Removal of the Relay
TASK 28-46-45-000-001-A
Removal of the Relay
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-46-45-865-050-A ** ON A/C NOT FOR ALL
Subtask 28-46-45-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:18:18 UTC
Removal of the Relay
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 822 |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 28-46-45-865-050-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 28-46-45-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 56QJ (RELAYHI LVL IND, ACT 1) | |||
| 121VU | ACT1/REFUEL & SPLY | 33QU | L29 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 57QJ (RELAYCTL HI LVL, IND ACT 2) | |||
| 121VU | ACT2/REFUEL & SPLY | 34QU | L28 |
B. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 822 of the electronics compartment.
(2) Open the access door 822.
(3) Open the access door of the relay box 103VU (5).
4. Procedure(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 822 of the electronics compartment.
(2) Open the access door 822.
(3) Open the access door of the relay box 103VU (5).
Subtask 28-46-45-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Relay
(1) Hold the relay (3).
(2) Loosen the screws (4).
(3) Remove the relay (3).
(1) Hold the relay (3).
(2) Loosen the screws (4).
(3) Remove the relay (3).
Relay (56QJ and 57QJ) - Location and Detail