W DOC AIRBUS | AMM A320F

Check Clogging Indicator on Engine Driven Pump (EDP) Case Drain Filter (Pop Out not Protruding)


TASK 29-10-00-200-007-A
Check Clogging Indicator on Engine Driven Pump (EDP) Case Drain Filter (Pop Out not Protruding)


ZONE: 435
ZONE: 437
ZONE: 445
ZONE: 447
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
435
FAN AND ACCESSORY GEARBOX
437
FAN COWL
445
FAN AND ACCESSORY GEARBOX
447
FAN COWL
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 29-11-43-610-040-A
Servicing of the Engine-Pump Case-Drain Filter
TASK 29-11-43-610-041-A
Servicing the Engine-Pump Case-Drain Filter
TASK 29-13-43-610-040-A
Servicing of the Engine Pump Case-Drain Filter
TASK 29-13-43-610-041-A
Servicing of the Engine Pump Case-Drain Filter
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
3. Job Set-up
Subtask 29-10-00-010-067-A ** ON A/C NOT FOR ALL
A. Open the left fan cowl of the left and right engines (Ref. AMM TASK 71-13-00-010-040).
4. Procedure
Subtask 29-10-00-210-056-A ** ON A/C NOT FOR ALL
A. Check of the Clogging Indicator of the Case Drain Filters of the Engine-Driven Pumps
   (1) Look at the clogging indicator on the case drain filter(s). Make sure that it does not show that the case drain filter(s) is (are) too dirty (the red indicator button is not out).
   (2) If an indicator shows that the case drain filter(s) is (are) too dirty:
     (a) Do the servicing of the engine-pump case-drain filter(s) (Ref. AMM TASK 29-11-43-610-040) and/or (Ref. AMM TASK 29-13-43-610-040).
Subtask 29-10-00-210-056-B ** ON A/C NOT FOR ALL
A. Check of the Clogging Indicator of the Case Drain Filters of the Engine-Driven Pumps
   (1) Look at the clogging indicator on the case drain filter(s). Make sure that it does not show that the case drain filter(s) is (are) too dirty (the red indicator button is not out).
   (2) If an indicator shows that the case drain filter(s) is (are) too dirty:
     (a) Do the servicing of the engine-pump case-drain filter(s) (Ref. AMM TASK 29-11-43-610-041) and/or (Ref. AMM TASK 29-13-43-610-041).
5. Close-up
Subtask 29-10-00-410-067-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the left fan cowls of the left and right engines (Ref. AMM TASK 71-13-00-410-040).