Removal of the Vent Surge Tank-Harness
TASK 28-46-43-000-001-A
Removal of the Vent Surge Tank-Harness
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-46-43-941-052-A
Subtask 28-46-43-020-052-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:18:17 UTC
Removal of the Vent Surge Tank-Harness
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Reason for the JobSelf Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | CORD - PATCH |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [34QJ1] (HARNESS-L VENT SURGE TK) | |
| 550CB | |
| 550DB | |
| 575LB | |
| 560AB | |
| 540QB, 550AB, 550BB | |
| FOR [34QJ2] (HARNESS-R VENT SURGE TK) | |
| 650CB | |
| 660AB | |
| 640QB, 650AB, 650BB | |
| 650DB | |
| 675LB | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-10-00-910-001-A | Safety Procedures When You Do Work in a Fuel Tank |
| TASK 28-10-00-910-002-A | Access to the Fuel Tanks and the Work Areas |
| TASK 28-12-45-000-001-A | Removal of the Panel Assembly |
| TASK 28-25-00-650-003-A | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 28-25-00-650-003-A-01 | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 57-27-11-000-002-A | Removal of the Access Panel |
| TASK 57-51-37-000-005-A | Removal of the Access Panels 575KB(675KB), 575LB(675LB), 575MB(675MB) |
Subtask 28-46-43-941-052-A
A. Safety Precautions
(2) Put the SAFETY BARRIER(S) in position.
Subtask 28-46-43-650-054-A WARNING:
BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
(1) You must obey the fuel safety procedures (Ref. AMM TASK 28-10-00-910-001) when you do work in a fuel tank. (2) Put the SAFETY BARRIER(S) in position.
B. Fuel Configuration
(1) Drain the remaining fuel from the applicable vent surge tank (Ref. AMM TASK 28-25-00-650-003).
Subtask 28-46-43-865-050-A (1) Drain the remaining fuel from the applicable vent surge tank (Ref. AMM TASK 28-25-00-650-003).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 28-46-43-010-053-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FUEL/XFR VALVE1/WING/R | 2QP | A11 |
| 49VU | FUEL/XFR VALVE1/WING/L | 1QP | A10 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FUEL/AFT LOW LVL/& OVFL/WING R | 44QJ | A11 |
| 49VU | FUEL/AFT LOW LVL/& OVFL/WING L | 43QJ | A10 |
D. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT) in position below the applicable access panels 550DB, 560AB and 550CB (650DB, 660AB and 650CB).
(2) Remove the applicable access panels 550CB (650CB), 550DB (650DB) and 560AB (660AB) (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-27-11-000-002), (Ref. AMM TASK 28-12-45-000-001):
(a) FOR [34QJ1] (HARNESS-L VENT SURGE TK)
(b) FOR [34QJ2] (HARNESS-R VENT SURGE TK)
Subtask 28-46-43-010-053-B ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 4M (13 FT) in position below the applicable access panels 550DB, 560AB and 550CB (650DB, 660AB and 650CB).
(2) Remove the applicable access panels 550CB (650CB), 550DB (650DB) and 560AB (660AB) (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-27-11-000-002), (Ref. AMM TASK 28-12-45-000-001):
(a) FOR [34QJ1] (HARNESS-L VENT SURGE TK)
(b) FOR [34QJ2] (HARNESS-R VENT SURGE TK)
D. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT) in position below the applicable access panels 550CB, 550DB and 575LB (650CB, 650DB and 675LB).
(2) Remove the applicable access panels 550CB (650CB), 550DB (650DB) and 575LB (675LB) (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-27-11-000-002), (Ref. AMM TASK 57-51-37-000-005), (Ref. AMM TASK 28-12-45-000-001):
(a) FOR [34QJ1] (HARNESS-L VENT SURGE TK)
(b) FOR [34QJ2] (HARNESS-R VENT SURGE TK)
Subtask 28-46-43-010-053-C ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 4M (13 FT) in position below the applicable access panels 550CB, 550DB and 575LB (650CB, 650DB and 675LB).
(2) Remove the applicable access panels 550CB (650CB), 550DB (650DB) and 575LB (675LB) (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-27-11-000-002), (Ref. AMM TASK 57-51-37-000-005), (Ref. AMM TASK 28-12-45-000-001):
(a) FOR [34QJ1] (HARNESS-L VENT SURGE TK)
(b) FOR [34QJ2] (HARNESS-R VENT SURGE TK)
D. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT) in position below the applicable access panels 540QB, 550AB, 550BB and 550CB (640QB, 650AB, 650BB and 650CB).
(2) Remove the applicable access panels 540QB (640QB), 550AB (650AB), 550BB (650BB) and 550CB (650CB) (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-27-11-000-002), (Ref. AMM TASK 28-12-45-000-001):
(a) FOR [34QJ1] (HARNESS-L VENT SURGE TK)
(b) FOR [34QJ2] (HARNESS-R VENT SURGE TK)
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT) in position below the applicable access panels 540QB, 550AB, 550BB and 550CB (640QB, 650AB, 650BB and 650CB).
(2) Remove the applicable access panels 540QB (640QB), 550AB (650AB), 550BB (650BB) and 550CB (650CB) (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-27-11-000-002), (Ref. AMM TASK 28-12-45-000-001):
(a) FOR [34QJ1] (HARNESS-L VENT SURGE TK)
(b) FOR [34QJ2] (HARNESS-R VENT SURGE TK)
Subtask 28-46-43-020-052-A ** ON A/C NOT FOR ALL
A. Removal of the Vent Surge Tank-Harness
(1) Get access through the opening 550CB(650CB) and loosen :
(3) Disconnect the end of the harness (5) from the sensor 28QJ1 (28QJ2).
(4) Attach a length of CORD - PATCH to the inboard end of the harness (5). This will help to install a new harness.
(5) Get access through the opening 560AB(660AB) and disconnect the bayonet electrical connector (12) from the connector (8).
(6) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(7) Remove the nut (11) and the washer (10).
(8) Get access through the opening 550DB(650DB) and cut and discard the cable tie (7).
(9) Remove the connector (8) from the hole in RIB26.
(10) Remove and discard the O-ring (9).
(11) Carefully pull the harness (5) and the attached end of the CORD - PATCH, outboard from the conduit (3).
(12) When the CORD - PATCH hangs from the outboard end of the conduit (3), release it from the harness (5).
Subtask 28-46-43-020-052-B ** ON A/C NOT FOR ALL (1) Get access through the opening 550CB(650CB) and loosen :
- the clamp screw (6)
- the electrical connector screws (1) and (2).
(3) Disconnect the end of the harness (5) from the sensor 28QJ1 (28QJ2).
(4) Attach a length of CORD - PATCH to the inboard end of the harness (5). This will help to install a new harness.
(5) Get access through the opening 560AB(660AB) and disconnect the bayonet electrical connector (12) from the connector (8).
(6) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(7) Remove the nut (11) and the washer (10).
(8) Get access through the opening 550DB(650DB) and cut and discard the cable tie (7).
(9) Remove the connector (8) from the hole in RIB26.
(10) Remove and discard the O-ring (9).
(11) Carefully pull the harness (5) and the attached end of the CORD - PATCH, outboard from the conduit (3).
(12) When the CORD - PATCH hangs from the outboard end of the conduit (3), release it from the harness (5).
A. Removal of the Vent Surge Tank-Harness
(1) Loosen the clamp screw (6) and the electrical connector screws (1) and (2).
(2) Cut and discard the cable ties (4).
(3) Disconnect the end of the harness (5) from the sensor 28QJ1 (28QJ2).
(4) Attach a length of CORD - PATCH to the inboard end of the harness (5). This will help to install a new harness.
(5) Disconnect the bayonet electrical connector (12) from the connector (8).
(6) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(7) Remove the nut (11) and the washer (10).
(8) Cut and discard the cable tie (7).
(9) Remove the connector (8) from the hole in the rear spar.
(10) Remove and discard the O-ring (9).
(11) Carefully pull the harness (5) and the attached end of the CORD - PATCH, outboard from the conduit (3).
(12) When the CORD - PATCH hangs from the outboard end of the conduit (3), release it from the harness (5).
Subtask 28-46-43-020-052-C ** ON A/C NOT FOR ALL (1) Loosen the clamp screw (6) and the electrical connector screws (1) and (2).
(2) Cut and discard the cable ties (4).
(3) Disconnect the end of the harness (5) from the sensor 28QJ1 (28QJ2).
(4) Attach a length of CORD - PATCH to the inboard end of the harness (5). This will help to install a new harness.
(5) Disconnect the bayonet electrical connector (12) from the connector (8).
(6) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(7) Remove the nut (11) and the washer (10).
(8) Cut and discard the cable tie (7).
(9) Remove the connector (8) from the hole in the rear spar.
(10) Remove and discard the O-ring (9).
(11) Carefully pull the harness (5) and the attached end of the CORD - PATCH, outboard from the conduit (3).
(12) When the CORD - PATCH hangs from the outboard end of the conduit (3), release it from the harness (5).
A. Removal of the Vent Surge Tank-Harness
(1) Loosen the clamp screw (9) and the electrical connector screws (10) and (6).
(2) Cut and discard the cable ties (7).
(3) Disconnect the end of the harness (8) from the sensor 28QJ1 (28QJ2).
(4) Attach a length of CORD - PATCH to the outboard end of the harness (8). This will help to install a new harness.
(5) Disconnect the connector (1) from the bayonet electrical connector (2).
(6) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(7) Remove the nuts (3), bolts (5) and the anti-rotation plate (4) from RIB22.
(8) Remove the bayonet electrical connector (2) from the hole in RIB22.
(9) Carefully pull the harness (8) and the attached end of the CORD - PATCH, inboard from the conduit.
(10) When the CORD - PATCH hangs from the inboard end of the conduit, release it from the harness (8).
(1) Loosen the clamp screw (9) and the electrical connector screws (10) and (6).
(2) Cut and discard the cable ties (7).
(3) Disconnect the end of the harness (8) from the sensor 28QJ1 (28QJ2).
(4) Attach a length of CORD - PATCH to the outboard end of the harness (8). This will help to install a new harness.
(5) Disconnect the connector (1) from the bayonet electrical connector (2).
(6) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(7) Remove the nuts (3), bolts (5) and the anti-rotation plate (4) from RIB22.
(8) Remove the bayonet electrical connector (2) from the hole in RIB22.
(9) Carefully pull the harness (8) and the attached end of the CORD - PATCH, inboard from the conduit.
(10) When the CORD - PATCH hangs from the inboard end of the conduit, release it from the harness (8).
Vent Surge Tank-Harness 34QJ1(34QJ2)