W DOC AIRBUS | AMM A320F

Installation of the Fuel-Level Sensing Control-Unit (FLSCU)


TASK 28-46-34-400-001-A
Installation of the Fuel-Level Sensing Control-Unit (FLSCU)


ZONE: 121
ZONE: 122
FIN: 7QJ ** ON A/C NOT FOR ALL
FIN: 9QJ ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
121
AVIONICS COMPARTMENT
122
AVIONICS COMPARTMENT
811
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 28-46-00-740-001-A
Functional (BITE) Test
3. Job Set-up
Subtask 28-46-34-010-051-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position.
   (2) Make sure that access door 811 is open.
   (3) On FUEL overhead panel 40VU:
  • Make sure that all the pushbutton switches are released (the OFF legends come on).
  • Make sure that the WARNING NOTICE(S) is in position to tell persons not to operate the fuel system.
   (4) On refuel/defuel control panel 800VU, make that the WARNING NOTICE(S) is in position to tell persons not to refuel/defuel the fuel tanks.
Subtask 28-46-34-865-051-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 7QJ (FLSCU1)
49VUFUEL/XFR VALVE1/WING/L1QPA10
** ON A/C NOT FOR ALL
49VUFUEL/AFT LOW LVL/& OVFL/WING L43QJA10
** ON A/C NOT FOR ALL
121VUFUEL/CTR TK/AUTO/CTL47QAR27
121VUFUEL/CTR TK/PUMPS1 AND 2/CTL AND IND31QAR25
** ON A/C NOT FOR ALL
121VUFUEL/XFR VALVE2/WING/R4QPM23
** ON A/C NOT FOR ALL
121VUFUEL/HI/LVL/SPLY1QJL25
** ON A/C NOT FOR ALL
121VUFUEL/CTR TK/AUTO/CTL3QLR27
121VUFUEL/CTR TK/L&R XFR/CTL & IND1QLR25
** ON A/C NOT FOR ALL
121VUFUEL/HI/LVL/SPLY1QJL24
** ON A/C NOT FOR ALL
121VUFUEL/FWD LOW LVL/WING/R45QJM23
** ON A/C NOT FOR ALL
FOR FIN: 9QJ (FLSCU2)
49VUFUEL/XFR VALVE1/WING/R2QPA11
** ON A/C NOT FOR ALL
49VUFUEL/AFT LOW LVL/& OVFL/WING R44QJA11
** ON A/C NOT FOR ALL
121VUFUEL/CTR TK/AUTO/CTL47QAR27
121VUFUEL/CTR TK/PUMPS1 AND 2/CTL AND IND32QAR26
** ON A/C NOT FOR ALL
121VUFUEL/XFR VALVE2/WING/L3QPM22
** ON A/C NOT FOR ALL
121VUFUEL/HI/LVL/SPLY1QJL25
** ON A/C NOT FOR ALL
121VUFUEL/CTR TK/AUTO/CTL3QLR27
121VUFUEL/CTR TK/L&R XFR/CTL & IND2QLR26
** ON A/C NOT FOR ALL
121VUFUEL/HI/LVL/SPLY1QJL24
** ON A/C NOT FOR ALL
121VUFUEL/FWD LOW LVL/WING/L46QJM22
4. Procedure
Subtask 28-46-34-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the FLSCU
   (1) Remove the blanking caps from the electrical connectors (3) and (5).
   (2) Install the FLSCU (1) on its rack (2).
   (3) Connect the FLSCU (1) to the electrical connector (3).
   (4) Attach the FLSCU (1) to its rack (2) with the knurled nut (4).
Subtask 28-46-34-865-052-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 7QJ (FLSCU1)
49VUFUEL/XFR VALVE1/WING/L1QPA10
** ON A/C NOT FOR ALL
49VUFUEL/AFT LOW LVL/& OVFL/WING L43QJA10
** ON A/C NOT FOR ALL
121VUFUEL/CTR TK/AUTO/CTL47QAR27
121VUFUEL/CTR TK/PUMPS1 AND 2/CTL AND IND31QAR25
** ON A/C NOT FOR ALL
121VUFUEL/XFR VALVE2/WING/R4QPM23
** ON A/C NOT FOR ALL
121VUFUEL/HI/LVL/SPLY1QJL25
** ON A/C NOT FOR ALL
121VUFUEL/CTR TK/AUTO/CTL3QLR27
121VUFUEL/CTR TK/L&R XFR/CTL & IND1QLR25
** ON A/C NOT FOR ALL
121VUFUEL/HI/LVL/SPLY1QJL24
** ON A/C NOT FOR ALL
121VUFUEL/FWD LOW LVL/WING/R45QJM23
** ON A/C NOT FOR ALL
FOR FIN: 9QJ (FLSCU2)
49VUFUEL/XFR VALVE1/WING/R2QPA11
** ON A/C NOT FOR ALL
49VUFUEL/AFT LOW LVL/& OVFL/WING R44QJA11
** ON A/C NOT FOR ALL
121VUFUEL/CTR TK/AUTO/CTL47QAR27
121VUFUEL/CTR TK/PUMPS1 AND 2/CTL AND IND32QAR26
** ON A/C NOT FOR ALL
121VUFUEL/XFR VALVE2/WING/L3QPM22
** ON A/C NOT FOR ALL
121VUFUEL/HI/LVL/SPLY1QJL25
** ON A/C NOT FOR ALL
121VUFUEL/CTR TK/AUTO/CTL3QLR27
121VUFUEL/CTR TK/L&R XFR/CTL & IND2QLR26
** ON A/C NOT FOR ALL
121VUFUEL/HI/LVL/SPLY1QJL24
** ON A/C NOT FOR ALL
121VUFUEL/FWD LOW LVL/WING/L46QJM22
Subtask 28-46-34-740-050-A ** ON A/C NOT FOR ALL
C. Do the Bite Test of the FLSCU (7QJ,9QJ) (Ref. AMM TASK 28-46-00-740-001).
5. Close-up
Subtask 28-46-34-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the WARNING NOTICE(S).
   (3) Close access door 811.
   (4) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.02 06:18:17 UTC