Removal of the Auxiliary Fuel Management Computer (AFMC)


TASK 28-51-35-000-001-A
Removal of the Auxiliary Fuel Management Computer (AFMC)


WARNING: OBEY THE FUEL SAFETY PROCEDURES.
ZONE: 120
FIN: 2QN ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
120
AVIONICS COMPARTMENT
811
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 28-00-00-910-001-A
Fuel Safety Procedures
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
3. Job Set-up
Subtask 28-51-35-861-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
   (2) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (3) Put the WARNING NOTICE(S) on the panels that follow, to tell persons not to operate the fuel system:
  • Refuel/Defuel panels 800VU and 801VU
  • Fuel control panel 40VU
  • Additional Center Tank (ACT) control panel 28VU.
Subtask 28-51-35-865-053-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAFMC SPLY3QNB08
121VUFUEL/AFMC/SPLY4QNK19
121VUFUEL/RFL/ON BAT5QNR30
Subtask 28-51-35-010-050-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below access door 811.
   (2) Open access door 811 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure
Subtask 28-51-35-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the AFMC
   (1) Loosen and lower the knurled nuts (4).
CAUTION: DO NOT TOUCH THE CONNECTOR PINS OR OTHER CONDUCTORS ON THE COMPONENT DURING THE PROCEDURE. IF YOU TOUCH THESE CONDUCTORS, ELECTROSTATIC DISCHARGE CAN CAUSE DAMAGE TO COMPONENT.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
   (2) Carefully pull the AFMC (1) from its rack (2) to disconnect electrical connectors (3).
   (3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.