Removal of the Fuel-Level Sensing Control-Unit (FLSCU)


TASK 28-46-34-000-001-A
Removal of the Fuel-Level Sensing Control-Unit (FLSCU)


ZONE: 121
ZONE: 122
FIN: 7QJ ** ON A/C NOT FOR ALL
FIN: 9QJ ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
121
AVIONICS COMPARTMENT
122
AVIONICS COMPARTMENT
811
 C. Referenced Information
REFERENCE
DESIGNATION
3. Job Set-up
Subtask 28-46-34-865-050-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 7QJ (FLSCU1)
49VUFUEL/XFR VALVE1/WING/L1QPA10
** ON A/C NOT FOR ALL
49VUFUEL/AFT LOW LVL/& OVFL/WING L43QJA10
** ON A/C NOT FOR ALL
121VUFUEL/CTR TK/AUTO/CTL47QAR27
121VUFUEL/CTR TK/PUMPS1 AND 2/CTL AND IND31QAR25
** ON A/C NOT FOR ALL
121VUFUEL/XFR VALVE2/WING/R4QPM23
** ON A/C NOT FOR ALL
121VUFUEL/HI/LVL/SPLY1QJL25
** ON A/C NOT FOR ALL
121VUFUEL/CTR TK/AUTO/CTL3QLR27
121VUFUEL/CTR TK/L&R XFR/CTL & IND1QLR25
** ON A/C NOT FOR ALL
121VUFUEL/HI/LVL/SPLY1QJL24
** ON A/C NOT FOR ALL
121VUFUEL/FWD LOW LVL/WING/R45QJM23
** ON A/C NOT FOR ALL
FOR FIN: 9QJ (FLSCU2)
49VUFUEL/XFR VALVE1/WING/R2QPA11
** ON A/C NOT FOR ALL
49VUFUEL/AFT LOW LVL/& OVFL/WING R44QJA11
** ON A/C NOT FOR ALL
121VUFUEL/CTR TK/AUTO/CTL47QAR27
121VUFUEL/CTR TK/PUMPS1 AND 2/CTL AND IND32QAR26
** ON A/C NOT FOR ALL
121VUFUEL/XFR VALVE2/WING/L3QPM22
** ON A/C NOT FOR ALL
121VUFUEL/HI/LVL/SPLY1QJL25
** ON A/C NOT FOR ALL
121VUFUEL/CTR TK/AUTO/CTL3QLR27
121VUFUEL/CTR TK/L&R XFR/CTL & IND2QLR26
** ON A/C NOT FOR ALL
121VUFUEL/HI/LVL/SPLY1QJL24
** ON A/C NOT FOR ALL
121VUFUEL/FWD LOW LVL/WING/L46QJM22
Subtask 28-46-34-010-050-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position.
   (2) Open access door 811.
   (3) On FUEL overhead panel 40VU:
  • Make sure that all the pushbutton switches are released (the OFF legends come on).
  • Put the WARNING NOTICE(S) in position to tell persons not to operate the fuel system.
   (4) On refuel/defuel control panel 800VU, put the WARNING NOTICE(S) in position to tell persons not to refuel/defuel the fuel tanks.
4. Procedure
Subtask 28-46-34-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the FLSCU
   (1) Loosen the knurled nut (4).
   (2) Remove the FLSCU (1) from its rack (2).
   (3) Put CAP - BLANKING on the electrical connectors (3) and (5).