Installation of the Relay
TASK 28-46-45-400-001-A
Installation of the Relay
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-46-45-010-051-A ** ON A/C NOT FOR ALL
Subtask 28-46-45-420-050-A ** ON A/C NOT FOR ALL
Subtask 28-46-45-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:18:18 UTC
Installation of the Relay
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 822 |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 28-46-45-010-051-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 822 of the electronics compartment.
(2) Make sure that the access door 822 is open.
(3) Make sure that the access door 103VU (5) is open.
Subtask 28-46-45-865-051-A ** ON A/C NOT FOR ALL (1) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 822 of the electronics compartment.
(2) Make sure that the access door 822 is open.
(3) Make sure that the access door 103VU (5) is open.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 56QJ (RELAYHI LVL IND, ACT 1) | |||
| 121VU | ACT1/REFUEL & SPLY | 33QU | L29 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 57QJ (RELAYCTL HI LVL, IND ACT 2) | |||
| 121VU | ACT2/REFUEL & SPLY | 34QU | L28 |
Subtask 28-46-45-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Relay
(1) Put the relay (3) in position on the barrels (2) of the base (1).
(2) Tighten the screws (4).
Subtask 28-46-45-865-052-A ** ON A/C NOT FOR ALL (1) Put the relay (3) in position on the barrels (2) of the base (1).
(2) Tighten the screws (4).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 56QJ (RELAYHI LVL IND, ACT 1) | |||
| 121VU | ACT1/REFUEL & SPLY | 33QU | L29 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 57QJ (RELAYCTL HI LVL, IND ACT 2) | |||
| 121VU | ACT2/REFUEL & SPLY | 34QU | L28 |
Subtask 28-46-45-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 103VU (5).
(3) Close the access door 822.
(4) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 103VU (5).
(3) Close the access door 822.
(4) Remove the access platform(s).
Relay (56QJ and 57QJ) - Location and Detail