W DOC AIRBUS | AMM A320F

Installation of the Engine 1 Green Hydraulic Pump Delivery Check Valve


TASK 29-11-36-400-001-A
Installation of the Engine 1 Green Hydraulic Pump Delivery Check Valve


WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES.
WARNING: DO NOT TOUCH THE HYDRAULIC SYSTEM COMPONENTS FOR A SHORT TIME AFTER THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS STAY HOT FOR SOME TIME AND CAN CAUSE INJURY.
CAUTION: DO NOT LET HYDRAULIC FLUID FALL ON THE ENGINE. UNWANTED HYDRAULIC FLUID MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH. THE FLUID CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
ZONE: 410
FIN: 1050GM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CONTAINER 5 L (1.32 USGAL)
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 10.7 and 9.7 m.daN (78.91 and 71.53 lbf.ft ) T
No specific
Torque wrench: range to between 13 and 12 m.daN (95.87 and 88.50 lbf.ft ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.02ABA1)
Phosphate Ester Hydraulic Fluid-General Power - -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
410
ENG 1 PYLON BOX AND FORWARD FAIRING
437AL
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
3
O-RING
AIPC 29-11-06-01-060
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 12-12-29-611-001-A
Fill the Hydraulic Fluid Reservoir with a Hand Pump
TASK 20-29-00-911-002-A
Removal/Installation of an O-ring (Hydraulic Systems)
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 29-10-00-864-001-A
Depressurize the Green Hydraulic System
TASK 29-11-00-710-001-A
Operational Test of the Green Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
TASK 31-60-00-860-002-A
EIS Stop Procedure
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
3. Job Set-up
Subtask 29-11-36-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002)
   (2) Make sure that the Green hydraulic system is depressurized (Ref. AMM TASK 29-10-00-864-001).
   (3) Make sure that the Green hydraulic reservoir is depressurized (Ref. AMM TASK 29-14-00-614-001).
   (4) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the Green hydraulic system:
  • on the ground service panel 197CB.
   (5) Make sure that the WARNING NOTICE(S) is (are) in position on the access door 195BB to tell persons not to pressurize the Green hydraulic reservoir.
   (6) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at engine.
   (7) Make sure that the left fan-cowl door 437AL is open.
Subtask 29-11-36-941-051-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
  • make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the Green hydraulic system:
  • in the cockpit, on the HYD section of the overhead panel 40VU.
   (4) On the overhead maintenance panel 50VU:
  • make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
   (5) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to energize the FADEC 1(2).
   (6) Make sure that a CONTAINER 5 L (1.32 USGAL) is below the hydraulic tube connection to the switch (25) to collect the remaining fluid.
4. Procedure
Subtask 29-11-36-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Green Engine 1 Pump Delivery Check Valve (1050GM)
   (1) Apply Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) to the new O-ring (3).
   (2) Install the AIPC 29-11-06-01-060 O-RING (3) on the check valve (1). (Ref. AMM TASK 20-29-00-911-002)
   (3) Remove the blanking plug from the panel (4).
   (4) Install the check valve (1) on the panel (4).
   (5) TORQUE the check valve (1) to between 13 and 12 m.daN (95.87 and 88.50 lbf.ft ) T.
   (6) Remove the blanking plug from the disconnected hose (2).
   (7) Apply Phosphate Ester Hydraulic Fluid-General Power - - (Material No.
02ABA1) to the threads of the coupling nut of the hose (2).
   (8) Connect the hose (2) to the check valve (1).
   (9) TORQUE the coupling nut of the hose (2) to between 10.7 and 9.7 m.daN (78.91 and 71.53 lbf.ft ) T.
Subtask 29-11-36-710-050-A ** ON A/C NOT FOR ALL
B. Test
   (1) Do the operational test of the Green hydraulic system (
Ref. AMM TASK 29-11-00-710-001).
   (2) After the dry-motoring, make sure that there were no leaks from the check valve (1).
   (3) Make sure that the level of the hydraulic fluid in the Green reservoir is correct. If necessary, fill the reservoir (Ref. AMM TASK 12-12-29-611-001).
5. Close-up
Subtask 29-11-36-942-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Remove the WARNING NOTICE(S).
   (2) Remove the container.
   (3) Make sure that the work area is clean and clear of tools and other items.
   (4) Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).
   (5) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
Subtask 29-11-36-410-050-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Remove the access platform(s).
   (2) Close the left fan-cowl door 437AL (Ref. AMM TASK 71-13-00-410-040).
Subtask 29-11-36-410-050-B ** ON A/C NOT FOR ALL
B. Close Access
   (1) Remove the access platform(s).
   (2) Close the left fan-cowl door 437AL (Ref. AMM TASK 71-13-00-410-010).