Put WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
   (6) Put a CONTAINER 5 L (1.32 USGAL) under the case drain filter.
Subtask 29-11-43-010-050-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the fan-cowl doors 437AL/438AR (Ref. AMM TASK 71-13-00-010-010).
   (2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the engine.
4. Procedure
Subtask 29-11-43-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Case-Drain Filter Assembly
   (1) Remove the bolt (12) from the bracket (11) and the clip (13).
   (2) Put a clean CONTAINER 5 L (1.32 USGAL) in position to catch the drained hydraulic fluid.
   (3) Make a note of the position of these parts, they must be put in the same position during installation:
     (a) The case drain filter (10).
     (b) The seals (1) and (4).
     (c) The unions (2) and (5).
     (d) The bolts (7) and (9).
     (e) The bracket (8).
   (4) Hold the union (5) with an applicable wrench and disconnect the connector nut (6).
   (5) Let the hydraulic fluid drain into the container.
   (6) Hold the union (2) with an applicable wrench and disconnect the connector nut (3).
   (7) Remove the two bolts (7) which attach the bracket (8) and the case drain filter (10) to the bracket (11).
   (8) Hold the case drain filter (10) and remove the two bolts (9) which attach the case drain filter (10) to the bracket (11).
   (9) Remove the case drain filter (10) from the engine.
   (10) Remove the container and discard the drained hydraulic fluid.
Subtask 29-11-43-020-052-A ** ON A/C NOT FOR ALL
B. Removal of the Unions
   (1) Remove the unions (2) and (5) from the case drain filter (10).
   (2) Remove and discard the seals (1) and (4).
   (3) Install the applicable COVER - BLANKING to all the openings.
Subtask 29-11-43-620-050-A ** ON A/C NOT FOR ALL
C. Install the applicable covers/caps/plugs to all the openings.
[Rev.10 from 2021] 2026.04.01 00:16:12 UTC