W DOC AIRBUS | AMM A320F

Removal of the Fuel-Level Sensing Control-Unit (FLSCU)


TASK 28-46-34-000-001-B
Removal of the Fuel-Level Sensing Control-Unit (FLSCU)


ZONE: 121
ZONE: 122
ZONE: 150
FIN: 47QJ ** ON A/C NOT FOR ALL
FIN: 7QJ ** ON A/C NOT FOR ALL
FIN: 9QJ ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
121
AVIONICS COMPARTMENT
122
AVIONICS COMPARTMENT
150
AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT
811
 C. Referenced Information
REFERENCE
DESIGNATION
3. Job Set-up
Subtask 28-46-34-865-056-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 7QJ (FLSCU1)
49VUFUEL/AFT LOW LVL/& OVFL/WING L43QJA10
121VUFUEL/HI/LVL/SPLY1QJL25
121VUFUEL/FWD LOW LVL/WING/R45QJM23
121VUFUEL/CTR TK/AUTO/CTL3QLR27
121VUFUEL/CTR TK/L&R XFR/CTL & IND1QLR25
FOR FIN: 9QJ (FLSCU2)
49VUFUEL/AFT LOW LVL/& OVFL/WING R44QJA11
121VUFUEL/HI/LVL/SPLY1QJL25
121VUFUEL/FWD LOW LVL/WING/L46QJM22
121VUFUEL/CTR TK/AUTO/CTL3QLR27
121VUFUEL/CTR TK/L&R XFR/CTL & IND2QLR26
FOR FIN: 47QJ (FLSCU 3)
121VUACT1/REFUEL & SPLY33QUL29
121VUFUEL/HI/LVL/SPLY1QJL25
121VUACT LOW LVL R51QJM29
121VUACT LOW LVL L52QJM28
121VUACT XFR VALVE MAN CTL30QHN29
121VUACT1/CTL & SPLY9QHP29
121VUACT PUMP SUPPLY25QHQ29
Subtask 28-46-34-010-053-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position.
   (2) Open access door 811.
   (3) On FUEL overhead panel 40VU:
  • Make sure that all the pushbutton switches are released (the OFF legends come on).
  • Put the WARNING NOTICE(S) in position to tell persons not to operate the fuel system.
   (4) On refuel/defuel control panels 800VU and 801VU, put the WARNING NOTICE(S) in position to tell persons not to refuel/defuel the fuel tanks.
4. Procedure
Subtask 28-46-34-020-052-A ** ON A/C NOT FOR ALL
A. Removal of the FLSCU
   (1) Loosen the knurled nut (4).
   (2) Remove the FLSCU (1) from its rack (2).
   (3) Put CAP - BLANKING on the electrical connectors (3) and (5).
[Rev.10 from 2021] 2026.04.02 06:18:17 UTC